8.1  Customer service

In case of problems that cannot be resolved 

with the aid of the troubleshooting guide in this 

installation manual, contact either:

A) The installer who supplied the product. 

B)  OSO Hotwater UK Limited: 

  Tel.: (0191) 482 0800   Fax: (0191) 491 3655 

  Email: [email protected]

9. REMOVING THE PRODUCT

9.1 Removal

A) Disconnect the power supply.

B) Shut off incoming cold water supply.

C) Empty the product of water – see section 4.4.

D) Disconnect all pipes.

E)  The product can now be removed.

9.2 Returns scheme

This product is recyclable and should be taken to 

the environmental recycling centre. If the prod-

uct is to be replaced with a new one, the installer 

can take the old cylinder away for recycling.

GUARANTEE - OSO UNVENTED HOTWATER CYLINDER

1. Scope

OSO Hotwater UK Ltd. (hereinafter called OSO) warrants for 2 

years from the date of purchase, that the Product will: i) conform 

to  OSO  specification,  ii)  be  free  from  defects  in  materials  and 

workmanship, subject to conditions below. All components carry 

a 2-year warranty. 

The warranty is voluntarily extended by OSO to 25 years for the 

stainless steel inner tank. This extended warranty only applies to 

Products purchased by a consumer, that has been installed for 

private use and that has been distributed by OSO or by a distributor 

where the Products have been originally sold by OSO.

The extended warranty does not apply to Products purchased by 

commercial entities or for Products that have been installed for 

commercial use. These shall be subject only to the mandatory 

provisions of the law. The conditions and limitations set out below 

shall apply.

2. Coverage

If a defect arises and a valid claim is received within the statutory 

warranty period, at its option and to the extent permitted by law, 

OSO shall either; i) repair the defect, or; ii) replace the product with 

a product that is identical or similar in function, or; iii) refund the 

purchase price.

If a defect arises and a valid claim is received after the statutory 

warranty period has expired, but within the extended warranty 

period, OSO will supply a product that is identical or similar in 

function. OSO will in such cases not cover any other associated 

costs. In addition, for every year after the statutory warranty period, 

the claimant must contribute 4 % of the list price of the cylinder in 

question to OSO.

Any exchanged Product or component will become the legal 

property of OSO. Any valid claim or service does not extend the 

original warranty. The replacement Product or part does not carry 

a new warranty.

3. Conditions

The Product is manufactured to suit most public water supplies. 

However, there are certain water chemistries (outlined below) that 

can have a detrimental effect on the Product and its life expectancy. 

If there are uncertainties regarding water quality, the local water 

supply authority can supply the necessary data.

The warranty applies only if the conditions set out below are met 

in full:

• 

The Product has been installed by a professional installer, in 

accordance with the instructions in the installation manual 

and all relevant Codes of Practice and Regulations in force at 

the time of installation.

• 

The Product has not been modified in any way, tampered 

with or subjected to misuse and no factory fitted parts have 

been removed for unauthorized repair or replacement. 

• 

The Product has only been connected to a domestic mains 

water supply in compliance with the European Drinking 

Water Directive EN 98/83 EC, or latest version. The water 

should not be aggressive, i.e. the water chemistry shall 

comply with the following:

 

- Chloride 

 

 

< 250 mg / L

 

- Electric Conductivity (EC) @25°C 

< 750 uS / cm

 

 -Saturation Index (LSI) @80°C   

> - 1,0 / < 0,8

 

- pH level 

 

 

> 6,0 / < 9,5

• 

The immersion heater has not been exposed to hardness 

levels exceeding 10°dH (180 ppm CaCO3). A water softener 

is recommended in such cases.

• 

Any  disinfection  has  been  carried  out  without  affecting 

the Product in any way whatsoever. The Product shall be 

isolated from any system chlorination.

• 

The Product has been in regular use from the date of 

installation. If the Product is not intended to be used for 60 

days or more, it must be drained.

• 

The immersion heater element must be removed for 

inspection on service after 5 years. The threads must be 

checked for corrosion. If signs of corrosion are evident, 

the element must be replaced. Subsequently the element 

must  be  removed  and  examined  every  3  years.  Failure  to 

do so in areas of aggressive water may result in the element 

separating from the cylinder with consequential escape of 

water.

• 

Service  and/or  repair  shall  be  done  according  to  the 

installation manual and all relevant codes of practice. Any 

replacement parts used shall be original OSO spare parts.

• 

The  Service  record  /  Benchmark  logbook  has  been 

completed and updated after each annual service. Invoices 

should be kept as proof of service.

• 

The Commissioning Checklist / Benchmark certificate has 

been completed at the time of installation.

• 

Any third-party costs associated with any claim has been 

authorized in advance by OSO in writing. 

• 

The  purchase  invoice  and/or  installation  invoice,  a  water 

sample as well as the defective product is made available to 

OSO upon request. 

Failure  to  follow  these  instructions  and  conditions  may  result  in 

product failure, and water escaping from the Product.

4. Limitations

The warranty does not cover:

• 

Any fault or costs arising from incorrect installation, incorrect 

application, lack of regular maintenance in accordance with 

the installation manual, neglect, accidental or malicious 

damage, misuse, any alteration, tampering or repair 

carried out by a non-professional, any fault arising from 

the  tampering  with  or  removal  of  any  factory  fitted  safety 

components or measures.

• 

Any consequential damage or any indirect loss caused by 

any failure or malfunction of the Product whatsoever.

• 

Any pipework or any equipment connected to the Product.

• 

The effects of frost, lightning, voltage variation, lack of water, 

dry boiling, excess pressure or chlorination procedures.

• 

The effects of stagnant (de-aerated) water if the Product has 

been left unused for more than 60 days consecutively. 

