Building Around the Fireplace 

 

Building Checklist 

The following building checklist is a quick reference for a typical 77HH series fireplace installation. This list is 

not exhaustive and does not supplement thorough review of the installation manual. 

 

Fireplace Location:

 Ensure the location allows for min. 40” clearance from viewing area to furniture 

and other combustibles. Make sure a clear path is established to allow the fireplace to be safely 

transported to installation location. 

 

Exhaust Vent:

 Confirm vent size (5”x8”, or 3”x5” for Power Vent), vent clearance (1” on sides and 

bottom, 3” on top), vent configuration, and termination location. 

 

Height from Floor:

  Fireplace leg height is 9 

13

/

16

” (to bottom viewing area). Legs cannot be 

removed/altered. If desired viewing area location on the wall is higher than 9 

13

/

16

”, a platform can be 

built for the fireplace to stand on. 

 

Chase Floor/Platform: 

Fireplace can stand on the chase floor or a platform. Floor or platform must be 

able to bear the weight of the fireplace. It can be constructed out of wood, concrete, metal, or any other 

solid materials (not required to be non-combustible). 

 

Chase Construction:

 No materials can be attached directly to the fireplace (exception: 

5

/

8

” Type X 

Drywall). The area of the chase interior must be min. 200 square inches at any given point within the 

chase. 

 

Framing:

 Adhere to minimum framing dimensions (or greater). The first 10

 

7

/

16

” above the top of the 

fireplace viewing area must always be non-combustible framing. For recessed fireplaces, do not exceed 

12” max. front overhang depth limit. For Corner and TS models, side overhang has no limit. No material 

is permitted to extend past the metal lip surrounding the fireplace viewing area.

 

 

5

/

8

” Type X Drywall Requirements:

 One layer of 

5

/

8

” Type X Drywall (or equivalent) must be installed 

on the exterior of the chase framing. 

5

/

8

” Type X Drywall (or equivalent) may be fastened to the top 

framing stand-off(s) only, with 1" self-tapping drywall screws 16'' on center. 

 

TV/Artwork:

 TV/Art must be min. 4” above top of fireplace viewing area for flush-mounted TVs, and 12” 

for TVs recessed into the wall. First 10

 

7

/

16

” min. above the viewing area must have non-combustible 

framing (top front metal stand-off + non-combustible studs). 

 

Gas Supply Line and Power Location:

 Locate gas line with manual shut off according to local code. 

Power provided by a duplex outlet receptacle (120V, 15 amp, 60Hz) in same area as gas line.  

 

Access Panel:

 An access panel is highly recommended to access gas and electrical components for 

servicing. Depending on the model, access panel can be placed at side or back of the fireplace within 

3 feet of the pilot. Access panel, or some other form of clear access to the chase, is required for power-

vented fireplaces. Size recommendation: as large as possible depending on application. Min. 

recommended size 10”x10”. 

 

Heat Release: 

Crucial for Cool Wall Technology.

 Must start within 6” (max.) from the chase’s ceiling. 

Min. horizontal heat release size is 200 sq.in. of net free air space (vertical heat release requires 260 

sq.in.). Height of the heat release must not exceed 1/3 of the width. 

 

Air Intake:

 Must be located at or below level of double glass fans. Min. 200 sq.in. of net free air space.

 

 

Finishes: 

For finishes flush to the fireplace, no clearances are required. For finishes where the fireplace 

is recessed to the finish, maintain 

1

/

8

" from the finish to the front face of the fireplace.  

 

Содержание 77HH Corner LS

Страница 1: ...Ortal Installation Manual 77HH Series V1 0 Installation and Operation Manual Ortal 77HH Series Ortal 77HH Series Fireplaces 77HH Front Facing 77HH Corner RS LS 77HH Three Sided TS...

Страница 2: ...fireplace and shall be installed The fireplace MUST not be used without the heat barrier in place If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this...

Страница 3: ...General Clearances 15 Heat Release 16 Air Intake Opening 18 Mounting a TV Artwork 20 Access Panel 22 Chase Area Minimum 22 Recessed Ledge Detail 23 Structural Weight Support 24 Step by Step Chase Cons...

Страница 4: ...44 Operating Instructions 44 Puck Handset 45 Operating Instructions 46 Wall Switch 47 Operating Instructions 47 MyFire App 48 Operating Instructions 48 MyFire Wi Fi Box 48 Fireplace Maintenance 49 Ge...

Страница 5: ...as an Accredited Standards Developer Certification Standard US ANSI Z21 88 2019 Vented Gas Fireplace Heaters Canada CSA 2 33 2019 Vented Gas Fireplace Heaters Products CLASS 2901 84 DOMESTIC HEATERS...

Страница 6: ...an area easily accessible by the owner typically near the access panel if available You must instruct the owner before handing over the fireplace where this label can be found OWNERS Make sure the in...

Страница 7: ...irflow inside the chase These stand offs can directly touch combustible framing Top Framing Stand offs Attached to the front top portion of the fireplace above the glass viewing area It keeps a cleara...

Страница 8: ...ult with the contractor and go over all requirements Chase framing requirements 5 8 Type X Drywall or equivalent requirements Heat release requirements Air Intake requirements Access panel size and lo...

Страница 9: ...d safety barrier Review operation of the fireplace and remote control with the owner Set up return visit to clean glass after the Initial Burning Period see Post Installation section below Post Instal...

Страница 10: ...has no limit No material is permitted to extend past the metal lip surrounding the fireplace viewing area 5 8 Type X Drywall Requirements One layer of 5 8 Type X Drywall or equivalent must be install...

Страница 11: ...8 Type X Drywall or equivalent Chase interior does not require a layer of 5 8 Type X Drywall This applies to both combustible and non combustible framing NOTE 5 8 DensGlass Fireguard Sheathing is an a...

Страница 12: ...the only permitted application The fireplace may be recessed into the wall Refer to diagrams and values below and in the following pages for details 77HH Front F Series Fireplace A Height B Length C D...

Страница 13: ...Depth D Stand Off E Legs F Glass Length G Glass Height 77HH RS LS 49 1 2 84 13 16 21 5 8 10 7 16 9 13 16 78 5 8 29 1 2 Framing Fireplace 77HH RS LS A Height 49 1 2 B Length 84 13 16 C Depth 21 5 8 V...

Страница 14: ...th C Depth D Stand Off E Legs F Glass Length G Glass Height 77HH TS 49 1 2 82 13 16 21 5 8 10 7 16 9 13 16 81 1 2 29 1 2 Framing Fireplace 77HH TS A Height 49 1 2 B Length 82 13 16 C Depth 21 5 8 V Fi...

Страница 15: ...g area at a 90 angle Building Material The temperature on the side wall can get as high as 150 F above ambient temperature While the fireplace certification allows for this temperature variance buildi...

Страница 16: ...es only the height of the heat release must not exceed 1 3 of the width This does not apply to vertical heat releases The space the heat release vents into must have a minimum volume of 184 ft3 The he...

Страница 17: ...elease is oriented vertically Entire heat release is on one side of the fireplace chase Split Front Vertical Heat Release Full Vertical Heat Release on One Side Sprinkler Clearance to Heat Release In...

Страница 18: ...finished in the form of a louvered ventilation grille gap or toe kick reveal For louvered ventilation grilles the net free air space allowed in the louvered area must be equal or greater than the min...

Страница 19: ...19 Air Intake for a Platform NOTE Please refer to the Chase Floor Platform section on page 11 for details on platform construction...

Страница 20: ...information Wires inside the chase are not permitted to cross over the fireplace Wires must be installed against a wall The decision to install a television above an Ortal fireplace is up to the disc...

Страница 21: ...area At 12 inches above the fireplace viewing area maximum possible recess is 5 inches A deeper recess will interfere with required clearances to venting Maximum possible recess increases at 12 inches...

Страница 22: ...design media and lifting the grill burner and bottom pressure release valve This will increase service time and difficulty An access panel is always preferred Fireplace dealers installers are advised...

Страница 23: ...ucture must be non combustible framing and finish Ledge Size A x B 520 sq in A ledge depth B ledge width Top View Oversized Ledge If ledge surface area exceeds 520 sq in the heat release must be divid...

Страница 24: ...face Consult with the project structural engineer and refer to your local building codes for proper wall support The following drawing shows a recommended approach to this type of installation Please...

Страница 25: ...e designated access panel location If the fireplace will not have an access panel keep gas valve and receiver unit directly underneath the fireplace Run gas and electric to the gas valve and receiver...

Страница 26: ...fireplace viewing area This area must be unobstructed to allow the heat barrier and inside glass panel to be removable MANUFACTURED STONE A minimum 2 inch recess is suggested Consult stone manufacture...

Страница 27: ...epth is measured from the edge of the fireplace lip to the out most part of the wall including finish material Side overhang has no limit Finish material on the underside of the overhang may be combus...

Страница 28: ...Vent System Selkirk Direct Temp System Enervex RS Power Vent optional Ortal Power Vent optional 3x5 co axial direct vent pipe 3 interior 5 exterior DuraVent CVS line Power Vent a fan assisted direct...

Страница 29: ...a 90 elbow that stays in the horizontal plane 6 feet must be reduced from the total allowable horizontal run Up to two flat elbows are allowed Example If max allowable horizontal run is 24 feet and 1...

Страница 30: ...place Allowable Maximum Horizontal Runs 77HH Series 160 Single Burner V minimum 6 feet Vertical V Max Horizontal H 6 ft 18 ft 9 ft 19 ft 12 ft 19 ft 15 ft 19 ft 18 ft 19 ft 21 ft 19 ft 24 ft 19 ft 27...

Страница 31: ...l 77HH Series V Minimum 6 Feet Total Vertical Vent Rise 44 2 75 X X X X X X X X X X X 42 2 75 1 97 1 97 X X X X X X X X X 39 2 75 1 97 1 97 1 97 X X X X X X X X 36 2 75 1 97 1 97 1 97 X X X X X X X X...

Страница 32: ...and sof ts 1 There must be 3 feet minimum between termination caps 2 All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap 3 All gravity...

Страница 33: ...Alcove height Q US Canada See table below Alcove width dependent on number of caps in the space R US Canada See table below Alcove depth dependent on number of caps in the space Vent Caps QMINIMUM RM...

Страница 34: ...does not apply to a chimney shroud application See the Chimney Shroud section on the next page for more information TERMINATION CAP NOTE A Low Profile Termination Cap can negatively impact flame appe...

Страница 35: ...d to the fireplace starter collar with a minimum of 3 sheet metal screws no longer than DO NOT use silicone to seal the sections If sealing is required by the vent manufacturer or local code use Mil P...

Страница 36: ...components are attached to the pilot on a flexible gas line and can be kept directly under the fireplace or depending on the model moved to the left right or back of the fireplace within 36 inches of...

Страница 37: ...s following the figure Part Number Description Part Number Description ASB001 Pilot Bracket ASB002 Pilot Gasket D23 Orifice LPG G13 Electrode Target Type D36 Orifice NG G121 Main Burner Gas Fitting G0...

Страница 38: ...cy 1 Press and hold the receiver s reset button until you hear two beeps The first beep is short and the second beep is long After the second beep release the reset button 2 Within the subsequent 20 s...

Страница 39: ...quired for different feature combinations For wiring diagrams with Ortal or Enervex power vent refer to the applicable power vent manual For wiring diagrams with CO shutoff kit refer to CO Shutoff Kit...

Страница 40: ...40 Wiring Diagram Double Glass Fireplace with Interior Lighting...

Страница 41: ...ems only and will not connect the fireplace to a wireless system Interior Design Media Ortal offers interior media options such as stones glass logs and embers that can be provided with the fireplace...

Страница 42: ...l injury Do not use the hood to support media This could cause overheating of the thermocouple Keep the media away from the edges and the glass Do not overfill the media tray Keep 20 of the tray open...

Страница 43: ...me from creating soot on the media or to manipulate the look of the flame Block as few ports as possible and no more than 30 of total ports Do NOT block ports that are next to one another When combini...

Страница 44: ...therefore will not operate during a power failure Only the Mertik Maxitrol AC Adapter is permitted for use with the fireplace Use of other adapter brands can render the system inoperable The handsets...

Страница 45: ...o turn the fireplace off NOTE The fireplace may be turned on again after the OFF icon stops flashing Flame Height Adjustment 1 To increase flame height press and hold the button to desired flame heigh...

Страница 46: ...rease Flame Height INCREASE To increase flame height press and hold button DECREASE To decrease flame height press and hold button Holding the button long enough sets the fireplace to pilot flame Stan...

Страница 47: ...ight Adjustment INCREASE To increase flame height press and hold up flame button DECREASE To decrease flame height press and hold down flame button Holding the down flame button long enough sets the f...

Страница 48: ...up and operating instructions of the MyFire app see the Homeowner s Fireplace Operation Manual or visit the Ortal website or www myfireapp com MyFire Wi Fi Box The MyFire Wi Fi router box provides the...

Страница 49: ...out the glass properly securely in place Only an Ortal certified installer is authorized to remove the glass Glass must be removed using an 8 inch glass handling suction cup Lower the glass to rest in...

Страница 50: ...Ortal 2022 Version 1 0 August 2022 SKU KPMAN77HHNLUSV1 0 Ortal USA 2152 Citygate Drive Columbus OH 43219 T 818 238 7000 F 818 678 0541 info ortalheat com www ortalheat com...

Отзывы: