background image

 

   9 

Adding user ID cards and access codes  

(The PIN number can be any 4-6 digit number in the 
range 0000-999999 except for the code "1234"). 

Add a card in the same way as in card mode or code mode (302#). 

Press 

*

 to enter programming mode.  

Then assign a PIN code to the card according to the scheme:  

*  Read card 1234 # PIN code # PIN code #

 

Changing the PIN access code (can be done out of programming mode, without the involvement of the system administrator) 

Method 1  
Note: this operation must be performed out of the 
programming mode so that the user can do it 
themselves. 

 *  Read card  Old PIN code #   New PIN code #   New PIN code # 

 

Method 2 
Note: this operation must be performed out of the 
programming mode so that the user can do it 
themselves. 

 *  ID Number #  Old PIN code #   New PIN code #  New PIN code # 

 

Deleting PIN code and ID card (simply delete only the 
card from the system) 

2  ID Number   #

 

Adding and deleting users in card-only mode (proximity tag) 300#

 

Adding or deleting users 

Proceed in the same way as in the card or code mode (302#)

 

Deleting 

all users

 

Delete 

all users

. Note: this function is irreversible. Please 

think twice before performing it. 

2   0000   #

 

Door opening 

It is possible to program the code lock to operate in one of two relay activation modes: monostable and bistable. 

Monostable mode 

4   time from 01 to 99 seconds # 

This is the mode set by default. When a valid card (proximity tag) is placed close to the reader or a 
valid access code is entered, the output relay's latch is released for a pre-programmed time period 
and then locked again until a valid card (proximity tag) is brought close again or a valid access code 
is entered. The factory setting is 6 seconds. You can enter a value between 1 and 99 seconds.

 

Bistable mode 

4   0   # 

In this mode, when a valid proximity card (proximity tag) is brought close to the reader or a valid 
access code is entered, the exit relay bolt is released and remains in this state until a valid ID card 
is  brought  close  again  or  a  valid  access  code  is  entered  (the  card/code  alternately  releases  and 
locks to the premises).

 

Alarm setting

 

Alarm duration adjustment (1-3minutes) 
Factory setting is 3 minutes. 

 5   0

3   #

 

Door opening detector setting

 

To use the function, connect the open door detector 
(contracton) to the magnetic lock and then select one of 
the sequences in the programming mode: 

 6   0

 

0   #

  

deactivation of the function (factory setting) 

6   0

 

1   #

  

deactivation of the function 

There are 2 programming functions that operate in this mode.  
a. If the door is not closed when opened, the keypad buzzer will operate.  
b. If the door has been forcibly opened, the keypad buzzer will operate and the alarm 
will sound

 

Security function setting

 

There are two options for securing the device's keypad: 

 7   0  1   # reading of 10 invalid cards or entering consecutively 4 wrong access codes 
(PIN) locks the keypad for 10 minutes 

7   0  2   # reading of 10 invalid cards or entering consecutively 4 wrong passwords 
triggers the keypad buzzer and activates the alarm signal

 

Deactivation of function 

 7   0  0   # Factory setting, does not delete users

 

Reset the device to factory settings

 

To reset the device, press and hold the * button on the keypad and connect to the power supply. You will hear three beeps (two short and one 
long) which will indicate that the device has been reset correctly. A long beep will sound when the button is released. 

Resetting the device does not delete the users but deletes the MASTER CODE. 

   
 
 
 

 

Содержание OR-ZS-802

Страница 1: ...in Wasser oder andere Fl ssigkeiten 3 Verwenden Sie die Einrichtung nur ordnungsgem 4 Nutzen Sie das Ger t nicht wenn sein Geh use besch digt ist 5 ffnen Sie die Einrichtung nicht und f hren Sie kein...

Страница 2: ...yw przedni do cianki tylnej Rys 1 Rys 2 INSTALACJA 1 Oddzieli podstaw mocuj c zamka od pokrywy g wnej w tym celu nale y odkr ci rub mocuj c z do u zamka 2 Wywierci otwory i umie ci w nich 4 ko ki mont...

Страница 3: ...na zaprogramowa w pami ci zamka Istnieje mo liwo zaprogramowania 3 r nych metod aktywacji zamka a wej cie na posesj tylko przy pomocy autoryzowanej karty zbli eniowej ID b wej cie na posesj przy pomo...

Страница 4: ...ika ID musi by 3 cyfrow liczb z przedzia u 000 999 Nie myli z kodem dost pu u ytkownika Numery identyfikacyjne u ytkownik w musz by r ne dla ka dego breloka Numer PIN mo e by dowoln liczb 4 6 cyfrow z...

Страница 5: ...arty breloka zbli eniowego lub po wprowadzeniu wa nego kodu dost pu rygiel na wyj ciu przeka nika zostaje zwolniony i pozostaje w tym stanie a do momentu ponownego zbli enia wa nej karty ID lub wprowa...

Страница 6: ...reading distance 2 6 cm PIN code length 4 6 digits Current consumption at rest 20mA Lock output load max 3A Alarm output load max 3A Operating temperature 40 60 Protection level IP44 Adjustable door...

Страница 7: ...7 Do not connect the transformer to the mains until the internal installation work has been completed and the front cover of the unit has been fitted WIRING DIAGRAM...

Страница 8: ...ess Note only one can be selected Access only with card proximity tag 3 0 0 Access by card proximity tag and PIN code 3 0 1 Access by card proximity tag or PIN code 3 0 2 factory mode default Activati...

Страница 9: ...ode is entered The factory setting is 6 seconds You can enter a value between 1 and 99 seconds Bistable mode 4 0 In this mode when a valid proximity card proximity tag is brought close to the reader o...

Страница 10: ...r Ablesung der ID Karte 2 6 cm L nge des PIN Codes 4 6 Ziffern Stromverbrauch im Bereitschaftszustand 20mA T rrelais max 3A Belastung des Notausgangs max 3A Betriebstemperatur 40 60 Schutzart IP44 Zei...

Страница 11: ...arer Eingang 5 12 V Rot 12 VDC positiver Spannungseingang 6 D_IN Braun Zum T rkontakt dann zum negativen Pol 7 OFFEN OPEN gelb Der Knopf zum Verlangen die T r aufzumachen dann zum negativen Pol 8 ALAR...

Страница 12: ...Taste gedr ckt geht das Ger t aus dem Programmierungs Modus aus Verlassen des Programmiermodus Hinweis der Hauptbenutzer muss angemeldet sein um die Programmierung durchzuf hren Nach jedem Schritt de...

Страница 13: ...odus verlassen zu m ssen L schung einer Karte des Benutzers mithilfe einer Benutzernummer 2 ID Nr des Benutzers Hinzuf gung und L schung von Benutzern im Modus Karte N herungsschlusselanh nger und PIN...

Страница 14: ...ktion ausgeschaltet voreingestellt 6 0 1 Funktion eingeschaltet Es gibt 2 Programmierungsfunktionen die in diesem Modus funktionieren a Wird die T r nach der ffnung nicht zugemacht wird ein Tastatursu...

Отзывы: