background image

12

Object?” Press ENTER to slew the telescope to the 
coordinates. Press ESC to exit.

Selecting a user defined object

1.  Press the USER shortcut key. The screen will display 

“User Object / Recall Object”. Press ENTER.

2.  2. Use the scroll keys to browse through the list of 

pre-defined objects indexed from 1 to 25. Select the 
number representing the object you wish to view, 
then press ENTER to display the object’s coordinates. 
Press the ENTER key again to proceed.

3.  The screen will now display “View Object?”

•  Press ENTER to slew the telescope to the selected 

object.

•  Press ESC to exit.

5.  Configuring Hand 

Controller and 

Mount Settings

The SETUP shortcut key is the entry point for configuring 
many aspects of the mount and hand controller. The different 
types of functions available are listed below, along with their 
respective purposes. Press the SETUP key to access them.

5.1 Date, Time, Site, Time Zone, and Daylight 

Saving Time

1.  Date – Allows you to change the date entered at the 

initial setup.

2.  Time – Allows you to change the current time.
3.  Observing Site – Allows you to change the current 

location settings.

4.  Daylight Saving – Allows you to change the Daylight 

Saving option.

5.  Alignment – Allows you to re-perform the 1-star, 

2-star, or 3-star alignment for GoTo operation with out 
restarting the mount.

5.2 Hand Controller Display, Keypad, and Beeper

1.  Access the menu “Setup \ Handset Setting” and press 

the ENTER key.

2.  Use the scroll keys to select “LCD Contrast,” then use 

the left/right direction keys to adjust the contrast of the 
LCD text characters.

3.  Use the scroll keys to select “Beep Volume,” then use 

the left/right direction keys to adjust the volume of the 
beeper.

4.  Use the scroll keys to select “LED Backlight,” then 

use the left/right direction keys to adjust the LED 
brightness of the hand controller keys (buttons).

5.  Use the scroll keys to select “LCD Backlight,” then use 

the left/right direction keys to adjust the brightness of 
the LCD screen’s backlight.

6.  Press ESC to exit the adjustment.

5.3 Backlash Compensation

Backlash is a delay in motorized motion of the mount due to 
slack between gears. This delay, or hesitation, is experienced 
when the slewing direction is reversed on one or both axes 
of motion using the direction keys on the hand controller. So 
when you’re looking at an object in the eyepiece, it will not 
move immediately upon pressing a direction key – there will 
be a lag time.
The SynScan hand controller can compensate for backlash by 
commanding the mount to slew at a higher speed for a specific 
amount of distance when the user revers es direction with the 
direction keys. With such backlash compensation you’ll get a 
faster response from the mount.
This function allows you to insert a value for each axis to com-
pensate for slewing backlash experienced on that axis. For 
improved pointing accuracy, it is important that the backlash 
value is set to be equal or greater than the actual amount of 
backlash between the gears. If the actual amount of backlash 
is unknown, we recommend that you set the value to 5000 
(approximately equivalent to 0.2°). First set the value for R.A. 
backlash, then press ENTER to set the value for DEC.
•  Access the menu “SETUP / Backlash” and press the 

ENTER key.

•  The screen will display “Azm = XoXX’XX” ” or “RA = 

XoXX’XX” ”. Use the Left/Right keys to move the cursor 
and use the numeric keys to fill in a number at the cursor 
position to input the amount of backlash in the azimuth 
or R.A. axis. Press the ENTER key to finish the input and 
proceed to the next step.

•  The screen will display “Alt = XoXX’XX” ” or “Dec = 

XoXX’XX” ”. Fill in the amount of backlash in the altitude 
axis or Dec. axis and then press the ENTER key.

 Notes: 

•  Set the backlash value to 0 for an axis to disable 

backlash compensation for that axis.

•  Backlash compensation is only active for computerized 

GoTo slewing, not for manual slewing with the direction 
buttons.

5.4 Tracking rate

The mount can track at several different rates, which you 
select depending on the type of object(s) you’ll be observing 
or photographing.

1.  Access the menu “SETUP \ Tracking” and press the 

ENTER key.

2.  Use the scroll keys to browse the various options, and 

press the ENTER key to pick one.

•  Sidereal Rate: 

This is the default tracking rate. Activates 

tracking at sidereal rate (R.A. tracking) for observing/
photographing stars, deep-sky objects, and planets.

•  Lunar Rate: Activates tracking at lunar rate (R.A. tracking) 

for observing/photographing the Moon.

•  Solar Rate: Activates tracking at solar rate (R.A. tracking) 

for observing/photographing the Sun.

Содержание SynScan GoTo

Страница 1: ...t 800 676 1343 E mail support telescope com Corporate Offices 831 763 7000 89 Hangar Way Watsonville CA 95076 Providing Exceptional Consumer Optical Products Since 1975 SynScan GoTo Hand Controller IN...

Страница 2: ...Variable Stars 11 4 4 SAO Stars 11 4 5 Deep Sky Tour 11 4 6 User Defined Objects 11 5 Configuring Hand Controller and Mount Settings 12 5 1 Date Time Site Time Zone and Daylight Saving Time 12 5 2 Han...

Страница 3: ...s slewing to an object The direction keys are very helpful when initially aligning the mount centering objects in the eyepiece field of view slewing and manually guiding The left and right direction k...

Страница 4: ...ost recent speed will be kept and the LCD display will return to its previous content The following table lists the available slewing speeds Rate No 0 1 2 3 4 5 6 7 8 9 Speed 1 0 5X 2 1X 3 8X 16X 32X...

Страница 5: ...It automatically detects the model of the mount to which it con nects and selects the appropriate operation mode accordingly For an Equatorial Alt azimuth dual mode mount such as the Orion Atlas Pro A...

Страница 6: ...ro cess the screen will display Begin Alignment and ask you to select 1 YES or 2 NO Press 1 to start the alignment process The SynScan hand controller will operate in Full Feature mode refer to Sectio...

Страница 7: ...t be performed again To do this turn the mount s power switch off then on again 2 Star Alignment Two star alignment requires only two alignment stars but may produce lesser pointing accuracy than the...

Страница 8: ...the selected region the hand controller will display No object found in this region Press ENTER or ESC and select another region of sky 4 Now use the Scroll keys to scroll through the list of bright s...

Страница 9: ...at the hand controller will not prompt you to select a directional region for a bright star Instead you ll be presented with a list of stars available in your current sky to choose from for each of th...

Страница 10: ...other 8 planets of our solar system and Earth s Moon NGC 7 840 of the brightest deep sky objects from the Revised New General Catalog IC 5 386 of standard stars and deep sky objects from the Indexed...

Страница 11: ...4 5 Deep Sky Tour The SynScan hand controller enables you to take a tour of the best deep sky objects visible in the current sky from your location You can select them one by one and command the SynSc...

Страница 12: ...direction is reversed on one or both axes of motion using the direction keys on the hand controller So when you re looking at an object in the eyepiece it will not move immediately upon pressing a dir...

Страница 13: ...o end the input and proceed The screen will display Lower XXX Xo at the bottom row fill in the data in a similar way 5 7 Enable Disable Auxiliary Encoder Some Orion telescopes and mounts are equipped...

Страница 14: ...ignment is which will allow you to decide if you should perform the polar alignment procedure again or if it s good enough for your purpose Access the menu Utility Func Show Information P A Error and...

Страница 15: ...or may vary in different portions of the sky The SynScan hand controller divides the sky into 85 small zones and you can calibrate the pointing error for each of these zones The next time the SynScan...

Страница 16: ...sure time in minutes and seconds and the last 3 digits are the number of frames to be shot up to 999 Press the ENTER key to pick a group and proceed to the next step 4 The first row of the screenshot...

Страница 17: ...een will display Select Speed 1 0 125X 2 0 25X This is the speed used to move the star in the FOV of the telescope when you press the Left or Right direction key on the SynScan hand controller Choosin...

Страница 18: ...mm ss You can then use the data to determine whether or not to adjust the azimuth of the mount Press the ENTER key again to proceed to the next step 8 The mount will slew to a new position When it st...

Страница 19: ...r at the bottom of the window to show the progress 5 Once update is complete the application will display a green bar with Update Complete at the bottom of the window 8 4 Troubleshooting 1 If a window...

Страница 20: ...and controller Place the GPS module on a horizontal surface 2 Access the menu Utility Func GPS and press the ENTER key 3 The screen will now display GPS fixing as the GPS module is attempting to fix o...

Страница 21: ...21 Appendix A Standard Time Zones of the World...

Страница 22: ...lign Polar Align Brightest Star SETUP MODE Show Position Show Information Identify Park Scope PAE GPS PC Direct Mode Polar Scope LED PEC Training Camera Control Adv Filter Sort By Time Version Tempera...

Страница 23: ...ith the optical tube of the telescope Note Steps 2 to 4 are to identify R A and Dec move ments of stars in the reticle eyepiece If you are already familiar with the movements proceed to step 5 2 Find...

Страница 24: ...center of the eyepiece by HALF not all the way 13 Repeat Steps 8 and 9 to check whether the cone error is now acceptable Repeat Steps 10 11 and 12 if necessary until Polaris remains in the center of...

Страница 25: ...res The screen will display Key in the top row If a key is pressed the name of the key will be displayed and the hand controller beeps The power voltage and the temperature will be displayed on the bo...

Страница 26: ...A C O B ig D ip p e r T A U R U S B e t e l g e u s e L i t t l e D i p p e r P o i n t e r s P o l a r i s U R S A M A J O R C a s t o r C a p e l l a P r o c y o n C Y G N U S L E O M I N O R H E R...

Страница 27: ...i p p e r P o l a r i s U R S A M A J O R C O M A B E R E N I C E S C Y G N U S P I S C E S P I S C E S P E G A S U S L E O M I N O R HERCULES OPHIUCHUS SCORPIUS TELESCOPIUM C O R O N A B O R E A L I...

Страница 28: ...I D A N U S PHOENIX PISCIS AUSTRINUS CAPRICORN U S MICROSCOPIUM AQUARIUS O P H I U C H U S V U L P E C U L A S A G I T T A H E R C U L E S U R S A M I N O R C E P H E U S C A S S I O P E I A C A M E...

Страница 29: ...ONOCEROS Alphard LEPUS COLUMBA CAELUM B O T E S U R S A M I N O R C E P H E U S C A S S I O P E I A C A M E L O P A R D A L I S GEMINI M i r f a k H YDRA PYXIS ANTLIA M I N O R C A N I S MAJOR CANIS D...

Страница 30: ...rranted instrument that proves to be defective provided it is returned postage paid Proof of purchase such as a copy of the original receipt is required This warranty is only valid in the country of p...

Отзывы: