Symptom
Reason
Action
Alarm: No fire/fuel Lack of fire
Refill hopper acc. to point „Lightning up”
Boiler
cannot reach
programmed
temp.
Wrong lightning up
Check „Lightning up”
Too moisture pellet
Check moisture – use pellet with required
parameters
Clogged primary air channels
Call service – after-warranty service
Clogged heat exchanger’s pipes
Clean pipes or call service – after warranty
service
Damaged gasket on blower’s or
burner’s flange
Replace – after-warranty service
Damaged blower
Replace – after-warranty service
Boiler is fuming
Clogged or unproper chimney
Get the chimney-sweeper opinion
Strong wind forces fumes into the
chimney
Consider installation of devices regulating
chimney draught
Door is fuming
Gasket leak
Regulate the door’s hinges
Damaged rope
Replace the rope – after-warranty service
Controller doesn’t
work
No voltage in the grid
Check the protection devices in the electric
installation
Damaged wire
Wire and connection control
Damaged controller
Call the service
Loud blower
operation
Damaged bearings
Call the service - replace the blower
Damaged capacitor
Call service – replace the capacitor
Loosen fixing of blower
Fixing control, screw in
Dirty rotor blades
Control, cleaning
24
25
10. Troubleshooting