background image

15

Maintenance must be carried out by a compe-

tent person.

5.1 Safety cut out

 

1.  The safety cut-out operates if: 

a. Wiring is incorrect. 

b. The immersion heater thermostat or 

cylinder thermostat fails.

2.  Important: Before resetting the safety cut-

out or altering the thermostat setting, isolate 

electrical supply to the unit prior to removal 

of the electric junction box cover (2).

3.  Reduce the thermostat setting and press 

the reset button (6). After adjustments are 

completed, ensure the electric junction box 

cover (2) is refitted correctly and the retain-

ing screw is fitted.

4.  If still out of operation, contact installer.

5.2 Settings

5.2.1  Thermostat setting

The thermostats in the product are adjustable 

from 40-70°C. The thermostats should not be set 

lower than 60°C to prevent bacteria growth. 

To adjust the temperature:

A) Disconnect the power supply.

B)  Remove the junction box cover (1) by unscrew-

ing the retaining screw (2).

C) Adjust the temperature on the thermostat dial 

(7) with a screwdriver.

Changing the temperature setting on the thermo-

stat changes the temperature of the water inside 

the vessel. Increasing the temperature will result 

in a higher available hot water volume. 

The outgoing hot water temperature from the 

product to the taps will be the same as the set 

temperature of the thermostat. For temperature 

adjustment, see pt. 5.2. 

Since the water temperature in the product can 

be up to 70°C it is strongly recommended to in-

clude a mixer valve in the system to avoid danger 

of scalding. 

5.2.2  Resetting the safety thermostat

The safety thermostat on the product cuts out 

when there is a risk of overheating. This can be 

reset by disconnecting the power supply and 

removing the junction box cover - loosen the 

retaining screw (2) securing the cover (1) - see il-

lustration. Press the red “RESET” button (6). A no-

ticeable click should be heard when the thermo-

stat resets. If the thermostat cuts out repeatedly, 

contact the installer. 

The cover panel (1) must be refitted before the 

power is switched back on. 

5. USER GUIDE, SAFETY AND SERVICING

!

 WARNING

Continuous voltage is present at the terminals in the 

junction boxes. Before any electrical work is done, 

the power supply must be disconnected and secured 

against activation while the work is in progress.

RESET    

  RE

SET

M2

1

2

3

4

THERM-O-DISC

1

2

7

6

1

1

2

2

Содержание 80800277

Страница 1: ...146249 00 01 2022 Optima Geocoil OGC 300 l EN SAFETY INFORMATION O M INFORMATION INSTALLATION MANUAL TDS TECHNICAL DATA SHEET ...

Страница 2: ... 5 Requirements for installation location 8 3 6 Pipe installation 8 3 7 Electrical installation 11 4 Commissioning 13 4 1 Commissioning and filling 13 4 2 Turning on the power 13 4 3 Temperature adjustment of tap water 13 4 4 Control points 13 4 5 Draining 13 4 6 System flushing 14 4 7 Handover to end user 14 5 User guide safety and servicing 15 5 1 Safety cut out 15 5 2 Settings 15 5 3 Intermitte...

Страница 3: ... the safety valves must NOT be sealed or plugged Discharge must comply with current building regulations The electrical supply to the heater shall be done in accordance with current local regula tions and best practice by a qualified electrician The product is intended for permanent supply The mains power supply cable shall withstand 90 C A strain reliever must be fitted supplied The product shall...

Страница 4: ...12897 2016 Safety standard EN 60335 2 21 Welding standard EN ISO 3834 2 The manufacturer is certified for Quality ISO 9001 Environment ISO 14001 Work environment ISO 45001 2 2 Intended use Optima OGC is designed to deliver hot water and hydronic heat from an electrical and or external energy source The OGC 300 can be used with a heat pump fitted with a three way valve The lower part of the cylinde...

