Weight Capacity

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Warning Statements

 

The wall, floor or ceiling should be capable of supporting a weight of at least five (5) 
times the monitor’s weight. If it cannot, the wall, floor or ceiling must be reinforced. 
Proper installation procedure by qualified personnel as outlined in the installation 
instructions must be adhered to Failure to do so could result in serious personal injury. 

CAUTION! 

The entire installation instructions should be fully read and understood, 

including all of the safety symbols and safety precautions before beginning installation. 
The installation instructions should be read, understood and followed to prevent 
personal injury or proper damage. Keep these installation instructions in an easily 
accessible location for future reference. 

CAUTION! 

The ceiling structure must be capable of supporting a maximum weight of 

400 lbs. If not, the ceiling must be reinforced. Proper installation procedure by qualified 
personnel as outlined in the installation instructions must be adhered to. Failure to do 
so could result is serious personal injury. 

CAUTION! 

Make sure to hold the plasma display, or projector, securely and remove it 

from the mount to make the height adjustment prior to loosening the adjustment 
screws. Do not remove the screws completely from the extension loosen all at once. 
Loosen, remove, adjust then re-tighten the screws. Failure to do so could result in 
injury and or damage to the plasma display or projector. 

Indicates that the power plug is to be disconnected from the power outlet. 

Safety precautions must be taken at all times. 

Warning and caution in general 

Maximum flat panel weight: 

160lbs 

THE CEILING STRUCTURE MUST BE CAPABLE OF 
HOLDING FIVE (5) TIMES THE WEIGHT OF THE 
FLAT PANEL AND MOUNT. IF NOT, THEN THE 
CEILING STRUCTURE MUST BE REINFORCED. 

Содержание CMH-01

Страница 1: ...ww orionimages com All contents of this document may change without prior notice and actual product appearance may differ from that depicted herein Installation and User s Guide CMH 01 Elliptical Ceiling Mount FLAT LCD DISPLAY MOUNT MODEL ...

Страница 2: ...ssible location for future reference CAUTION The ceiling structure must be capable of supporting a maximum weight of 400 lbs If not the ceiling must be reinforced Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to Failure to do so could result is serious personal injury CAUTION Make sure to hold the plasma display or projector secur...

Страница 3: ...66 6310 pg3 TABLE OF CONTENTS 1 PART LIST 2 1 Attaching CMH 01 to the Ceiling Adapter 2 FEATURE 2 2 Selecting the Appropriate Mounting Hardware 2 3 Griplate Washer Installation 3 FLAT PANEL INSTALLATION 4 ATTACHING DECORATIVE COVERS 5 TILT POSITIONING 6 TECHNICAL SPECIFICATIONS 7 LIMITED WARRANTY 4 5 7 6 8 9 10 11 12 13 14 ...

Страница 4: ...r installation hardware and components Make sure that none of these parts are missing and or damaged before beginning installation If there are parts missing and or damaged please stop the installation and contact ORION Images 714 766 6300 Elliptical Tilt Mount Qty 1 Decorative Covers Qty 2 Griplate Washers Qty 8 Thread Depth Indicator Qty 1 M6 x 25mm Phillips Screw Qty 2 M4 x 6mm Phillips Screw Q...

Страница 5: ...s Head Screw Qty 6 M5 x 16mm Phillips Head Screw Qty 6 M8 x 25mm Phillips Head Screw Qty 6 M5 x 20mm Phillips Head Screw Qty 6 M8 x 30mm Phillips Head Screw Qty 6 M5 x 25mm Phillips Head Screw Qty 4 M8 x 35mm Phillips Head Screw Qty 4 M5 x 50mm Phillips Head Screw Qty 4 M8 x 70mm Phillips Head Screw Qty 4 M6 x 12mm Phillips Head Screw Qty 8 1 2 Nylon Spacers Large Qty 12 9 16 Nylon Spacers Qty 6 1...

Страница 6: ...http www orionimages com 7300 Bolsa Avenue Westminster CA 92683 Tel 714 766 6300 Fax 714 766 6310 pg6 Features 1 Threaded Pipe Phillips Set Screw 1 Threaded Coupler 15 Tilt Slide Decorative Cover Cable Access Port Mounting Bracket Arm ...

Страница 7: ...ng steps 1 Align the CMH 01 threaded coupler with the threaded end of the 1 1 2 threaded pipe 2 Threaded the CMH 01 onto the 1 1 2 threaded pipe and rotate the CMH 01 coupler clockwise until the coupler is fully threaded onto the 1 1 2 theaded pipe The coupler must be threaded onto the 1 threaded pipe a minimum of four 4 complete turns Step2 Once the CMH 01 has been firmly threaded to the 1 thread...

Страница 8: ...orrect diameter screw for the thread insert 5 Test each size of the screws provided If the screw you selected is longer than the mark on the Thread Depth Indicator as shown in Figure 2 and Figure 3 do not use this screw The screw length must not bypass the mark Select another screw length until you fi nd a screw that comes closest to the mark without going past the mark The correct screws should t...

Страница 9: ... mounting bracket as shown Does your flat panel have z Recessed mount points z Uneven mount points z A curved back z Any obstruction near the mount point If Yes you must install nylon spacers Remove the mounting brackets Griplate washers and mounting screws from the back of the fl at panel Proceed to the Nylon Spacer Installation section Nylon Spacer Installation Nylon spacers allow you to attach ...

Страница 10: ...sting on the elliptical mounting bar Raise the mounting bracket arms and the attached flat panel over the elliptical mounting bar of the CMH 01 The cable access ports face the rear of the flat panel It may be easier to pre wire any cables prior to flat panel installation see Page 10 Mounting Bracket Arms Elliptical Mounting Bar Lower and center the mounting bracket arms with the attached fl at pan...

Страница 11: ... mounting bracket arm Step2 1 Align the mounting holes 2 Insert and tighten a M4 x 6mm Phillips screw smaller mounting hole 3 Insert and tighten a M6 x 25mm Phillips screw larger mounting hole 4 Repeat Step 2 and 3 for the second decorative cover and mounting bracket arm Cable Management Route cables through the cable access holes and to their respective locations The cables must then be routed th...

Страница 12: ... fl at panel 3 Using the upper hand gently push the top of the fl at panel towards the wall while the lower hand gently pulls the bottom of the flat panel away from the wall If additional tilt friction is required tighten the lower nut and lower bolt only to increase the tilt friction Lower Bolt Lower Nut Optional Mounting Configuration and Accessories The CMH 01is designed for use with either a s...

Страница 13: ...13 Installation and User s Guide http www orionimages com 7300 Bolsa Avenue Westminster CA 92683 Tel 714 766 6300 Fax 714 766 6310 pg13 Technical Specification All measurements are in inches ...

Страница 14: ...gainst defects in materials and workmanship Orion Images is not liable for improper installation that results in damage to mounts adapters display equipment or personal injury In the event of missing and or damage equipment or technical questions the following information can help in the completion of the installation Address 7300 Bolsa Avenue Westminster CA 92683 Tel 714 766 6300 Fax 714 766 6310...

Отзывы: