Page
10
E) Installation of the transformer
Attach the transformer to a DIN rail in a modular fusebox or to a flat surface using
the two black lugs clipped to the sides of the power supply.
Performance Settings
You can adjust the brightness,contrast and colour of the monitor when it is ON by
pressing the Menu button at the side of the monitor.
Press the Menu button then the brightness,contract and colour indication will appear.
To select the indication by pressing the Up and Down buttons,then press the Menu
button to confirm the selection and then press the Up and Down buttons to adjust.
Finally,press the Menu button to confirm the setting.
Operating Instructions
Important:The touch keys must be handled by slightly touching with the fingers.
1. Activation of units
When the call button on the outside camera unit is pressed, the indoor unit chime
rings and the visitor’s picture will appear on the indoor monitor. After the visitor is
visually identified,and if you wish to talk with the visitor,touch the
button.The
unit will remain activated for approximately
60 seconds before it automatically
shuts off.
To re-activate for continued conversation,touch the
button and then touch the
button.
2. Activation of outside unit from monitor unit
a) Touch the
button of the indoor unit at any time and the outdoor camera
will be activated and show the outside view.
b) If you has installed two cameras,touch this button to change from camera
one to another.
If you press twice the button
that the camera is not connected,you have a
black screen and a noisy sound.After 1 second,the video of the main camera
reappears.
3. Working time
a) Call time: Approximately 30 seconds
The picture terminates automatically if indoor unit is not answered within
approximately 30 seconds after the call button of the outdoor camera unit is
touched.
b) Talk time: Approximately 60 seconds
When monitor unit is called by the outdoor unit and the monitor is answered,
there is approximately 60 seconds of time available before the unit
automatically shuts off.