SECTION 3 - CHASSIS & TURNTABLE
3-118
3121171
3.26
GENERATOR
Every 250 hours
Every 250 hours of operation, check drive belt for proper ten-
sion.
Every 500 hours
Every 500 hours of operation, service generator brushes and
slip rings. Hostile environments may require more frequent
service.
Every 500 hours of service, blow out inside of the generator. If
operating in a hostile environment, clean monthly.
Table 3-8. Coupling Port Information Table
Port
No.
Port
Size
Description
Operating
Pressure
PSI (Bar)
Proof
Pressure
PSI (Bar)
1
-12
Return
250 (17)
375 (26)
2
-10
Steer/Axle Extend
(Pressure)
3000 (207)
4500 (310)
3
-10
Drive A
5000 (345)
7500 (517)
4
-10
Drive B
5000 (345)
7500 (517)
5
-10
Drive A (Osc. Axle Lock)
5000 (345)
7500 (517)
6
-10
Drive B (Osc. Axle Lock)
5000 (345)
7500 (517)
7
-12
Case Drain
250 (17)
375 (26)