OSAKA OPERATING INSTRUCTIONS –COC 30- Page 

12

 

 

6 – PROBLEMS, MAINTENANCE AND GUARANTEE

 

 
6.1 - ERROR SIGNALLING 

Errors

 

Motivo

 

Acción 

 

E1, E2, 

E3, E4

 

Probe error 

Verify the correct 
connection between 
probe  and instrument 
and then  verify the 
correct functioning of the 
probe  

u1, u2, 

u3, u4

 

The measured 
variable  is under the 
probe’s  limits (under-
range)  

o1, o2, 

o3, o4

 

The measured 
variable  is over the 
probe’s  limits (over-
range)  

Verify the correct 

connection between 

probe 

ErE

 

Possible anomaly of 
the EEPROM memory 

Push key “P” 

 
In probe error conditions, the instrument provides to disable 
the control outputs and activate the alarms. 
 

6.2 - CLEANING 

We recommend cleaning of the instrument with a slightly wet 
cloth using water and not abrasive cleaners or solvents which 
may damage the instrument. 
 

6.3 - GUARANTEE AND REPAIRS 

The instrument is under warranty against manufacturing flaws 
or faulty material, that are found within 12 months from delivery 
date. 
The guarantee is limited to repairs or to the replacement of the 
instrument. 
The eventual opening of the housing, the violation of the 
instrument  or the improper use and installation of the product 
will bring about  the immediate withdrawal of the warranty’s 
effects. 
In the event of a faulty instrument, either within the period of 
warranty, or further to its expiry, please contact our sales 
department to obtain authorisation for sending the instrument 
to our company. 
The faulty product must be shipped to OSAKA with a detailed 
description of the faults found, without any fees or charge for 
OSAKA, except in the event of alternative agreements. 

7 - TECHNICAL DATA 

 

7 – TECHNICAL DATA

 

 

7.1 - ELECTRICAL DATA 

Power supply: 24, 115, 230 VAC +/- 10% 
Frequency AC: 50/60 Hz 
Power consumption: 9 VA approx. 
Input/s: up to 4 inputs for temperature probes tc J,K or RTD Pt 
100 IEC (2 wires). 3 digital inputs for free voltage contacts 
Output/s: Up to 7 outputs. STEAM output SPST-NO (16 A-
AC1, 6 A-AC3 / 250 VAC), the others outputs SPST-NO (8 A-
AC1, 3 A-AC3 / 250 VAC). 
Electrical life for relay outputs: 100000 operat. 
Installation category: II 
Measurement category: I 
Protection class against electric shock: Class II for Front panel 
Insulation: Reinforced insulation between  the low voltage 
section (supply, relay outputs) and the front panel; Reinforced 
insulation  between the low voltage section (supply, relay 
outputs) and the  extra low voltage section (inputs); 50 V 
insulation between RS485 and extra low voltage section. 
 

7.2 – MECHANICAL DATA 

Housing: Self-extinguishing plastic 
Dimensions: 72 x 144 mm DIN, depth 77 mm 
Weight: 600 g approx. 
Mounting: Flush in panel in 68 x 139 mm hole 
Connections: extractable 2,5 mm 

screw terminals block 

Pollution situation: 2 
Operating temperature: 0 ... 50 °C 
Operating humidity: 30 ... 95 RH% without condensation 
Storage temperature: -10 ... +60 °C 
 
 

7.3 – MECHANICAL DIMENSIONS, PANEL CUT-OUT AND 
MOUNTING [mm] 

 

 

 

 
7.4 - FUNCTIONAL FEATURES 

Control: ON/OFF 
Measurement range: according to the used probe (see range 
table) 
Display resolution: 1° 
Overall accuracy: +/- 0,5 % fs 
Sampling rate: 300 ms. 
Serial Interface : RS485 insulated 
Communication protocol: MODBUS RTU (JBUS) 
Baud rate: Programmable from 2400 ... 38400 baud 

Содержание COC 30

Страница 1: ...UNCTIONAL DATA 7 5 MEASUREMENT RANGE TABLE 7 6 INSTRUMENT ORDERING CODE DE 1 INSTRUMENT DESCRIPTION 1 1 GENERAL DESCRIPTION Model COC 30 is a microprocessor based digital controller designed to command ovens particularly those used in bakeries The instrument s main feature is the possibility to have separate control over the temperature and heating powers for the TOP and FLOOR of the oven as well ...

Страница 2: ...functions The panel therefore shows all the displays and all the leds to be active with the exception of the Stand by Led off OFF STAND BY meaning that the control device does not activate any control function with the exception of the light command The display is therefore off with the exception of the Stand by led which is lit If the automatic switch on timer is present in the OFF status it is p...

Страница 3: ...ng of the CLOCK led and the flashing of the hh mm separation led At the programmed time the control device will switch on automatically To deactivate the switching on timer press the START key for 1 second or switch the instrument on ahead of time If you wish the oven to switch on and switch off automatically in this mode the cooking time must also be programmed once the cEF parameter has been pro...

Страница 4: ...s possible to the instrument and located in a position that can easily be reached by the user and marked as instrument disconnecting device which interrupts the power supply to the equipment It is also recommended that all the electrical circuits connected to the instrument must be protect properly using devices ex fuses proportionate to the circulating currents It is strongly recommended that cab...

Страница 5: ...taneously on therefore if the two resistances are equal the maximum power absorbed is 50 This occurs in any case when without the limiter being on the sum of the two powers is less than 100 Therefore the function with the power limiter on starting from the count of the cycle time is as follows 1 the TOP output remains on for the time tCP 2 x OP1 100 2 Both outputs remain off for the time tCP 2 tCP...

Страница 6: ...ill activate when the temperature value rises above the AnH alarm threshold and will deactivate when it drops below the AnH HAn value 4 4 OVEN LIGHT CONTROL The LIGHT key can be used to activate deactivate the LIGHT output the activation of the output is therefore indicated by the LIGHT led When the controller is switched off the output is in any case switched off but in standby mode the output ca...

Страница 7: ...eam injected being extracted On In this case the output if on switches off when steam injection starts and remains switched off for the entire duration of injection and even after it finishes for a certain time in sec that can be set under the Edt parameter Moreover using the EAS On parameter it is possible for the extractor output to be activated if it is not already automatically when cooking is...

Страница 8: ...ands the extractor connecting the EXTR relay outputs of all the others in parallel and therefore at the digital input of the former which will have suitably programmed the digital input with this operation mode 4 9 RS 485 SERIAL INTERFACE The instrument can be equipped with a RS 485 serial communication interface by means of which it is possible to connect the regulator with a net to which other i...

Страница 9: ...larm 1 0 999 seg 0 38 A2t com Alarm type AL2 Ab dE Ab 39 A2L com Lower threshold alarm 2 99 999 99 40 A2H com Upper threshold alarm 2 99 999 999 41 HA2 com Hysteresis alarm 2 1 999 1 42 A2d com Delay activation of alarm 2 0 999 sec 0 43 Pod com Disabling alarms on switching on 0 999 min 0 St Group steam control parameters Par Description Range Def 44 SPS Steamer regulator Set Point 99 999 130 45 H...

Страница 10: ... External alarm signal on input intervention the alarm is activated and the upper display alternately shows AL1 and the temperature measured 2 Auxiliary output AUX remote control the digital input is used for the command of the auxiliary output AUX as described in the AOF 4 operating mode of the auxiliary output 3 steam injection remote control the digital input operates as the instrument s INJ ke...

Страница 11: ...R output function in relation to the relative key as bistable OFF or monostable ON In practice bistable operation means that the first time the EXTR Key is pressed the output activates and remains activated whereas the second time deactivates it Monostable operation means that the output is activated only when the key is pressed AO Group AUXILIARY OUTPUT PARAMETERS for setting the AUX output AOF A...

Страница 12: ...with a detailed description of the faults found without any fees or charge for OSAKA except in the event of alternative agreements 7 TECHNICAL DATA 7 TECHNICAL DATA 7 1 ELECTRICAL DATA Power supply 24 115 230 VAC 10 Frequency AC 50 60 Hz Power consumption 9 VA approx Input s up to 4 inputs for temperature probes tc J K or RTD Pt 100 IEC 2 wires 3 digital inputs for free voltage contacts Output s U...

Страница 13: ...UT RANGE tc J Model C SEn J 50 999 C 58 999 F tc K Model C SEn CrA 50 999 C 58 999 F Pt100 IEC Model D 50 600 C 58 999 F 7 6 INSTRUMENT ORDERING CODE COC 30 a b c d e f g hh a INPUTS TYPE C thermocouples J K D thermoresistances Pt100 b SUPPLY D 230 VAC C 115 VAC A 24 VAC c AUXILIARY PROBE INPUT none A YES d AUXILIARY OUTPUT none R YES e STEAMER PROBE INPUT none V YES f COMMUNICATION INTERFACE No i...

Отзывы: