Osburn MATRIX OB02032 Скачать руководство пользователя страница 3

Page 3

Installation and Operation Manual - Matrix

ENGLISH

As one of North America’s 
largest and most respected 
wood stove and fireplace 
manufacturers, Stove Builder 
International takes pride in the 
quality and performance of all 
its products. 

The following pages provide 
general advice on wood 
heating, detailed instructions 
for safe and effective 
installation, and guidance 
on how to get the best 
performance from this stove.

It is highly recommend that 
this wood burning hearth 
product be installed and 
serviced by professionals who 
are certified by a «Qualified 
Agengy» such as NFI (National 
Fireplace Institute®) or CSIA 
(Chimney Safety Institute of 
America) in the United States 
and in Canada by WETT 
(Wood Energy Technology 
Transfer) or in Quebec 
by APC (Association des 
Professionnels du Chauffage).

Contact local building or fire 
officials about restrictions 
and installation inspection 
requirements in local area.

A building permit might be 
required for the installation of 
this stove and the chimney 
that it is connected to. It 
is also recommended to 
inform your home insurance 
company.

Please read this entire manual 
before installing and using this 
stove. 

A primary alternative heat 
source should be available in 
the home. This heating unit 
may serve as a supplementary 
heat source. The manufacturer 
cannot be responsible for 
additional heating costs 
associated with the use of an 
alternative heat source.

ONLINE WARRANTY REGISTRATION

If the unit requires repairs during the warranty period, proof of purchase must be provided. The 
purchase invoice must be kept. The date indicated on it establishes the warranty period. If it 
can not be provided, the warranty period will be determined by the date of manufacture of the 
product.

It is also highly recommended to register the warranty online at

https://www.osburn-mfg.com/en/warranty/warranty-registration/

Registering the warranty will help to quickly find the information needed on the unit.

THANK YOU FOR CHOOSING 
THIS WOOD STOVE.

If this stove is not 
installed properly, 
combustible materials 
near it may overheat 
and catch fire.

 

 

To reduce the 
risk of fire, follow 
the installation 
instructions in this 
manual. 

Содержание MATRIX OB02032

Страница 1: ...ALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN LOCAL AREA READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD STOVE FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT I...

Страница 2: ......

Страница 3: ...stove and the chimney that it is connected to It is also recommended to inform your home insurance company Please read this entire manual before installing and using this stove A primary alternative h...

Страница 4: ...Tree Species 14 3 2 Log Length 15 3 3 Piece Size 15 3 4 Compressed Wood Logs 15 3 5 Drying Time 15 4 Stove Operation 17 4 1 Pedestal Wood Storage 17 4 2 Fire Screen 17 4 3 Blower Operation 18 5 Burnin...

Страница 5: ...2 Suitable Chimneys 36 9 3 Minimum Chimney Height 38 9 4 Chimney Location 38 9 5 Supply of Combustion Air 39 9 6 Chimney Connector 40 Appendix 1 Side Panels Installation 42 Appendix 2 Top Panels Inst...

Страница 6: ...Page 6 Installation and Operation Manual Matrix ENGLISH CERTIFICATION PLATE...

Страница 7: ...opening the loading door NEVER USE GASOLINE LANTERN FUEL NAPHTHA FUEL OIL MOTOR OIL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS OR AEROSOLS TO START A FIRE IN THIS STOVE KEEP ALL SUCH LIQUIDS...

Страница 8: ...ting area and maximum burn time may vary subject to location in home chimney draft heat loss factors climate fuel type and other variables The recommended heated area for a given appliance is defined...

Страница 9: ...7 10 North south ends of the logs visible East west sides of the logs visible 11 Mobile homes Canada or manufactured homes USA The US Department of Housing and Urban Development describes manufactured...

Страница 10: ...Dimensions 27 1 4 692mm 25 1 2 648mm 12 3 4 324mm 5 3 4 145mm 6 150mm Figure 1 Top view 15 3 4 400mm 9 3 4 248mm 24 1 4 616mm 8 3 4 222mm 20 3 4 528mm 2 3 4 70mm 23 5 8 600mm 24 609mm 24 3 8 618mm 20...

Страница 11: ...ation and Operation Manual Matrix ENGLISH 8 202mm 17 1 4 438mm 21 533mm Figure 4 Door opening Figure 5 Front view Combustion chamber 3 16 5mm 11 7 8 301mm 16 3 4 423mm 5 16 8mm Figure 6 Side view Comb...

Страница 12: ...e back in an East West orientation Place a medium log about 3 x 3 on top of the biggest one Place another medium on coal bed on front of the biggest with another medium on top of it Place the last med...

Страница 13: ...s sand and quartz that are combined in such a way to form a high temperature glass Ceramic glass cannot be recycled in the same way as normal glass so it should not be disposed of with your regular ho...

Страница 14: ...d is in the correct moisture content range of 15 to 20 Refer to the following section of suggestions on preparing fuelwood and judging its moisture 3 Fuel Good firewood has been cut to the correct len...

Страница 15: ...y were fed large pieces of hardwood 3 2 Log Length Logs should be cut at least 1 25 mm shorter than the firebox so they fit in easily Pieces that are even slightly too long makes loading the stove ver...

Страница 16: ...eather than in winter weather Split pieces dry more quickly than unsplit rounds Softwoods like pine spruce poplar and aspen take less time to dry than hardwoods They can be dry enough to burn after be...

Страница 17: ...cations are met The logs must never exceed the inside edge A of the pedestal The heat shield B under the firebox must not be removed No combustible material may be placed over the heat shield B 16 3 4...

Страница 18: ...ill make the blower start automatically when the stove is hot enough and will stop it when the stove has cooled down Therefore the blower variable speed control can be left at the desired setting OFF...

Страница 19: ...osite of the conventional method and only works properly if well seasoned wood is used Place three or four small split dry logs in the firebox Arrange the kindling wood on the logs in two layers at ri...

Страница 20: ...is inactive A cycle begins when a new load of wood is ignited by the hot embers and ends when it is consumed and only remains embers the size of those found in the firebox when the wood has been added...

Страница 21: ...firebox since it will affect the proper operation of the appliance The best time to remove ash is in the morning after an overnight fire when the heater is relatively cold but there is still a little...

Страница 22: ...in the firebox and lay two more across them in the other direction Open the air control fully and only reduce the air after the wood is fully flaming This kind of fire is good for mild weather and sho...

Страница 23: ...demand for space 5 7 5 Logs Orientation In a relatively square firebox the wood can be loaded north south ends of the logs visible or east west sides of the logs visible North south loads allow more w...

Страница 24: ...ditions the door glass should stay relatively clear If the firewood is dry enough and the operating instructions in this manual are followed a whitish dusty deposit will form on the inner surface of t...

Страница 25: ...ss gasket is flat adhesive backed woven fibreglass 1 Follow the steps of the previous section to remove the glass Remove the old gasket and clean the glass thoroughly 2 Peel back a section of the pape...

Страница 26: ...2 Gasket It is important to replace the gasket with another having the same diameter and density to maintain a good seal 1 Remove the door and place it face down on something soft like a cushion of r...

Страница 27: ...e risk of a chimney fire 6 6 Frequency It is not possible to predict how much or how quickly creosote will form in the chimney It is important therefore to check the build up in the chimney monthly un...

Страница 28: ...sites Mixing of appliance components from different sources or modifying components may result in hazardous condtions Where any such changes are planned the manufacturer should be contacted in advanc...

Страница 29: ...liant installation In addition you will find information about your stove model serial number etc The certification label can be found on the back of the stove It is recommended to note the stove seri...

Страница 30: ...Page 30 Installation and Operation Manual Matrix ENGLISH A B E D CAN 48 122 cm US 36 92 cm F F C Figure 10 Clearances Top Figure 11 Clearances Corner 84 L 213 cm Ve Ho N Figure 12 Clearances Side...

Страница 31: ...FROM DOUBLE WALL PIPE CONNECTOR Canada USA Canada USA A 3 76 mm 3 76 mm D 6 159 mm 6 159 mm B 4 102 mm 4 102 mm E 13 337 mm 13 337 mm C 3 76 mm 3 76 mm F 12 318 mm 12 318 mm 8 1 2 Clearances With Lowe...

Страница 32: ...FROM PIPE CONNECTOR WITH DOUBLE WALL PIPE CONNECTOR Canada USA Canada USA A 9 229 mm 9 229 mm D 12 311 mm 12 311 mm B 19 483 mm 19 483 mm E 28 718 mm 28 718 mm L 77 196 cm 77 196 cm 8 1 5 Clearances F...

Страница 33: ...board brick or any other approved or listed material suited for floor protection No R factor is required Any type of tile will require a continuous non combustible sheet underneath to prevent the poss...

Страница 34: ...ERCENTAGES SIDES AND REAR TOP CEILING CAN USA USA MIN CAN USA USA MIN Sheet metal a minimum of 24 gauge 0 61 mm in thickness spaced out at least 1 25 mm 21 mm in Canada by non combustible spacers 67 1...

Страница 35: ...inimum clearance between the appliance top and an unshielded combustible ceiling 40 1035 mm B Shield extension above the appliance 20 500 mm C Minimum space behind the shield 1 25 mm In Canada 21 mm D...

Страница 36: ...er of at least 5 130 mm Canada only or no more than 7 180 mm is permitted if it allows the proper evacuation of flue gases and that such application is verified and authorized by a qualified installer...

Страница 37: ...e install a mobile home roof flashing and seal it with silicone 9 2 3 Masonry Chimney The stove may also be connected to a masonry chimney provided the chimney complies with the construction rules fou...

Страница 38: ...RIDGE 9 4 Chimney Location Because the venting system is the engine that drives the wood heating system it must have the right characteristics The signs of bad system design are cold back drafting whe...

Страница 39: ...is not affected by wind pressures on the house Contrary to commonly expressed concerns almost all tightly sealed new houses have enough natural leakage to provide the small amount of air needed by the...

Страница 40: ...double wall pipe installed between the stove flue collar and the chimney breech Double wall chimney connectors are tested and certified The rules concerning installation are found in the manufacturer...

Страница 41: ...m Galvanized flue pipes must not be used because the coatings vaporize at high temperatures and release dangerous gases Use black painted flue pipes Flue pipes must be at least 24 gauge in thickness...

Страница 42: ...e the top of the stove 2 Slightly unscrew without removing the screws B holding the panel stone brackets on each side at the front and back of the unit 3 For panels installation insert the decorative...

Страница 43: ...Installation and Operation Manual Matrix ENGLISH 4 Tighten all the screws C previously unscrewed to hold the decorative assemblies 5 Reinstall stove top See Step 1 and install top panels See Appendix...

Страница 44: ...l Matrix ENGLISH Appendix 2 TOP PANELS INSTALLATION Steel Panel Cut the gasket A to the correct lenght and stick it on the stove as shown below Lay the steel panel down on the stove Soap Stone Panels...

Страница 45: ...Page 45 Installation and Operation Manual Matrix ENGLISH Appendix 3 LOG RETAINERS INSTALLATION 1 2 3...

Страница 46: ...e HVAC type must comply with ULC S110 or UL 181 class 0 or class 1 must be connected to the rear of the appliance with two collars A sold separately The duct must also be connected to an outside air i...

Страница 47: ...the door opening 3 Lean the upper part of the fire screen against the top door opening making sure to stove the top fire screen brackets behind the primary air deflector 4 Lift the fire screen upwards...

Страница 48: ...d stove It allows the blower to operate only when the stove is hot enough See the instructions provided with the thermodisc for more details B A Screw the thermodisc A on the back of the stove with th...

Страница 49: ...end of the tube into the rear left channel 2 Align the notch in the left end of the tube with the key of the left air channel hole Using a Wise grip hold the tube and lock it in place by turning the t...

Страница 50: ...Page 50 Installation and Operation Manual Matrix ENGLISH Note that secondary air tubes B can be replaced without removing the baffle board A and that all tubes are identical A B...

Страница 51: ...TAIL E 2 3 5 4 6 10 12 7 9 4 14 48 47 45 49 32 15 16 17 17 18 23 21 25 24 35 34 33 20 D DETAIL D 28 29 30 38 21 41 42 43 44 50 26 19 22 52 54 53 55 56 53 70 71 21 65 65 64 67 67 67 66 67 67 67 67 67 6...

Страница 52: ...HINGE 1 14 30117 SOCKET SET SCREW 10 32 X 1 4 4 15 SE23051 GLASS WITH GASKET 20 1 4 W X 12 1 2 H 1 16 AC06400 3 4 FLAT X 6 BLACK SELF ADHESIVE GLASS GASKET 1 17 PL65646 GLASS FRAME 2 18 SE53585 GLASS...

Страница 53: ...n 1 54 44070 CROSSFLOW BLOWER SINGLE CAGE 130 CFM 115V 60Hz 56W 1 55 AC02055 QUICK CONNECT THERMODISC KIT 1 56 44028 CERAMIC THERMODISC F110 20F 1 57 OA10701 SOAPSTONE SIDE PANEL KIT 1 58 PL65668 BOTT...

Страница 54: ...e to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refundi...

Страница 55: ......

Страница 56: ...l com This document is available for free download on the manufacturer s website It is a copyrighted document Resale is strictly prohibited The manufacturer may update this document from time to time...

Отзывы: