Device Features
12
PIN No.
RS485 IN Terminal Signal RS485 OUT Terminal Signal
1,2
GND
GND
3 Tx-
Tx-
4
Rx+
Rx+
5 Rx-
Rx-
6
Tx+
Tx+
7,8 NC
NC
4.
Ethernet (RJ-45)
It is used to connect with a computer to access the network control page
or run the device control tool to modify the network settings, set up a
network system, or update the software of the device.
5.
Dip switch
There is a Dip switch both in the rear panel of remote control panel and
router, which is used to configure the address of these units.
The Dip switch has 8 bits, numbered from 1 to 8 in sequence, from lower
bit to higher bit, as shown in Figure 4.1-5:
Figure 4.1-5 Dip switch
The lower 4 bits are reserved, and the higher 4 bits are used to restore the
factory originals.
The default IP addresses of router is 192.168.1.86.
The formula of device address:
The device address
=
2
0
*K1+2
1
*K2+2
2
*K3+2
3
*K4
Thereinto, Ki=0 represents the “i” bit is at the position of ON, Ki=1
represents the “i” bit is at the position of OFF ( the opposite direction of
ON), i=1~4.