WARNING:

The operating instructions shall draw attention to the following

a)

Only those fasteners listed in the operating instructions may be used in the fastener driving

tools;

NOTE:

The fastener driving tool and the fasteners listed in the operating instructions must be

seen as one unit system in terms of technical safety.

b)

Only the main energy and the lubricants listed in the operating instructions may be used;

c)

Fastener driving tools marked with an inverted equilateral triangle standing on one point

may only be used with an effective safety yoke;

d)

Fastener driving tools equipped with contact actuation or continuous contact actuation,

marked with the symbol “Do not use on scaffoldings, ladders”, shall not be used for specific

application for example:

when changing one driving location to another involves the use of scaffoldings, stairs, ladders,

or ladder alike constructions, e.g. roof laths, closing boxes or crates, fitting transportation

safety systems e.g. on vehicles and wagons;

e)

For the maintenance of fastener driving tools, only spare parts specified by the

manufacturer or his authorized representative shall be used;

f)

Repairs shall be carried out only by agents authorized by the manufacturer or by other

specialists, having due regard to the information given in the operating instructions;

NOTE:

Specialists are those who, as a result of professional training or experience, have

sufficient expertise in the field of fastener driving tools and sufficient familiarity with relevant

governmental industrial protection provisions, accident prevention regulations, directives and

generally recognized technical regulations (e.g. CEN- and CENELEC-standards), to be able to

assess the safe working condition of fastener driving tools.

g)

Stands for mounting the fastener driving tools to a support for example a work table, shall

be designed and constructed by the stand manufacturer, in such a way that the fastener

driving tool can be safely fixed for the intended use, thus for example avoiding damage,

distortion or displacement.

Additional instructions for fastener driving tools operated by compressed air

a)

Fastener driving tools operated by compressed air shall only be connected to compressed

air lines where the maximum allowable pressure cannot be exceeded by a factor of more than

10%, which can for example be achieved by a pressure reduction valve which includes a

downstream safety valve;

b)

When using fastener driving tools operated by compressed air, particular attention must be

paid to avoid exceeding the maximum allowable pressure;

c)

Fastener driving tools operated by compressed air should only be operated at the lowest

pressure required for the work process at hand, in order to prevent unnecessarily high noise

levels, increased wear and resulting failures;

d)

Hazards caused by fire and explosion when using oxygen or combustible gases for

operating compressed air operated fastener driving tools.

Содержание CN80F

Страница 1: ...understand the instructions in this manual before operating the pneumatic power tool Carefully read through this OPERATOR S MANUAL to ensure efficient safe operation It is recommended that the Manual...

Страница 2: ...ilers are caused by the failure to observe basic safety rules or precautions An accident can often be avoided by recognizing a potentially hazardous situation before it occurs and by observing appropr...

Страница 3: ...ssional training or experience have sufficient expertise in the field of fastener driving tools and sufficient familiarity with relevant governmental industrial protection provisions accident preventi...

Страница 4: ...els which can lead to hearing damage the employer and user should ensure that any necessary hearing protection is provided and used by the operator and others in the work area 3 DO NOT USE ANY POWER S...

Страница 5: ...enever the air supply is connected to the tool never touch the trigger unless you intend to drive a fastener into the work It is dangerous to walk around carrying the tool with the trigger pulled and...

Страница 6: ...may result Do not interfere with the proper operation of the contact trip mechanism 18 WHEN USING THE TOOL OUTSIDE OR ELEVATED PLACE When fastening roofs or similar slanted surface start fastening at...

Страница 7: ...ation mode Contact actuation Magazine capacity 225 300 nails Maximum allowable pressure 120psi 8 3bar Recommended pressure range 70psi to 100psi 5bar to 7bar Fasteners Only the nail sizes shown in the...

Страница 8: ...ly compressed air to this nailer Moisture or oil in the air compressor may accelerate wear and corrosion in the nailer Drain daily Connections 1 Fittings Install a female coupler to the hose The femal...

Страница 9: ...ood are factors in determining what the pressure should be set at Do not exceed this recommended operating pressure NOTE Dirt and water in the air supply are major causes of wear in the tool An air fi...

Страница 10: ...g the hands or body by mistake Nail loading 1 Disconnect the air hose 2 Press LATCH 210070 to open DOOR 210050 then open MAGAZINE COVER 420190 3 Adjust the height of NAIL SUPPORT 420210 according to n...

Страница 11: ...he nailer rail with nailer lubricant Clearing a jam Remove a jammed nail in the following order 1 DISCONNECT AIR HOSE 2 Remove all nails 3 Remove the jammed nail with a slotted head screwdriver 4 In c...

Страница 12: ...26 410120 BUMPER B 80 110030 END CAP 27 610330 NUT M6 Nylock 81 510760 O RING 58X3 55 28 420180 GUARD COVER 82 630020 SNAP RING 52 29 324860 SAFETY 83 420190 MAGAZINE COVER 30 620100 SAFETY SPRING 84...

Страница 13: ...TOOL SCHEMATIC CN80F...

Страница 14: ...CN80F Construction Coil Nailer 1701...

Отзывы: