![Osburn MATRIX OB02032 Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/osburn/matrix-ob02032/matrix-ob02032_installation-and-operation-manual_1655230031.webp)
Page 31
Installation and Operation Manual - Matrix
ENGLISH
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
14 ½" (368 mm)
11" (279 mm)
A
6" (152 mm)
6" (152 mm)
B
17" (432 mm)
16" (406 mm)
B
17" (432 mm)
16" (406 mm)
C
10" (254 mm)
10" (254 mm)
C
7" (178 mm)
7" (178 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
13
FROM PIPE CONNECTOR WITH
SINGLE WALL PIPE CONNECTOR
DISTANCES
13
FROM PIPE CONNECTOR WITH
DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
D
18" (457 mm)
14 ½" (368 mm)
D
9 ¼" (235 mm)
9 ¼" (235 mm)
E
26 ½" (673 mm)
25 ½" (648 mm)
E
26 ¼" (667 mm)
25 ¼" (641 mm)
F
19 ¾" (502 mm)
19 ¾" (502 mm)
F
16 ½" (419 mm)
16 ½" (419 mm)
8.1.1 Clearances with heat shield AC02710
14
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
13
FROM DOUBLE WALL PIPE
CONNECTOR
Canada
USA
Canada
USA
A
3" (76 mm)
3" (76 mm)
D
6 ¼" (159 mm)
6 ¼" (159 mm)
B
4" (102 mm)
4" (102 mm)
E
13 ¼" (337 mm)
13 ¼" (337 mm)
C
3" (76 mm)
3" (76 mm)
F
12 ½" (318 mm)
12 ½" (318 mm)
8.1.2 Clearances With Lowered Ceiling
APPLIANCE CLEARANCESWITH SINGLE
WALL PIPE CONNECTOR
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
14 ½" (368 mm)
11" (279 mm)
A
9" (229 mm)
9" (229 mm)
B
19" (483 mm)
18" (457 mm)
B
19" (483 mm)
19" (483 mm)
C
10" (254 mm)
10" (254 mm)
C
7" (178 mm)
7" (178 mm)
L
77" (196 cm)
77" (196 cm)
L
77" (196 cm)
77" (196 cm)
13
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.
14
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe
connector to be used as close as 6" from combustible materials must be used. Only in this case, the same clearances as a certified double wall
pipe connector can be used.