6
!
CAUTION
Pipe stubs, valves etc. should not be used to lift
the product as this could cause malfunctions.
3. INSTALLATION INSTRUCTIONS
3.1 Products covered by these instructions
800 0306 Delta Twincoil - DTC 200
800 0308 Delta Twincoil - DTC 300
3.1.1 Health and safety regulations
Handling Operations Regulations 1992 defines
manual handling as: “any transporting or support-
ing of a load (including the lifting, putting down,
pushing, pulling, carrying or moving thereof) by
hand or bodily force” The Regulations set no spe-
cific requirements such as weight limits. However
common sense still has to be used based on an
ergonomic approach for each individual.
The DELTA Twin Coil VIP should be transported
and stored in a vertical position.
3.3.2 Delivery
The product should be transported carefully as
shown, with packaging. Use the handles in the
box.
3.3.3 Siting the DELTA Twin Coil VIP
There are few restrictions on the siting of the
OSO DELTA Twin Coil VIP, however it should not
be sited anywhere open to frost attack. The unit
should be placed on a stable flat surface capable
of withstanding the weight of the cylinder when
full (see data plate) and access must be allowed
for maintenance purposes. Provision should
also be allowed for the routing of the discharge
pipe away from the cylinder to an outside point
according to building regulation G3.
3.4 Requirements for installation, location and
positioning
!
CAUTION
!
The product should be placed in a room with a drain, in accordance with the wetroom
standard / latest TEK. Alternatively, fit an automatic stop valve with sensor and overflow
from safety valve to drain.
!
The product should be placed in a dry and permanently frost-free position.
!
The product should be placed on a floor or wall suitable for the total weight of the product
when in operation. See type plate.
!
The product must have a clearance for servicing of 40 cm in front of the cover / 10 cm over the
top connection.
!
The product should be easily accessible in the home for servicing and maintenance.
Min.
40 cm
Min. 10 cm
Содержание Delta Twincoil DTC 200
Страница 26: ...26 NOTES ...