III. How to Use 

 

A. Self-calibration 

 

The product may require a quick self-calibration before being used for the 

first time to ensure accuracy. 

 

1. Place product on stable, flat, solid, non-slippery surface (no carpet). 

2. Step on measurement platform. Weight will be displayed on screen. 

3. Step off from measurement platform. After product turns off 

automatically after a short period of time, self-calibration is complete. 

 

B. Conducting measurement 

 

 

Place product on stable, flat, solid, 

non-slippery surface (no carpet). To 

ensure accuracy, we recommend 

performing self-calibration if product is 

moved. 

 

Open o'care app on smartphone and 

log-in. Results will be automatically 

transferred after measurement, so it is 

important to select the correct user. 

 

Stand on product for measurement. Try to 

stand as still as possible. Weight result will 

appear on screen. After weight is 

measured, device will measure heart rate 

(~15 seconds). 

 

 

After measurement completion, screen will 

alternate display of weight and heart rate. 

Product will send results to smartphone. 

(please open o'Care app prior to 

measurement, to allow product to 

automatically pair and sync) 

 

After result transfer is complete, product 

automatically shut down. 

 

Содержание BHG-208

Страница 1: ...1 User Manual BHG 208 Cardio Scale Please keep the instruction manual at hand all the time for future reference...

Страница 2: ...is user manual is protected by international copyright law All content is licensed and usage is subject to written authorization from Charder Electronic Co Ltd hereinafter Charder Charder is not liabl...

Страница 3: ...escription 6 A Overview 6 B Inserting Batteries 7 III How to Use 8 A Self calibration 8 B Conducting measurement 8 IV Caring for your product 10 A Use Storage 10 B Service and maintenance 10 V Trouble...

Страница 4: ...le flat solid non slippery surface Place the product in an area free from direct sunlight heating equipment high humidity or extreme temperature change Never submerge in water Usage on soft surfaces e...

Страница 5: ...ice with operational Bluetooth and Wi Fi is required to download the o Care app and retrieve measurement results from the product QR Code QR Code Google Play Android Devices App Store Apple Devices Af...

Страница 6: ...6 II Product Description A Overview 1 LED screen 2 Measurement platform 3 Feet 4 Battery cover...

Страница 7: ...over Insert 3 AAA batteries Replace battery cover NOTE Ensure batteries are inserted in correct orientation If batteries are inserted incorrectly product will not function If product will not be used...

Страница 8: ...no carpet To ensure accuracy we recommend performing self calibration if product is moved Open o care app on smartphone and log in Results will be automatically transferred after measurement so it is...

Страница 9: ...results 1 If o care app is not open on smartphone results will not be transferred Product will automatically shut down 30 seconds after completion of heart rate measurement 2 Ensure that Bluetooth is...

Страница 10: ...o not use detergents or cleaners to clean the product This may damage the coating protecting the electrodes used for body composition measurement Wipe the platform and display using clean soft cloth A...

Страница 11: ...s product s maximum capacity Stay still and avoid movement during measurement Data transfer error Data sent from smartphone to product resulted in error Try measurement again Data transfer error Data...

Страница 12: ...Product 290 W x 300 D x 25 H mm Screen 76 W x 42 5 D mm Operation Environment Temperature 5 35 Relative Humidity 30 85 Storage Environment Temperature 20 60 Relative Humidity 10 95 Capacity Graduatio...

Страница 13: ...ations flicker emissions IEC 61000 3 3 Compliance Guidance and manufacturer s declaration electromagnetic immunity The BHG 208 Cardio Scale is intended for use in the electromagnetic environment speci...

Страница 14: ...the electromagnetic environment specified below The customer or the user of the product should assure that is used in such an environment Immunity test IEC 60601 test level Compliance level Electroma...

Страница 15: ...rtable and mobile RF communications equipment and the BHG 208 Cardio Scale The product is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The custom...

Страница 16: ...sion Yangzhou Co Ltd No 28 Xinyang Rd Development Zone Yangzhou City Jiangsu Province 225009 P R China on behalf of Charder Electronic Co Ltd No 103 Guozhong Rd Dali Dist Taichung City 412 Taiwan R O...

Отзывы: