background image

  XMP300

OWNER’S MANUAL 

1.    

Power Switch 

  Switches   the   

XMP300

  on   or   o f f.  A  red LED indicates connection to AC power 

while in standby mode. Turns green indicating audio signal is present.  

2.   

Speaker Selector 

         Selects speaker zone A or B. For A + B zones push both buttons in.  

3.   

Balance 

      Fades speaker output between the Right and Left Channels 

4.   

V olume 

      Adjusts amplifier volume.       

FRONT  P ANEL CONTROLS 

7.  

Interupting Line Input 

This is the secondary input, use MAIN IN for your main input.  

INTERRUPTING INPUT can be used if a second source is desired and   

takes over when signal is present and has at least a 5mV level. 

When there is no signal, or a signal with less than 5mV level, the amp 

switches back to MAIN IN after a brief delay. 

  

8.  

10.  

 Main Input/Output 

  

11.  

12.  

Mode Select Switch 

Switches the amplifier from Stereo mode to Bridged mode.  

13.  

14.  

AUTO ON Select Switch 

Power can be turned on and off manually via the switch on the front panel 

or automatically by signal sensing.  Set it to NORMAL for manual power on/off. 

  

Set to AUTO for signal sensing; the amp will turn on when audio signal is 

detected at the inputs. NOTE: The front panel power switch must be in the 

ON position (pushed in) for the AUTO ON featu 

e to operate. 

    

Speaker Zone A Output 

Speaker output terminals for zone A. Minimum impedance: 8 ohm bridged 

or 4 ohm stereo. 

Speaker Zone B Output 

Speaker output terminals for zone B. Minimum impedance: 8 ohm bridged 

or 4 ohm stereo. 

 Power Cord 

This amplifier is configured for operation at 115V (North America). A fuse 

  

located internally protection from fault conditions. Refer to qualified 

service personel should this need to be replaced.   

REAR PANEL CONTROLS 

Figu r e 1. F r ont Panel 

4

3

2

1

6

9

11

13

Figu r e 2. Rear Panel 

Connect 

Receiver 

Here 

12

MAIN IN should be used as the “primary” or main input for the amplifier. 

Connect your receiver or main source to this input. Use MAIN OUT to pass  

MAIN IN signal to another amplifier.  

If you will be connecting one or two pair of speakers to the amplifier, place 

the switch in the “Stereo” position. NOTE: For playing 2 pairs of speakers  

(A plus B), make sure each speaker has an impedance of 8 ohms or greater.   

When set to “Bridged” mode, the amplifier is a single channel mono amplifier. 

NOTE: 

The XMP300 supplies 450W in bridged mode, Please verify that your

  

speakers are capable of handling such power to avoid possible damage! 

For stereo output connect the speaker’s positive (red) terminal to the amplifier’s 

positive (red) terminal, and the speaker’s negative (black) terminal to the  

amplifier’s negative (black) terminal for each Right and Left speaker.  

NOTE:

 To prevent sonic degradation in your speaker installation, total speaker 

wire resistance should be kept below 0.5 ohms. This table lists recommended  

speaker wire gauge versus wire run length. 

Place the “MODE” switch in the “BRIDGED” position and use both red  

terminals to connect to the speaker. Connect the speaker’s positive (red) 

terminal to the amplifier’s red (+) terminal noted next to the bridging mark, and  

the speaker’s negative (black) terminal to the amplifier’s unmarked positive  

   

NOTE:

 Only one zone (A or B) can be bridged. Do not attempt to bridge both 

A and B speaker terminals! This may result in a lower impedance than the 

  

  

amplifier is designed for and may damage your amplifier. The minimum  

impedance for the total load connected in bridged mode is 8 ohms. 

STEREO MODE 

BRIDGED MODE 

BRIDGED MODE- MONO APPLICATION 

For bridged mode, playing Right and Left together as mono output, plug 

  

RCA cables in to Right and Left RCA at MAIN input.  

Set the MODE switch to BRIDGED and follow the instructions 

for bridged speaker connection in the SPEAKER TERMINALS section of 

this manual. 

50’ or less - 16 Gauge 2-Cond. CL3 Rated 
50’ - 150’ - 12 Gauge 2-Cond. CL3 Rated 
150’ - 200’ - 10 Gauge 2-Cond. CL3 Rated 

SPEAKER TERMINALS - STEREO MODE 

SPEAKER TERMINALS - BRIDGED MODE 

6.  

Bass and Treble Controls 

These controls can adjust bass and treble frequ/- 12dB at 100Hz 

and 10kHz. 

7

9.  

 12V Trigger 

Allows the XMP300 to be powered on by other electronics or to power

on other electronics via a 3.5mm mini phone plug cable. 

10

8

(red) terminal.   

NOTE:

 Use Class 2 wiring for speaker connections.  

To wire the output connector: 1. Strip the insulation off each speaker wire to 

expose 3/8" (10 mm) of bare conductor. 2. Unscrew the output terminal binding 

post several twists, insert each wire into the correct terminal. 3. Tighten binding 

post by twisting clock-wise until it is firmly clamping the speaker wire.  

Warning: While the amplifier does self-protect under most improper output 

conditions, misconfiguration of loudspeaker mode and incorrect connection of 

loudspeakers could damage connected loudspeakers and/or amplifier. 

Please refer installation to a qualified installation professional, and always 

check state and local electrical codes when installing. 

775 Columbia St.,Brea. CA 92821 

Содержание XMP300

Страница 1: ...and accessories please visit www osdaudio com XMP300 Digital Stereo Power Amplifier FEATURES MAIN INTERRUPT priority input switching MAIN auxiliary output Speaker A B switching Front panel Balance and Volume controls Signal sensing Power On and Trigger mode SPECIFICATIONS Stereo 8 ohm 150W x 2 1 THD N Stereo 4 ohm 300W x 2 1 THD N Bridged Mono 8 ohm 450W 1kHz 1 THD N Frequency Response 10Hz 30kHz ...

Страница 2: ...t No open flame sources such as lighted candles should be placed on the apparatus 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or third prong is provided for your safety If the provided plug does not fit into your outlet consult...

Страница 3: ...ling such power to avoid possible damage For stereo output connect the speaker s positive red terminal to the amplifier s positive red terminal and the speaker s negative black terminal to the amplifier s negative black terminal for each Right and Left speaker NOTE To prevent sonic degradation in your speaker installation total speaker wire resistance should be kept below 0 5 ohms This table lists r...

Страница 4: ... defects in materials and workmanship for a limited period of time For a period of two years from date of original purchase we will repair or replace the product at our option without charge for parts and labor Customer must pay all parts and labor charges after the limited warranty period expires The limited warranty period for factory refurbished products expires after ninety 90 days from date o...

Отзывы: