N.B.
: the CODE column indicates the CAN CODE in the message sent by the battery charger.
The normal mains voltage tolerance is the rated value ±15%.
BOOM LIFT MODELS X17J
JLG
154
X17JR0420113
CODE
MEANING
74
Driver shorted
Cause: Relay power supply fault.
Solution: Check relay power supply. This is generally a temporary problem due
to certain working conditions. If problem persists, replace inverter.
75
Driver shorted
Cause: Relay power supply fault.
Solution: Check relay power supply. This is generally a temporary problem due
to certain working conditions. If problem persists, replace inverter.
76
Coil shorted
Cause: Problem detected with relay coil.
Solution: Make sure relay coil is intact.
78
VACC not OK
Cause:
Solution: This is generally a temporary problem due to certain working condi‑
tions. If problem persists, replace inverter.
79
Incorrect start
Cause: Incorrect starting procedure.
Solution: Check electrical connections. This is generally a temporary problem
due to certain working conditions. If problem persists, replace inverter.
86
Pedal wire KO
Cause:
Solution: This is generally a temporary problem due to certain working condi‑
tions. If problem persists, replace inverter.
93
Wrong set batt
Cause: With power connected, battery test detected incorrect batteries fitted.
Solution: Replace batteries with the original ones supplied directly by Jlg Spa.
94
Current sensor KO
Cause: Set up procedure for maximum current in progress.
Solution: Contact Jlg after‑sales service.
99
Check up needed
Cause:
Solution: Contact Jlg after‑sales service.
Содержание X17J
Страница 2: ......
Страница 43: ...X17JR0420113 BOOM LIFT MODELS X17J JLG 39 ...
Страница 72: ...6 3 WORKING AREA X17JR0420113 68 BOOM LIFT MODELS X17J JLG Rotation 360 Rotation 360 ...
Страница 121: ...117 BOOM LIFT MODELS X17J JLG X17JR0420113 ...
Страница 166: ...12 2 HYDRAULIC SYSTEM DIAGRAM LITHIUM VERSION X17JR0420113 162 BOOM LIFT MODELS X17J JLG ...
Страница 170: ... LITHIUM VERSION X17JR0420113 166 BOOM LIFT MODELS X17J JLG ...