• 

Damage caused during transportation. Buyer shall give the 

carrier notice of such damage.

• 

Costs arising if the Product is not immediately accessible for 

servicing.

These warranties do not affect the Buyer’s statutory rights.

Содержание Slimline-RI 150

Страница 1: ...y OSO Hotwater AS Industriveien 1 3300 Hokksund Norway Tel 47 32 25 00 00 Fax 47 32 25 00 90 E mail oso oso no www osohotwater com Slimline RI 150 l EN SAFETY INFORMATION O M INFORMATION INSTALLATION...

Страница 2: ...4 5 S plan wiring layout 12 4 6 Y plan wiring layout 13 5 Maintenance safety and servicing 5 1 Draining flushing 14 5 2 Recommissioning 14 5 3 Safety and maintenance 14 5 4 Corrosion resistance 14 5 5...

Страница 3: ...hould be filled with water before the power is switched on Maintenance settings should only be carried out by persons over 18 years of age with sufficient understanding CAUTION The product must not be...

Страница 4: ...ssioning of the cylinder This manual gives detailed advice for installation and should be read carefully prior to fitting any unvented unit OSO Slimline cylinders are not suitable for gravity fed prim...

Страница 5: ...ently frost free position The product should be placed on a floor or wall suitable for the total weight of the prod uct when in operation See type plate The product must have a clearance for servicing...

Страница 6: ...m standing pres sure of 2 5 bar and a flow rate of 20 litres per minute with a 1 bar dynamic pressure is recommended The cylinder will operate at lower pressures and flow rates however the performance...

Страница 7: ...s tee 9 If a balanced mains pressure cold water supply is required to a shower or bidet over rim type only remove the blanking cap from the pressure reducing valve 3 and connect to the shower or bidet...

Страница 8: ...pi cally be 82 C 16 For electrical connection of the motorised valve and immersion heater please read Electrical Installation Instructions Tundish 17 Install the Tundish 6 in a vertical position withi...

Страница 9: ...low 2 port valve supplied Zone valve not supplied Automatic bypass Radiators UFH Boiler Pump flow 2 port valve supplied Mid pos valve not supplied Radiators UFH Boiler Automatic bypass S plan piping d...

Страница 10: ...ng System flushing will not be necessary under nor mal circumstances as the line strainer will prevent ingress of foreign materials however if flushing is required run at least 50 litres of water from...

Страница 11: ...torized valve To comply with regulations governing the in stallation of indirect unvented cylinders a mo torised valve must be fitted in the primary flow or return Your OSO unit has been supplied with...

Страница 12: ...10 RESE T R E S E T M2 1 2 3 4 RESE T R E S E T M2 1 2 3 4 1 2 E 2 3 1 T6360B B1 Br G O G Y 3 5 7 3 4 N L E N L E N L ST6400 Boiler Pump 3 2 1 3 2 3 2 2 2 3 1 V4043H Room thermostat Zone Valve DHW sup...

Страница 13: ...ed 6 W B1 G Y Gr O 2 3 V4073A1039 10 4 5 9 8 7 RESE T R E S E T M2 1 2 3 4 1 2 E 2 3 1 T6360B B1 O G Br G Y 3 3 1 4 N L E N L E N L ST6400 Boiler Pump 3 2 1 3 2 3 2 2 2 3 1 V4043H Room thermostat Zone...

Страница 14: ...cold water supply and open a ground floor cold tap 2 Unscrew the pressure reducing cartridge 3 Clean the filter mesh and the cartridge under running water 4 Replace cartridge ensuring that strainer is...

Страница 15: ...15 5 5 Spare parts Pressure reducing valve Cartridge Part No REDC 355030 3 bar Expansion valve Cartridge and seat Part No 214005 6 0 Bar Expansion valve Part No PREL 355030...

Страница 16: ...t When dis charge has stopped check thermal con trols and replace as necessary Cold water PRV incorrectly fitted Check and refit as required Intermittent water discharge If problem stil persists conta...

Страница 17: ...tions Check cylinder ther mostat is switch ing on off with programmer hot water on Is 2 port moto rized valve closing when cylinder reaches tempera ture Check wiring on cylinder thermostat Wiring faul...

Страница 18: ...to a roof capable of withstanding high tem perature discharges of water and 3 m from any plastics guttering system that would collect such discharges tundish visible Where a single pipe serves a numbe...

Страница 19: ...Regulations 3 Failure to install and commission this appliance to the manufacturer s instructions may invalidate the guarantee The above does not affect your statutory rights For full details on the H...

Страница 20: ...F DIFFERENT NAME DATE ADDRESS TEL No REGISTERED OPERATIVE ID CARD No IF APPLICABLE REGISTRATION DETAILS IT IS THE RESPONSIBILITY OF THE INSTALLER TO COMPLETE THIS LOGBOOK AND PASS IT ON TO THE CUSTOME...

Страница 21: ...IS THE PRESSURE REDUCING VALVE SETTING IF FITTED WHERE IS OPERATING PRESSURE REDUCING VALVE SITUATED NO YES NO YES NO bar HAS THE EXPANSION VESSEL OR INTERNAL AIR SPACE BEEN CHECKED YES NO WHAT IS THE...

Страница 22: ...al and all relevant Codes of Practice and Regulations in force at the time of installation The Product has not been modified in any way tampered with or subjected to misuse and no factory fitted parts...

Страница 23: ...ENTS SIGNATURE DATE ENGINEER NAME SERVICE 5 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 7 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 9 COMPANY NAME TEL No...

Страница 24: ...Industriveien 1 3300 Hokksund Norway Tel 47 32 25 00 00 oso oso no www osohotwater com This installation manual and all its content is protected by copyright and may be reproduced or distributed only...

Отзывы: