background image

1. Purpose

The wireless relay Relay-R (hereinafter referred to as the “relay”) is designed for switching the

load in a single-phase 100-240VAC. The relay is controlled by commands from the "Lun" series Con-
trol Panel (for more details on compatibility, see the Control Panel operating manual) through the

"Lun-R" receiver.

Product is not equipped with built-in cameras and microphones, devices and units for

hidden video and audio recording.

2. Safety Precautions

Only the employees, familiar with the module design, instructed on the safety arrangements

shall be allowed to install, routinely maintain and repair.

The device has an open live parts, representing the danger of electric shock to a person

– it is a terminal block marked as IN. No safety ground. You must turn off the power BE-
FORE connecting and disconnecting the product.

3. Technical specifications 

The relay technical characteristics is shown in the Table 1.

Table 1. Technical characteristics

Characteristic

Value

Operating frequency range (depends of modification), MHz

433.05…434.79 or

868.70…869.20

Power radiated by the transmitter, mW

up to 10

The health test signals period, seconds

60

Maximum switching current for resistive load, A

7

Mains supply voltage (50Hz), V

85…305

Power consumption from the mains supply, VA

1.5

Degree of protection provided by enclosure

IP20

Dimensions, mm

66*66*35

Weight, g

200

Relay-R

Version en_2

3

Содержание Relay-R

Страница 1: ...iance with operating modes and conditions therefore this document require ments is mandatory Wireless Relay Relay R Operation manual ORTUS Group Product Compatibility Table Compatible radio receiver Lun R Version Configuration Software Configurator 11 Version Central Monitoring Station Orlan Version Relay R Version en_2 1 ...

Страница 2: ...ical specifications 3 4 How to use 4 4 1 Modes Indication 4 4 2 Binding 5 4 3 Schematic diagram 5 4 4 Wireless signal strength 6 4 5 Installing 6 5 Maintenance 6 6 Operating conditions 6 7 Storage 7 8 Transportation 7 9 Disposal 7 Relay R Version en_2 2 ...

Страница 3: ...n and repair The device has an open live parts representing the danger of electric shock to a person it is a terminal block marked as IN No safety ground You must turn off the power BE FORE connecting and disconnecting the product 3 Technical specifications The relay technical characteristics is shown in the Table 1 Table 1 Technical characteristics Characteristic Value Operating frequency range d...

Страница 4: ...gered and the tamper norm event will be generated In addition the relay transmits periodic test signals to the receiver to confirm its operability When the test signals stop the control panel generates the relay communication lost event The relay switching is carried out in accordance with the commands transmitted from the control panel of the Lun series see the Control Panel operating manual The ...

Страница 5: ...ode see the corresponding control panel programming manual 4 Connect power cable from mains to the relay use the IN terminal block 5 Switch the relay to the binding mode by short circuit the RESET contacts for 2 3 sec onds until the blinking green the signal Binding 6 Binding will processed automatically and if successful ends by turning on the red LED for 2 3 seconds signal Bound The relay waits ...

Страница 6: ...on so that its antenna is located vertically Do not place relay on or near metal surfaces closer than 1m or inside metal structures 2 Open the cover of the relay housing by unscrewing its fastening 3 Fasten the relay to the selected installation location using self tapping screws 2 pcs through the holes in the relay housing 4 Insert the antenna in the terminal block with the marking passing its no...

Страница 7: ... package 8 Transportation 1 Relay transportation shall be carried out in the manufacturer s package 2 Relay is allowed to be transported by all types of enclosed transporters subject to observing the shipping rules applicable for each type of transport 3 Transportation temperature shall be of 50 C to 50 C at the relative humidity of 5 up to 98 9 Disposal Relay disposal shall be carried out accordi...

Страница 8: ...Manufacturer ORTUS Group 1 East Liberty 6th Floor Reno NV 89501 USA Tel 1 650 240 27 62 mail info ortus io http www ortus io Relay R Version en_2 8 ...

Отзывы: