![Orolia Seven Solutions WR-ZEN Series Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/orolia/seven-solutions-wr-zen-series/seven-solutions-wr-zen-series_user-manual_1654218081.webp)
OID
Name
Value Type
Description
19.xx12.4
Servo State
<Enum>
0. Disabled
1. ---
2. Waiting Sync Sec
(+)
3. Waiting Sync Sec
(-)
4. Error
5. Frequency estim-
ation
6. Tracking
7. Not updated
8. Locked
State of the PTP servo. For a port set as slave, the
servo should reach the “Locked” state to prop-
erly perform the synchronization. NOTE: The
state “---” has been created for PTP master ports
because for this mode the servo state is irrel-
evant.
19.xx12.12
Mode of
Operation
<Enum>
0. Two Step
1. One Step
2. Disabled
Reports the current mode of operation received
from the master. Two steps=Sync+FollowUp,
One step=Sync
19.xx12.26
Rx Sync Pack-
ets
<Integer>
Number of received sync messages (Incre-
menting for Slave instances)
19.xx12.31
Tx Sync Pack-
ets
<Integer>
Number of transmitted sync messages (Incre-
menting for Master instances)
19.xx12.28
Rx DelayReq
Packets
<Integer>
Number of received delay request message
(Incrementing for Master instances)
19.xx12.33
Tx DelayReq
Packets
<Integer>
Number of received delay request message
(Incrementing for Slave instances)
Then if a specific interface is not disabled (Port State ≠ None), by clicling on the (+) a user
will expand the interface to its Advanced View to get more information about the PTP
exchange. The bi-directional exchanges of PTP is resumed in
exchange for delay measurement (1) End-to-end (2) Peer-to-peer." on page 67
, where
the number of packets for each type of messages is provided by the parameters in
advanced view (see the table below).
Table 5-4:
Advanced PTP information for a port instance
19.xx12.x
net/<iface>/1/info
Information on the corresponding
<iface> port instance
.
19.xx12.2
Calculated
Offset
<Decimal> (f64)
The value represents the actual offset (in
seconds) between master and slave. It is cal-
culated from the retrieved timestamps with cor-
rections from calibrations & asymmetries
settings.
19.xx12.3
One-Way
Delay
<Decimal> (f64)
One-way path delay in seconds (equivalent to
delay_MS)
5.4 IEEE 1588-2008 (PTPv2)
CHAPTER
5
•
WR-Z16 User Manual Rev. v3.4
71
Содержание Seven Solutions WR-ZEN Series
Страница 1: ...WR Z16 MODEL User Manual Revision v3 4 Date 14 October 2022 ...
Страница 2: ......
Страница 4: ...Blank page II WR Z16 User Manual ...
Страница 16: ...BLANK PAGE 1 4 About White Rabbit High Accuracy Technology 6 CHAPTER 1 WR Z16 User Manual Rev v3 4 ...
Страница 38: ...BLANK PAGE 3 2 Connecting to the Device 28 CHAPTER 3 WR Z16 User Manual Rev v3 4 ...
Страница 104: ...BLANK PAGE 6 5 Firewall 94 CHAPTER 6 WR Z16 User Manual Rev v3 4 ...
Страница 144: ...BLANK PAGE 8 5 Failsafe Mode 134 CHAPTER 8 WR Z16 User Manual Rev v3 4 ...
Страница 167: ...V Virtual Clock 47 W Web GUI 32 White Rabbit 2 58 WR 2 WRZ OS 3 WR Z16 User Manual iii INDEX ...