background image

SeriesC Air Cushion User Guide

Contents

03

 

The system

04

 

System set-up

05

 Operation

05

 

System maintenance

06

 Cleaning

06

 

Technical specification

07

 

Troubleshooting guide

08

 

Waste disposal

08

 Warranty

09

 Safety

Please read the following instructions carefully and observe the 

warning instructions before using the system.

Airflo (Xiaxen) Medical Co., Ltd.

1F, 3F, 4F, No.6, East Haijing Road, Haicang, Xiamen, Fujian, China

Emergo Europe B.V.

Prinsessegracht 20 2514 AP, The Hague, The Netherlands

REP

EC

Содержание C Air Series

Страница 1: ...User Guide SeriesC Air Version 2 12 04 2022...

Страница 2: ...n 07 Troubleshooting guide 08 Waste disposal 08 Warranty 09 Safety Please read the following instructions carefully and observe the warning instructions before using the system Airflo Xiaxen Medical C...

Страница 3: ...rane pump and a cushion with 6 air cells arranged in a transverse manner The entire cell unit is encased in a cradle of visco foam The bielastic top cover and PVC outer base cover ensure stability com...

Страница 4: ...pump see 1b ensuring that the tubes are not twisted or kinked Allow space for tubes to drop freely 04 Switch on the pump power see 2 The power switch indicator should now illuminate and the pump will...

Страница 5: ...illuminate Static mode will commence in approximately 5 minutes Press the static button again to switch back to alternating mode 5 4 3 1B 2 System maintenance Maintenance at regular intervals mandato...

Страница 6: ...formation as stated on the cleaning agent If in doubt you must request further information Technical specification Pump OSKA SeriesC Pump Power supply 220 240V 50Hz 1A Air output 8 liter min Pressure...

Страница 7: ...t the hoses and re connect them in to the outlet connectors on the side of the pump Contact OSKA Service There are no leaks in the cushion Contact OSKA Service Contact OSKA Service There are no kinks...

Страница 8: ...ing inspection it is found that damages are due to wear and tear or are not subject to warranty then OSKA are empowered to claim the expenses inspection transport costs etc from the client The use of...

Страница 9: ...e aware of the susceptibility of this air mattress to the incidence of fire In the case of a fire the unavoidable release of air acts as a fan effect to assist the flames You must avoid smoking at all...

Страница 10: ...SeriesC Air Cushion User Guide Notes...

Страница 11: ...11 Notes...

Страница 12: ...SeriesC Air Cushion User Guide Edward House 5 Penner Road Havant PO9 1QZ 02394 318 318 ask oska uk com oska uk com Pressure Care Experts...

Отзывы: