OSI Systems Rapiscan Metor 6E Скачать руководство пользователя страница 9

Page 8 

Metor 6E 

P/N 92109435 

 

 

Installation Quick Guide 

Rev. 2 

INSTALLATION 

 
 

3.1  Mechanical Assembly 

 
 

 

The items needed in mechanical assembly 
are packed in the box containing the cross 
piece.  
For checking the distance of the coil panels 
there is a pasteboard gauge in the cross 
piece box. 

Ref Part 

Pcs 

1 ............ Panel 1 (MTRP 5266)..... 1 
2 ............ Panel 2 (MTRP 5267)..... 1 
3 ............ Cross piece..................... 1 
5 ............ Mounting screws............. 8 
 Washers ......................... 8 
 Allen 

key ......................... 1 

 
The following parts illustrated in pictures are 
integrated into coil panels or cross piece, 
but they must be considered in assembly: 

Ref Part 

Pcs 

4 ............ Display and keypad ........ 1 
6 ............ Zone displays ................. 2 
 

(one in each coil panel) 

7 ............ Traffic lights .................... 1 
 

Assembly: 

 

First define the sides of the coil panels 
if you have side-by-side operation. 

 

Zone displays are assembled at factory 
so that they are towards exit side when 
panel 2 is on left side and panel 1 on 
right side. Position of the displays is 
also shown by stickers on the panels. 

 

Lay the coil panels on the floor. 

 

Install the cross piece with display and 
keypad towards the exit side. 

 

Place the cross piece to the holes in the 
coil panel and fasten using the 
mounting screws and washers. 

 

Repeat with the other panel. 

 

Do the final tightening of the screws 
after lifting the unit to ensure that the 
panels are parallel. 

 
 

 

 

Rapiscan Systems Proprietary Information 

Содержание Rapiscan Metor 6E

Страница 1: ...Rapiscan Systems 1 1 Printing instructions_A4 doc DO NOT PRINT THIS PAGE PRINT FOLLOWING DOCUMENT AS 2 SIDED COLOR PRINTING FORMAT A5 ON A4 BOOKLET FOLD AND STAPLE AT CENTER DO NOT PRINT THIS PAGE...

Страница 2: ...Installation Quick Guide Metor 6E P N 92109435 Rev 2...

Страница 3: ...f you have any questions about the content of this manual or the product that you have purchased please contact Rapiscan Systems Customer Service No Warranties The provision of this manual to you crea...

Страница 4: ...ry Information Revision History Name of Document Installation Quick Guide Metor 6E Document Number 92109435 Revision 2 Rev ECN Date Name Comments A 2013 05 20 TV Initial draft B 2013 06 06 TV Several...

Страница 5: ...ert Messages 6 1 2 Symbols used on Unit and in Manual 6 2 TECHNICAL DATA 7 3 INSTALLATION 8 3 1 Mechanical Assembly 8 3 2 Floor Fixing 10 3 3 Electrical Connections 11 3 4 Connections for Digital I O...

Страница 6: ...tions of the equipment and local safety regulations Service of Rapiscan products shall be preformed only by a Rapiscan Systems qualified service provider or authorized contractor qualified service pro...

Страница 7: ...ment Failure to follow all such warnings cautions notices and instructions may result in damage to the equipment and or injury or death to personnel Such failure may also nullify any warranties provid...

Страница 8: ...tion at standby 11 W 12 VDC Ratings of recommended external power supply Voltage nominal 100 240 VAC Voltage absolute limits 90 264 VAC Frequency nominal 50 60 Hz Recommended operating conditions Ambi...

Страница 9: ...cs 4 Display and keypad 1 6 Zone displays 2 one in each coil panel 7 Traffic lights 1 Assembly First define the sides of the coil panels if you have side by side operation Zone displays are assembled...

Страница 10: ...he cables in corresponding connectors Check that connectors lock in position Re install the top piece and fasten it with the four screws DO NOT over tighten the screws as you may damage the thread in...

Страница 11: ...holes 1 in the panel boots to fix the unit to the floor with screws If drilling holes to the floor is not preferred you can use the flat areas under the boots to attach the unit to the floor with dou...

Страница 12: ...erial port connections 4 pcs all similar for Display and keypad Traffic lights MetorNet option Remote display option 6 Digital inputs 2 pcs 7 Digital outputs 2 pcs 8 SD memory card slot 9 Ethernet con...

Страница 13: ...sistor to 12 V Maximum input voltage is 15 VDC Recommended connection is a switch that connects input pin 1 to ground pin 3 Maximum load for each relay output is 24 V and 1 A WARNING Line voltage or a...

Страница 14: ...off with button C on the keypad During standby all displays and lights are off and metal detection is disabled with magnetic field generation turned off After switching on Metor 6E runs a self test Al...

Страница 15: ...there is a 5 0AT fuse F8 protecting the electronics Fuse type is Littlefuse Nanofuse 0454005 MR part number 58105674 WARNING Replace fuse only with equivalent type to avoid risk of fire 5 3 Replacing...

Страница 16: ...l 44 0 870 777 4301 Fax 44 0 870 777 4302 U S A Customer Service Center for Canada South America Caribbean Rapiscan Systems 2805 Columbia St Torrance CA 90503 USA Tel 1 888 258 6684 toll free for US c...

Отзывы: