SECTION 2 - USER RESPONSIBILITIES, MACHINE PREPARATION, AND INSPECTION
3120774
– JLG Lift –
2-7
8. Mast Installation
- Mast sections properly secured, no
visible damage to mast sections, no loose or missing
parts, slide pads properly secured. Mast chains and
cables properly secured, lubricated and undamaged.
Sequencing cables properly secured and undamaged.
Sheaves and pins are properly secured, have no visible
damage, no loose or missing parts and are lubricated.
9. Platform Controls
- Up/Down and Function Enable but-
tons properly secured, no loose or missing parts, no vis-
ible damage. Placards secure and legible, emergency
shut-off button set for operation. Control markings legi-
ble; Operators manual enclosed in manual storage tube.
10. Guard Rail Installation
- All railings securely attached,
no visible damage, no missing parts; sliding entry bar in
proper working order. Platform gate working properly,
no visible sign of damage.
11. Platform Assembly
- Secure to mast; no loose or miss-
ing parts, no visible damage. Control and power cables,
no visible damage; cables properly tensioned and
seated in control cable sheaves; control cable sheaves
not damaged and rotate freely.
If equipped with side-entry platform with material tray
(OPTION), check material tray is secure to the platform
railing, no loose or missing parts, and tray locks
securely in place when raised into position.
In addition to the Daily Walk-Around Inspection, be sure to include
the following as part of the daily inspection:
Batteries Charged
Start each day with fully charged batteries.
Overall Cleanliness
Keep oil, grease, water, etc. wiped from standing surfaces and
hand holds.
Placards
Keep all information and operating placards clean and unob-
structed. Cover areas where placards are present when using the
machine for spraying paint or any material which could cover
these surfaces and reduce legibility.
Lubrication
For those parts pointed out in the Walk-Around Inspection requir-
ing lubrication,
(See “Lubrication Points (See Table 7-2. on page 7-
for specific time interval requirements.
To
order go