Страница 5: ...ylinder rated pressure MPa Bar 1 10 Maximum design pressure of lower cylinder rated pressure MPa Bar 0 20 2 5 Operating pressure of cylinder upper MPa Bar 3 Max operating temperature of cylinder C 70 Expansion vessel capacity L 18 Hydraulic connections Buffer connections Inch BSP female 1 Cold water Inch BSP female 3 4 Hot water Inch BSP female 3 4 Immersion heater Inch BSP female 1 1 4 Safety val...

Страница 6: ... 2 1 8 5 2 1 9 10 4 4 3 6 7 3 2 1 G3 Inlet Group kit The product is supplied with a G3 Inlet Group kit The kit contains the components shown in table below and illustration right No Description Dim A Cold water supply ø22 mm B Balanced cold supply optional ø22 mm C Expansion vessel 1 2 D Multibloc valve 3 4 E Discharge pipework 15 22 mm F Drain cock not supplied N A G Cold water inlet 3 4 int H Tu...

Страница 7: ...3 4 int thread Coil connection lower F 3 4 int thread Coil connection upper G 1 2 Safety valve lower cylinder H 3 4 int thread Cold water inlet upper cylinder I ø15 mm T P relief valve upper cylinder J ø6 ø8 mm Sensor slot K 3 4 int thread Hot water outlet L 3 4 int thread Anode A E B D C F I J K L J H G ø 30 45 15 3 4 1 Delivery The product should be transported carefully as shown with packaging ...

Страница 8: ...e installation The product is designed to be permanently connected to the mains water supply Ap proved pipes of the correct size should be used for installation The relevant standards and regulations must be followed 3 6 1 Incoming water pressure The efficiency of the product depends on the incoming cold water pressure The water pressure should be min 2 bar and max 6 bar throughout the day Excessi...

Страница 9: ...volume A Approved pipes of a suitable dimension can be fitted to coil connections 3 and 4 B Approved pipes of a suitable dimension can be fitted to buffer volume connections 5 Unused connections must be properly plugged Use a suitable thread sealant with all connec tions to avoid leaks HW outlet CW inlet Space heating High output heat source 3 6 4 Pipe fitting schematics Suggested pipe fitting lay...

Страница 10: ...sel shall be filled first Discharge must comply with current building regulations 3 6 6 Temperature sensor installation The product is equipped with two temperature sensor brackets which allows installation of 6 or 8 mm temperature sensors To install the temperature sensor follow the instructions below 1 Remove temperature sensor bracket A from tank body by gripping it and pulling straight out 2 I...

Страница 11: ...s connected to the terminal on the heating ele ment hexagonal brass D Internal wires from the element to the ther mostat are factory fitted and connected to point 4 on the safety thermostat and point 2 on the work thermostat See illustration right 3 7 1 Electrical components Component Note Safety cut out upper lower 85 C thermal cut out Safety thermostat upper box 40 70 C adjustable Work thermosta...

Страница 12: ...stalled by an authorised electrician Components for disconnection must be included in the fixed electrical installation in accordance with applicable standards and regulations Mains cable should withstand 90 C continuously A strain reliever must be fitted supplied CAUTION The product shall have a clearance for servicing of 400 mm in front of the electric junction box covers 100 mm over the highest...

Страница 13: ...ower can be switched on Turn on power switch circuit breaker 4 3 Temperature adjustment of tap water The outgoing hot water temperature from the product to the taps will be the same as the set temperature of the thermostat For tempera ture adjustment see section 5 1 1 Since the water temperature in the product can be up to 70 C it is strongly recommended to include a mixer valve in the system to a...

Страница 14: ...ord Log Book at the back of this manual Hand this installation manual over to the end user that the water in the vessel can be very hot take necessary precautions After draining close drain cock Close all open taps The vessel must be filled with water before pow er is turned on see pt 4 1 4 6 System flushing System flushing will not be necessary under normal circumstances as the line strainer will...

Страница 15: ... the temperature of the water inside the vessel Increasing the temperature will result in a higher available hot water volume The outgoing hot water temperature from the product to the taps will be the same as the set temperature of the thermostat For temperature adjustment see pt 5 2 Since the water temperature in the product can be up to 70 C it is strongly recommended to in clude a mixer valve ...

Страница 16: ...ylinder should be serviced annually as below and logbook should be updated in order to vali date warranty Logbook and service records act as warranty document For terms of warranty see Service logbook at rear of manual 5 7 Service procedure The following maintenance work has to be carried out annually by a competent person 1 Inspection of pressure temperature relief valve and expansion relief valv...

Страница 17: ...withstanding high temperature discharges of water and 3 m from any plastics guttering system that would collect such discharges tundish visible Where a single common discharge pipe serves more than one system it should be at least one pipe size larger than the largest individual dis charge pipe D2 to be connected For further information contact your Building Control Office Valve Outlet size Minimu...

Страница 18: ... installer No hot water Power supply interrupted Verify that the fuse is on the plug is plugged in to the wall contact the earth breaker has not tripped Thermostat has cut out Press the RESET button on the safety thermostat see User guide Heating element is defective Replace heating element Contact auth installer Leak in hot water pipe Verify as follows a close the mixer valve b wait 2 3 hours c f...

Страница 19: ... The pressure in the heating sys tem is too high Check the system pressure Normal operating pressure is 1 2 bar Contact auth Installer when needed The valve is defective Replace the valve Contact auth installer The heating circuit has to be refilled frequently Leak in the heating system Check all pipe couplings Turn off the power sup ply remove the lid on the junction box in the lower cylinder and...

Страница 20: ...the European Drinking Water Directive EN 98 83 EC or latest version The water should not be aggressive i e the water chemistry shall comply with the following Chloride 250 mg L Electric Conductivity EC 25 C 750 uS cm Saturation Index LSI 80 C 1 0 0 8 pH level 6 0 9 5 The immersion heater has not been exposed to hardness levels exceeding 5 dH 180 ppm CaCO3 A water softener is recommended in such ca...

Страница 21: ...ith the appropriate Building Regulations 3 Failure to install and commission this appliance to the manufacturer s instructions may invalidate the guarantee The above does not affect your statutory rights For full details on the HWA charter please visit http www hotwater org uk HEATING AND HOTWATER INFORMATION COUNCIL IT IS THE RESPONSIBILITY OF THE INSTALLER TO COMPLETE THIS LOG BOOK AND PASS IT O...

Страница 22: ...EER IF DIFFERENT NAME DATE ADDRESS TEL No REGISTERED OPERATIVE ID CARD No IF APPLICABLE REGISTRATION DETAILS IT IS THE RESPONSIBILITY OF THE INSTALLER TO COMPLETE THIS LOGBOOK AND PASS IT ON TO THE CUSTOMER FAILURE TO DO SO MAY INVALIDATE THE CYLINDER GUARANTEE APPLIANCE TIME CONTROL DETAILS MANUFACTURER MODEL CAPACITY TYPE TIME CONTROL UNVENTED PROGRAMMER litres MANUFACTURE date TIME SWITCH or ...

Страница 23: ...WHAT IS THE PRESSURE REDUCING VALVE SETTING IF FITTED WHERE IS OPERATING PRESSURE REDUCING VALVE SITUATED NO YES NO bar HAS THE EXPANSION VESSEL OR INTERNAL AIR SPACE BEEN CHECKED YES NO WHAT IS THE HOT WATER TEMPERATURE AT THE NEAREST OUTLET C bar ALL PRODUCTS YES DOES THE HOT WATER SYSTEM COMPLY WITH THE APPROPRIATE BUILDING REGULATIONS HAS THE SYSTEM BEEN INSTALLED AND COMMISSIONED IN ACCORDANC...

Страница 24: ...AME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 9 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 2 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 4 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 6 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 8 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 10 ...