157
BOOM LIFT MODELS X17J
JLG
X17JR0420113
CODE DESCRIPTION
STATUS
ACTION
248
Temperature inside
battery charger too
high.
If internal temperature exceeds
80°C, battery charger reduces
power to 80%, while it stops
operating altogether if internal
temperature exceeds 90°C. Bat‑
tery charger starts at full power
again when internal tempera‑
ture falls below 70°C.
249
Battery temperature
too high.
If temperature exceeds 55°C or
is less than ‑20°C, battery char‑
ger stops working.
When battery temperature falls
below 45°C or exceeds ‑10°C
battery charger resumes nor‑
mal operation.
251
Power failure
detected.
Battery charger stops sup‑
plying power. Operation resu‑
mes as soon as alarm condi‑
tions are no longer present.
If problem persists, check
battery charger mains
power supply.
242
Error when reading
internal memory on
microcontroller.
Battery charger stops working.
Contact service dept. or
change product.
18
Extended shutdown
or power failure.
Battery charger stops sup‑
plying power. Operation resu‑
mes as soon as alarm condi‑
tions are no longer present or
after restarting.
If problem is a power failu‑
re, check battery charger
mains power supply.
245
Abnormal current
draw in primary sec‑
tion.
Battery charger stops sup‑
plying power. Operation resu‑
mes as soon as alarm condi‑
tions are no longer present.
If problem persists, contact
service dept. or change
product.
240
Digital input is open
and managed as
hardware start‑stop.
Battery charger stops charging
until digital input closes.
Close digital input.
Содержание X17J
Страница 2: ......
Страница 43: ...X17JR0420113 BOOM LIFT MODELS X17J JLG 39 ...
Страница 72: ...6 3 WORKING AREA X17JR0420113 68 BOOM LIFT MODELS X17J JLG Rotation 360 Rotation 360 ...
Страница 121: ...117 BOOM LIFT MODELS X17J JLG X17JR0420113 ...
Страница 166: ...12 2 HYDRAULIC SYSTEM DIAGRAM LITHIUM VERSION X17JR0420113 162 BOOM LIFT MODELS X17J JLG ...
Страница 170: ... LITHIUM VERSION X17JR0420113 166 BOOM LIFT MODELS X17J JLG ...