6
EN
Operation Instruction
DESCRIPTION AND USE
OR-ZS-802 code lock is a single-relay standalone device with an access control keypad. It uses the latest microprocessor technology to handle the locking of doors and
security systems that require immediate closing (in terms of time) or closing the locking contact. Programming is carried out via the numeric keypad. Codes and
parameters are stored in the microprocessor and are not lost during a power failure.
ELEMENTS OF THE SET
Numeric keypad x 1
Proximity tag EM 125kHz x 1
Operating instructions x 1
Set of fixing screws x 1
TECHNICAL SPECIFICATION
Operating voltage:
12V DC
User capacity:
1000
Reader frequency:
125 kHz
Keypad:
12 keys; 3 x 4 digits
Card type:
ID
Card reading distance:
2-6 cm
PIN code length:
4-6 digits
Current consumption at rest:
<
20mA
Lock output load:
max. 3A
Alarm output load:
max. 3A
Operating temperature:
-40
℃
~
60
℃
Protection level:
IP44
Adjustable door relay time:
0-99 seconds
Adjustable alarm time:
1-3 minutes
Memory:
EPROM, non-volatile
Access codes:
1 x Master Code
1000 cards (proximity tags)
1000 PIN codes
Net weight:
0.5kg
INSTALLATION
1.
Fix the back plate on the wall with three screws at least
2.
When you have finished connecting, fasten the front cover to the back panel
Fig.1 Fig.2
INSTALLATION
1. Separate the lock fixing base from the main housing (to do this, unscrew the fixing screw at the bottom of the lock)
2. Drill holes and insert 4 mounting dowels.
3. Connect the wires from power supply and electromagnetic lock to the sockets as shown in the wiring diagram (Fig. 3)
4. Fix the code lock base to the wall
5. Attach the front cover (Fig. 2).
Connector 1 functions