Cleaning

Remove dirt or stains with lukewarm water and a 

cloth. Water may be treated with a mild cleaning 

agent. Do not use aggressive cleaning agents or 

solvents. You must disinfect surfaces regularly, 

at least after every clean. Wipe disinfection is 

preferred. The cleaning agent you use must comply 

with the manufacturers information as stated on 

the cleaning agent. If in doubt you must request 

further information.

Technical specification

 

Pump

OSKA – SeriesC Pump

Power supply: 

220~240V/50Hz, 1A

Air output: 

8 liter/min.

Pressure range: 

30 mmHg – 60 mmHg

Cycle time: 

12 min. 

Static Mode 

Alarm Reset Mode 

With normal / low pressure light

Size: 

28cm(L) x 20cm(W) x 10cm(H)

Weight: 

2.2 kg

Cushion

OSKA – SeriesC Air Cushion

Size: 

49cm(L) x 46cm(W) x 10cm(H)

Top cover:

 Dark blue bi-elastic cover with PU/

Polyester coating and zip fastening

Air cells: 

Nylon/PVC

Base: 

Nylon/PVC with foam insert 6 Air Cells

Содержание C Air Series

Страница 1: ...User Guide SeriesC Air Version 2 12 04 2022...

Страница 2: ...n 07 Troubleshooting guide 08 Waste disposal 08 Warranty 09 Safety Please read the following instructions carefully and observe the warning instructions before using the system Airflo Xiaxen Medical C...

Страница 3: ...rane pump and a cushion with 6 air cells arranged in a transverse manner The entire cell unit is encased in a cradle of visco foam The bielastic top cover and PVC outer base cover ensure stability com...

Страница 4: ...pump see 1b ensuring that the tubes are not twisted or kinked Allow space for tubes to drop freely 04 Switch on the pump power see 2 The power switch indicator should now illuminate and the pump will...

Страница 5: ...illuminate Static mode will commence in approximately 5 minutes Press the static button again to switch back to alternating mode 5 4 3 1B 2 System maintenance Maintenance at regular intervals mandato...

Страница 6: ...formation as stated on the cleaning agent If in doubt you must request further information Technical specification Pump OSKA SeriesC Pump Power supply 220 240V 50Hz 1A Air output 8 liter min Pressure...

Страница 7: ...t the hoses and re connect them in to the outlet connectors on the side of the pump Contact OSKA Service There are no leaks in the cushion Contact OSKA Service Contact OSKA Service There are no kinks...

Страница 8: ...ing inspection it is found that damages are due to wear and tear or are not subject to warranty then OSKA are empowered to claim the expenses inspection transport costs etc from the client The use of...