OSF 310.000.0530 Скачать руководство пользователя страница 8

PC-30 Filter control unit operating manual    Page: 8

4.

You can now use the   and   keys to set the hours. 

5.

Press the   key 

 the weekday display blinks.

6.

You can now use the   and   keys to set the weekday. 

Press the   key again to save the time. If no key is pressed for more than 
10 seconds during setting, the last time displayed is saved automatically 
and the normal operating display will be shown again.

Programming the timer

Use the   key to program the built-in timer, whereby the switch-on time and 
the associated switch-off time must always be entered as pairs.

1.

Press the   key 

 the display shows 

-----

1.

, if no switching time 

has yet been programmed.

2.

If you press one of the   or   keys, or if a switching time has already 

been programmed, the display shows 

0:00

0:00

1.

, the minute display of 

the top time (switch-on time) blinks. Note: if you press the     key, the 
current time will be taken over.

3.

You can now use the   and   keys to set the required switch-on time 

minutes. 

4.

Press the   key again 

 the hours in the switch-on time blink

5.

You can now use the   and    keys to set the required switch-on time 

hours. 

6.

Press the   key again 

 the minutes in the switch-off time blink

7.

You can now use the   and    keys to set the required switch-off time 

minutes. Note: if you press the   key, the current time can be taken over, 
if you press the     and     keys simultaneously the switch-on time set 
previously will be taken over.

8.

Press the   key again 

 the hours in the switch-off time blink

9.

You can now use the   and    keys to set the required switch-off time 
hours. 

10.Further switching times can now be programmed as in points 1-9.

11.

Press the   key again to save the switching time. If no key is pressed 
for   more   than   10   seconds   during   setting,   the   last   switching   time 
displayed is saved automatically and the normal operating display will be 
shown again.

If switching times have already been programmed, you can use the   key 
to delete them.

1.

Press   the     key   as   often   as   required   until   the   switching   time   to   be 

deleted is displayed 

10:00

16:00

3.

2.

The   switching   time   is   deleted   if   you   press   the     and     keys 
simultaneously.

.

Содержание 310.000.0530

Страница 1: ...easier to deal with Terminals for electronic level regulation NR 12 TRS 2 Art No 3030075020 enable convenient automatic regulation of the swimming pool water level The filter pump is also additionally...

Страница 2: ...8 Programming backflushing 9 Info key 9 Balancing the temperature controller 9 Fuses 10 Service terminal 10 Filter unit operating mode 10 Heater operating mode 11 Water temperature 11 Solar temperatur...

Страница 3: ...ce must be powered via a multi pole main switch with a contact opening width of at least 3mm and a residual current circuit breaker with IFN 30mA The device must be isolated before opening the housing...

Страница 4: ...on reservoir 11 12 13 14 11 1213 14 U3 N R cksp lventil 230V max 400W EUROTRONIK 10 2 3 4 5 2 3 4 5 Backflushing controller U4 N Klarsp lventil 230V max 400W Bar valves 230V can be connected for backf...

Страница 5: ...into the piping system The sensor polarity is as required A solar temperature sensor Art No 3100000030 can additionally be connected to terminals 32 and 33 optional The temperature sensor is supplied...

Страница 6: ...EUROTRONIK 10 or the NR 12 TRS 2 level regulation system Back flush The filter pump is switched on because backflushing is taking place using the bar valve connected Rinse The filter pump is switched...

Страница 7: ...shows 24 5 Water C 2 Use the and keys to set the required temperature between 0 C and 40 C 3 Press the key again to save the required temperature If no key is pressed for more than 10 seconds during...

Страница 8: ...on time minutes 4 Press the key again the hours in the switch on time blink 5 You can now use the and keys to set the required switch on time hours 6 Press the key again the minutes in the switch off...

Страница 9: ...sf PC30 ver 1 00 After this you can press the INFO key again to call up the following information 1 Time 2 Solar temperature 3 Water temperature 4 Filter pump operating status 5 Solar heater operating...

Страница 10: ...mains Once the control system has been switched on the service terminal display shows the first 4 lines of the diagnosis text e g Filter operation Temp reached Water 23 0 Solar 38 4 Filter unit operat...

Страница 11: ...perature is below the set temperature and the collector is warmer than the swimming pool water Frost hazard The heater is switched on in frost protection operating mode Water temperature The current w...

Страница 12: ...e saved automatically A temperature difference of 3 is set at the works Solar additional temperature This line displays by how much the swimming pool set temperature may be exceeded during solar heati...

Страница 13: ...s 3 If you press the key again the normal diagnosis display appears and the filter unit continues to operate The adjusted value will be saved automatically The time set here only influences the temper...

Страница 14: ...is line displays the total operating hours for the additional heater Solar operating time This line displays the total operating hours for the solar heater Backflushing counter internal This line disp...

Страница 15: ...mp and the additional heater are switched on automatically If the priority circuit is displayed in the top line of the service terminal it can be switched on or off 1 Once the key has been pressed the...

Страница 16: ...p on and the key to switch it off 3 If you press the key again the normal diagnosis display appears and the filter unit continues to operate Solar operation When the solar heater operating status is d...

Страница 17: ...display appears and the filter unit continues to operate Backflushing valve When the backflushing valve operating status is displayed in the top line of the service terminal it can be switched manual...

Страница 18: ...e switched over 1 If you press the key the following is displayed Language selection German English 2 Now use the and keys to change the selected language 3 If the key is pressed once again the normal...

Отзывы: