Section 7 - Lubrication and Maintenance
7-13
31200205
B. Element Change (as restriction indicator indicates)
If air filter restriction indicator remains on after start up or illuminates while operating
machine perform the following:
1. Unlock air cleaner cover (
6
), turn counterclockwise and remove from air cleaner
canister (
7
).
2. Remove outer primary element (
8
) and inspect for damage. Damaged elements
should not be reused.
3. Thoroughly clean the interior of the air cleaner canister and vacuator valve.
4. Replace inner safety element (
9
) after every third primary element change. If
replacing the inner safety element at this time, carefully slide the element out
and replace with new element.
5. Slide the new primary element over the inner element making sure the sealing
edge is flush with the base of the air cleaner.
6. Position air cleaner cover in place, turn clockwise and lock into position.
7. Close and secure engine cover.
Note:
An inner safety element should never be washed or reused. Always install a
new element.
Содержание JLG 3508PS
Страница 2: ......
Страница 26: ...Section 1 General Safety Practices 1 14 31200205 This Page Intentionally Left Blank...
Страница 45: ...Section 3 Controls and Indicators 3 9 31200205 This Page Intentionally Left Blank...
Страница 68: ...Section 3 Controls and Indicators 3 32 31200205 This Page Intentionally Left Blank...
Страница 85: ...Section 5 Attachments and Hitches 5 5 31200205 This Page Intentionally Left Blank...
Страница 139: ...Section 7 Lubrication and Maintenance 7 7 31200205 17M OZ2430 EVERY 8...
Страница 140: ...Section 7 Lubrication and Maintenance 7 8 31200205 50 Hour Lubrication Schedule 8 9 12 13M 2 x OZ2270 50 EVERY...
Страница 141: ...Section 7 Lubrication and Maintenance 7 9 31200205 17M OZ2440 2X 50 EVERY...
Страница 160: ...Section 8 Additional Checks 8 6 31200205 This Page Intentionally Left Blank...
Страница 174: ...Inspection Maintenance and Repair Log Date Comments...
Страница 176: ......
Страница 177: ......