background image

13

WIRELESS AUTODIAL 

HOME ALARM SYSTEM 

AM2000

IMPORTANT – 

WHEN THE ZONE SETTING 

IS CHANGED, THE SENSOR MUST RE-PAIR 

WITH AM2000 CONTROL PANEL.

HOME MODE  

ZONE

NORMAL  

ZONE

SINGLE DELAY  

ZONE

TAMPER 

SWITCH

ZONE SETUP

LED ON/OFF

SENSOR

HOME MODE ZONE

 – when home mode 

button is pressed on AM2000 control panel 

or the remote control, it will not trigger the 

alarm, and therefore occupants can move 

freely inside the room. Meanwhile other zone 

setting will remain armed. 

NORMAL ZONE

 – when AM2000 is armed,  

if intruder detected, it will trigger alarm 

immediately.

SINGLE DELAY ZONE

 – when AM2000 is 

armed, if intruder detected, it will trigger alarm 

after 30 seconds time delay in default settings.

NOTE:

 

AM2010 PIR motion sensor is set to 

“HOME MODE ZONE” by default.

Open the case with a screw driver and remove 

the battery insulation strip to power on the sensor.  

Once the sensor is powered on, it will start  

self testing for one minute.

TESTING MODE:

 After self testing, press 

the test button on the rear of the sensor, the 

sensor enters into testing mode, and detects 

once every 10 seconds, walk within the 

detection range, from left to right or right to 

left and monitor the LED indicator to ensure 

the detector is working.
Adjust the sensor angle accordingly to achieve 

best detection effect. After 3 minutes, the LED 

flashes twice, and the sensor enters working 

mode.

WORKING MODE:

 in working mode, if the 

sensor is triggered more than twice within  

3 minutes, it will enter standby mode to save 

power. After no movement within next 3 minutes, 

the sensor goes back to the working mode.

› 

Pairing with AM2000 control panel

Key in the password and press the connect 

key on AM2000 control panel, and then press 

the test button twice on the back of the sensor 

unit. When one beep sound from the AM2000 

control panel is heard, they are paired.
To check if they are connected successfully, 

arm the AM2000 control panel, trigger the 

sensor by walking within the detection range 

after exit delay time; if there is an alarm, the 

connection is successful.

› 

LED indication

FLASH CONTINUOUSLY 

–  

under self testing mode.

FLASH ONCE

 – intruder detected.

FLASH TWICE

 – self testing mode completed, 

enter to working mode.

FLASH ONCE PER 3 SECONDS

 – low battery  

indication, please change batteries immediately, 

user will get alert SMS for low battery if the PIR 

motion sensor is connected to AM2000 control 

panel with GSM enabled.

4.4 

 

OPERATION

Содержание AM2000

Страница 1: ...PROFESSIONAL SECURITY SYSTEM INSTRUCTIONS FOR USE IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY AM2000 WIRELESS AUTODIAL HOME ALARM SYSTEM ...

Страница 2: ...com au For further information visit www orionlive com au PLEASE CONTACT IF YOU HAVE ANY CONCERNS OR PROBLEMS WITH THIS PRODUCT IMPORTANT BEFORE RETURNING THIS PRODUCT TO THE RETAILER CONTENTS ALARM PANEL 2 X DOOR WINDOW CONTACT SENSORS POWER SUPPLY DETERRENT STICKERS MOUNTING SCREWS PLUGS AND BRACKETS USER MANUAL 2 X PIR MOTION SENSORS 2 X REMOTE CONTROLS 2 X RFID TAGS WIRELESS AUTODIAL WIRELESS ...

Страница 3: ...Reader area to disarm the system GSM SIGNAL INDICATOR GSM Networking searching Flashes once every second GSM signal normal Flashes once every 2 seconds IMPORTANT A SIM card is required to access most functions of AM2000 Home Alarm System 1 Restart the alarm panel after inserting a new SIM card 2 SIM card not included Please use a valid SIM card that is compatible to the GSM network with sufficient...

Страница 4: ...ensor c Remote Control Press any button on the remote control d RFID Tag Wave RFID tag near alarm panel RFID reader 4 Connection successful when alarm panel beeps once NOTE If alarm panel beeps twice accessory has been added before Alarm panel assigns zones sequentially The first connected accessory is assigned in Zone 1 the second one in Zone 2 and so on Alarm panel supports up to 10 remote contr...

Страница 5: ...icator flashes every two seconds network connection is established NOTE Please check credit on the SIM card account periodically to ensure the GSM SMS functionality operates correctly Send a text of to the SIM card number the operation guide message will be replied You can control the alarm system by following the guide message Send System replies first grade guide menu Send System replies second ...

Страница 6: ... is triggered Send Forward Edit 00 5 2 14 SETTINGS INQUIRY 2 15 STORE ALARM PHONE NO 2 3 4 Send Send Send 3 to the SIM card number the alarm will call back Pick up the phone and start two way talk Send Send 4 to the SIM card number the alarm will call back Pick up the phone and leave 10 seconds message The panel will hang up after 10 seconds 2 11 STAY ARM HOME MODE 2 12 TWO WAY TALK 2 13 CALL BACK...

Страница 7: ...arm system Press 0 Disarm alarm system Press 9 Turn on siren to deter intruder Press 6 Turn off siren Press Two way talk between phone and alarm panel Press Replay recorded alarm voice message This alarm voice message will be played when user picks up alarm phone call 1 Enter alarm panel password Default 1234 2 Press Home button then press Record button 3 After the button illuminates the alarm pan...

Страница 8: ...ber low battery Available for AM2010 AM2020 and AM2030 SMS will be sent for 1 9 zones with its zone name as Zone name tamper alarm SMS alert for 10 50 zones will be Zone number tamper alarm 2 21 CHANGE ZONE NAME 2 22 SMS ALERT FOR LOW BATTERY OF ACCESSORIES 7 8 2 19 STORE SMS NO FOR RFID TAGS Alarm panel sends SMS notification to stored phone number when system is disarmed using RFID tag Send Forw...

Страница 9: ...hout the use of remote control and RFID tag After pressing Arm Button the alarm panel will change to Armed state after this delay time This allows the user to exit the premises without triggering the alarm Alarm will beep every second to remind user to exit premises The reminder beep speeds up in the last 15 seconds If intruder is detected the alarm is delayed based on this delay time 10 11 Send F...

Страница 10: ...IES BY SMS 14 0086 0001 When a sensor which is set to Single Zone Delay mode detects intruder alarm panel will only trigger alarm after this delay time Send Forward Edit Send 0086 to change language to Chinese Send 0001 to change language to English 13 Send Forward Edit 2 27 CHANGE DISARM PASSWORD 2 28 SINGLE ZONE DELAY TIME 2 29 CHANGE SYSTEM LANGUAGE NOTE It is recommended to change alarm panel ...

Страница 11: ... and button illuminates the system is disarmed When intruders are detected siren will keep hooting Press Disarm to stop siren hooting Home Mode Press Home to arm the home mode All the sensors in Normal Zone are armed except those in Home Mode Zone which are disarmed so that user can move freely at home Mute Mode Press Home button on the remote control then press Arm or Disarm button the siren keep...

Страница 12: ...en it is positioned to one side of a walkway SENSOR detects the motion of infra red rays released by human body and animals or heat sources Do not touch the sensor and always keep the detection window clean TAMPER SWITCH when the case is opened during armed state the tamper switch will be triggered and generate a signal to alarm the AM2000 control panel LED ON OFF set the jumper to ON or OFF posit...

Страница 13: ...ction range from left to right or right to left and monitor the LED indicator to ensure the detector is working Adjust the sensor angle accordingly to achieve best detection effect After 3 minutes the LED flashes twice and the sensor enters working mode WORKING MODE in working mode if the sensor is triggered more than twice within 3 minutes it will enter standby mode to save power After no movemen...

Страница 14: ...hen trigger the sensor by opening the door it is mounted on When one beep sound from the AM2000 control panel is heard they are paired To check if they are connected successfully arm the AM2000 control panel trigger the sensor unit by opening the door it is mounted on if there is an alarm the connection is successful 5 1 INSTALLATION AND NOTICES 5 2 INTERNAL AND FUNCTIONS 5 3 OPERATION IMPORTANT W...

Страница 15: ... CONTACT SENSOR Power Supply DC 1 5V AA Alkaline Battery Included Power Consumption 0 06W Max Wireless Range Up to 50m Radio Frequency 433MHz Operating Temperature 10 C 55 C Operating Humidity 80 Dimensions Sensor 71 L x 34 W x 17 5 H mm Magnet 51 L x 12 W x 13 5 H mm 7 WARNING Do not drop puncture or violently shake the unit Do not mount directly expose or put near to the sun water air conditione...

Страница 16: ...replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Arlec Australia Pty Ltd ACN 009 322 105 Arlec gives the Warranty Arlec s telephone number address and email address are Custome...

Отзывы: