Orliman OP1172 Скачать руководство пользователя страница 2

ORLIMAN S. L. U. 

C/ Ausias March, 3 - Pol. Ind. La Pobla-L´Eliana

Apdo. de correos 49 · C.P.: 46185  

La Pobla de Vallbona Valencia - España (Spain)

Tel.: +34 96 272 57 04 - Fax: +34 96 275 87 00 

Tel. Exportación: +34 96 274 23 33

E-mail: [email protected] · Export mail: [email protected]

www.orliman.com

OP1172

Fecha de emisión/Date of issue: 2021-09

Fecha de revisión/Revision date: 2022-02 | v.02

Ref.: OP1172

marca

®

USE AND MAINTENANCE INSTRUCTIONS

ENGLISH

EN

 The manufacturing date is included in the batch number which can be found on the packaging 

label as 

x

, in the following way: the second and third digits represent the year of manufacture and 

the fourth and fifth digits represent the month.

INSTRUCTIONS FOR USE, STORAGE AND WARRANTY 

Dear Customer,

Thank you very much for placing your trust in an Orliman product. Please read the instructions carefully. Keep 

these instructions and the packaging for future reference. If you have any questions or concerns, please contact 

your doctor, orthopaedic specialist or our customer service department.

ORLIMAN S.L.U. guarantees all its products as long as the original configuration has not been manipulated or 

altered except for the intended use as described in these instructions.

If the products are used in combination with other products, replacement parts or systems, make sure they are 

compatible and made by Orliman

®

. It does not guarantee any products with altered characteristics due to im-

proper use, defects or breakage of any kind. The statutory regulations of the country of purchase apply. Please 

first contact the retailer from whom you obtained the product directly in the event of a potential claim under 

the warranty. If any serious incidents related to the product occur, notify Orliman S.L.U. and the corresponding 

competent authority in your country.

Orliman would like to thank you for choosing this product and hopes you a speedy recovery.
REGULATIONS

 

d

This article is defined as a class I medical device. A Risk Analysis (UNE EN ISO 14971) has been carried out, 

minimising the existing risks. Tests have been in accordance with European Regulation UNE-EN ISO 22523 on 

Prostheses and Orthoses. 
INDICATIONS

 

Conditions that cause malfunction in the alignment of the lower limbs as a consequence of neurological 

disorders. The aim of the orthosis is to provide a more functional gait pattern and greater autonomy for 

everyday activities.

 

Gait disorders requiring positioning of the lower limbs in abduction in patients with cerebral palsy.

 

Spina bifida.

 

Disorders during embryonic development.

 

Other rare disorders.

 

Patients with hypotonic musculature.

FITTING INSTRUCTIONS

For best therapeutic results considering different pathologies and to extend the useful life of the product, it is 

essential to choose the correct size for each patient or user. Excessive compression may be intolerable; adjusting 

the compression to be firm yet comfortable is recommended.

If the product must be adapted, any such adjustments must be done by an orthopaedic specialist or healthcare 

professional legally certified to do so who must make sure the end user or person responsible for fitting the 

product properly understands how it works and should be used.
When fitting the product, you must adhere to the following instructions:

1-Place the belt around the patient’s pelvic area covering the back and abdomen 

2-Fasten the straps located on the front of the belt to the desired tightness. 

3-Then fit the thigh supports around the top of each thigh, fasten using the strap at the front and attach the 

elastic straps that join the thigh supports to the belt by fastening one end of the strap to the inner thigh and 

wrapping it at least once around the front of each thigh support. 

4-Finally, fasten the other end of the straps in a crossover manner to the back of the belt. 

5-These elastic straps provide a tension gradient and elasticity to control the thigh’s traction and rotation to suit 

the needs of the patient and degree of correction required.

 

p

PRECAUTIONS

Before each use, check that all product components are present as per the fitting process. Periodically check 

the conditions of the product. If you observe any defect or anomaly, immediately report it to the issuing 

establishment.
This product is made of inflammable material. Do not expose the products to situations that could set them 

on fire. In the event of a fire, quickly get them off your body and use the proper resources to extinguish the 

fire.
To avoid minor discomfort caused by sweating, we recommend using some type of cotton fabric to separate 

the skin from contact with the product material. For discomfort such as chafing, irritation and swelling, 

remove the product and see a doctor or orthopaedic specialist. The product should only be used on healthy 

skin. It is not recommended for use over open scars with swelling, redness or hotspots.
Products marked with the 

l

 symbol contain natural rubber latex and can cause allergic reactions in people 

sensitive to latex.
Products marked with the 

o

 symbol contain ferromagnetic components and, therefore, extreme precaution 

must be taken if you undergo an MRI scan or are exposed to radiation associated with diagnostic or thera-

peutic procedures.

RECOMMENDATIONS-WARNINGS

The use of these products is conditioned by the indications. Although the product is not defined as a single-use 

device, using it on a single patient only is recommended and only for the intended purposes as described in 

these instructions or by a healthcare professional.

When disposing of the product and its packaging, you must strictly adhere to the legal regulations in your 

community.
RECOMMENDATIONS FOR STORAGE AND WASHING

When not using the product, store it in the original packaging in a dry place at room temperature. Stick the 

Velcro to each other (if the orthotic device has them), frequently wash by hand with warm water (30º C max.) 

and mild soap. To dry the product, use a dry towel to absorb as much moisture as possible and let it dry at room 

temperature. Do not hang it up or iron the product and do not expose it to direct heat sources such as stoves, 

dryers, direct sun exposure, etc. When using or cleaning the product, do not use abrasive or corrosive substanc-

es, alcohol, ointments or liquid solvents. If not dried off properly, the detergent residue may irritate the skin 

and cause the product to deteriorate. 

t o y m U

Содержание OP1172

Страница 1: ...ello y debe asegurarse que el usuario final o la persona responsable de la colocaci n del producto entiende correctamente su funcionamiento y su utilizaci n Para su colocaci n deben observarse los si...

Страница 2: ...er or person responsible for fitting the product properly understands how it works and should be used When fitting the product you must adhere to the following instructions 1 Place the belt around the...

Страница 3: ...uit comprend correctement son fonctionnement et son utilisation Pour mettre en place le produit veuillez suivre les instructions suivantes 1 Placez la ceinture autour de la r gion pelvienne du patient...

Страница 4: ...n hat F r die Positionierung sind die folgenden Aspekte zu beachten 1 Befestigen Sie das Korsett um den Beckenbereich des Patienten sodass es den R cken und den Bauch umschlie t 2 Passen Sie die Gurte...

Страница 5: ...spons vel pela coloca o do produto entende corretamente o seu funcionamento e a sua utiliza o Para a sua coloca o devem ser observados os seguintes aspetos 1 Coloque a faixa em redor da regi o p lvica...

Страница 6: ...ar necessario assicurarsi che l utente finale o la persona responsabile della collocazione del prodotto ne comprenda correttamente il funzionamento e l uso Per la collocazione necessario adottare le s...

Страница 7: ...ba odpowiedzialna za umieszczenie wyrobu posiada odpowiedni wiedz na temat jego obs ugi i u ytkowania Podczas zak adania nale y zwr ci uwag na nast puj ce aspekty 1 Za o y pas wok plec w i brzucha na...

Страница 8: ...de eindgebruiker of de persoon die verantwoordelijk is voor het plaatsen van het product de werking en het gebruik ervan goed te begrijpen Bij plaatsing dienen de volgende aspecten in acht te worden g...

Страница 9: ...sigure c utilizatorul final sau persoana responsabil pentru aplicarea produsului n elege corect func ionarea i utilizarea acestuia Pentru aplicarea produsului trebuie s se in seama de urm toarele aspe...

Страница 10: ...275 87 00 Tel Exportaci n 34 96 274 23 33 E mail orto orliman com Export mail export orliman com www orliman com OP1172 Fecha de emisi n Date of issue 2021 09 Fecha de revisi n Revision date 2022 02 v...

Страница 11: ...g re dette og det skal sikres at slutbrugeren eller den ansvarlige for anbringelse af produktet har en korrekt forst else for dets funktion og anvendelse Ved anbringelsen skal der tages hensyn til f...

Страница 12: ...liman com Export mail export orliman com www orliman com OP1172 Fecha de emisi n Date of issue 2021 09 Fecha de revisi n Revision date 2022 02 v 02 Ref OP1172 marca INSTRUCCIONES DE COLOCACI N FITTING...

Отзывы: