17
3.
Install the middle and rear secondary air tubes ensuring air holes face forward. Install the cotter pins
as in fig 3.4.
Figure 3c
Baffle installation & removal
All firebrick and vermiculite baffles must be properly in place for correct burning operation. Have any
damaged firebricks replaced. Check the firebricks annually for damage and replace if they are broken or
damaged. See Figure 3d for the firebrick layout. Install the side & back firebricks first, and then the bottom
firebricks.