Control elements and their function in manual operation
The control lever is labelled with its function.
Caution! The air supply may only be closed completely after the complete combustion of the wood (danger of
deflagration).
The dual-pane glass door is opened or closed with the use of the door closure lever.
When closing the door, pay attention to the engagement of the lock. Only a correctly locked combustion chamber
door ensures a secure combustion. The combustion chamber can now be loaded with wood and the wood can be
ignited. In order to prevent the release of heating gas, the firebox door must always be closed except during lighting,
when refilling with fuel, and during ash removal. In order to refill fuel, the door may only be opened after the wood
has been burnt (shortly before the embers phase).
Control elements and their function in automatic operation
The dual-pane glass door is opened or closed with the use of the door closure lever. Pressing the door handle upwards
will release the door and it can then be opened. When the door handle is pressed down, the door is locked and with
this, the ST11 is operational.
When pressing the door lever down, pay attention to the engagement of the lock. Only a correctly locked combustion
chamber door ensures a secure combustion.
Manual control lever
Door contact switch
Inlet
air
damper