background image

The Dec. setting circle is scaled in degrees, with each mark
representing 2° increments. Values of declination coordinates
range from +90° to -90°. The 0° mark indicates the celestial
equator. When the telescope is pointed north of the celestial
equator, values of the declination setting circle are positive;
when the telescope is pointed south of the celestial equator,
values of the declination setting circle are negative.

So, the coordinates for the Orion Nebula listed in a star atlas
will look like this:

R.A. 5h 35.4m Dec. –5° 27'

That’s 5 hours and 35.4 minutes in right ascension, and -5
degrees and 27 arc-minutes in declination (there are 60 arc-
minutes in 1 degree of declination).

Before you can use the setting circles to locate objects, the
mount must be accurately polar aligned, and the setting cir-
cles must be calibrated.

Calibrating the Declination Setting Circle

1. Loosen the Dec. lock lever and position the telescope as

accurately as possible in declination so it is parallel to the
R.A. axis as shown in Figure 1. Re-tighten the lock lever.

2. Loosen one of the thumbscrews on the Dec. setting circle

(see Figure 11), this will allow the setting circle to rotate
freely. Rotate the Dec. setting circle until the pointer reads
exactly 90°. Re-tighten the setting circle thumbscrew.

Calibrating the Right Ascension Setting Circle

1. Identify a bright star in the sky near the celestial equator

(declination = 0°) and look up its coordinates in a star
atlas.

2. Loosen the R.A. and Dec. lock levers on the equatorial

mount, so the telescope optical tube can move freely.

3. Point the telescope at the bright star whose coordinates

you know. Lock the R.A. and Dec. lock levers. Center the
star in the telescope’s field of view with the slow-motion
control knobs.

4. Loosen one of the R.A. setting circle thumbscrews (see

Figure 11); this will allow the setting circle to rotate freely.

Rotate the setting circle until the R.A. pointer arrow indi-
cates the R.A. coordinate listed in the star atlas for the
object. Re-tighten the setting circle thumbscrew.

Finding Objects With the Setting Circles

Now that both setting circles are calibrated, look up in a star
atlas the coordinates of an object you wish to view.

Loosen the Dec. lock lever and rotate the telescope until the
declination value from the star atlas matches the reading on
the Dec. setting circle. Remember that values of the Dec. set-
ting circle are positive when the telescope is pointing north of
the celestial equator (Dec. = 0°), and negative when the tele-
scope is pointing south of the celestial equator. Retighten the
lock lever.

Loosen the R.A. lock lever and rotate the telescope until the
right ascension value from the star atlas matches the reading
on the R.A. setting circle. Remember to use the lower set of
numbers on the R.A. setting circle. Retighten the lock lever.

Most setting circles are not accurate enough to put an object
dead-center in the telescope’s eyepiece, but they should
place the object somewhere within the field of view of the find-
er scope, assuming the equatorial mount is accurately polar
aligned. Use the slow-motion controls to center the object in
the finder scope, and it should appear in the telescope’s field
of view.

The setting circles must be re-calibrated every time you wish
to locate a new object. Do so by calibrating the setting circles
for the centered object before moving on to the next one.

Confused About Pointing the Telescope?

Beginners occasionally experience some confusion about
how to point the telescope overhead or in other directions. In
Figure 1 the telescope is pointed north as it would be during
polar alignment. The counterweight shaft is oriented down-
ward. But it will not look like that when the telescope is point-
ed in other directions. Let’s say you want to view an object that
is directly overhead, at the zenith. How do you do it?

DO NOT make any adjustment to the latitude adjustment L-
bolts. That will spoil the mount’s polar alignment. Remember,
once the mount is polar aligned, the telescope should be
moved only on the R.A. and Dec. axes. To point the scope
overhead, first loosen the R.A. lock lever and rotate the tele-
scope on the right ascension axis until the counterweight shaft
is horizontal (parallel to the ground). Then loosen the Dec.
lock lever and rotate the telescope until it is pointing straight
overhead. The counterweight shaft is still horizontal. Then
retighten both lock levers.

What if you need to aim the telescope directly north, but at an
object that is nearer to the horizon than Polaris? You can’t do
it with the counterweights down as pictured in Figure 1. Again,
you have to rotate the scope in right ascension so that the
counterweight shaft is positioned horizontally. Then rotate the
scope in declination so it points to where you want it near the
horizon.

Figure 11. 

The R.A. and Dec. setting circles.

11

Dec.
setting circle

Dec.
setting circle
thumbscrew
(2)

Dec.
indicator
arrow

R.A.
indicator
arrow

R.A. setting circle

thumbscrew (2)

R.A.
setting circle

Содержание SkyView Pro 120 EQ 9867

Страница 1: ...roviding Exceptional Consumer Optical Products Since 1975 Customer Support 800 676 1343 E mail support telescope com Corporate Offices 831 763 7000 P O Box 1815 Santa Cruz CA 95061 Orion SkyView Pro 120 EQ 9867 Equatorial Refractor Telescope ...

Страница 2: ...thumbscrew Mounting plate securing knob Counterweight shaft Counterweights Counterweight lock knobs Objective lens Optical tube Tube rings Finder scope Finder scope bracket Eyepiece Star diagonal Focus wheel Right Ascension slow motion control knob Latitude scale Latitude adjustment L bolts Center support shaft Tripod support tray Tripod leg Leg lock knobs ...

Страница 3: ...ar diagonal 1 Finder scope 1 Finder scope bracket with O ring 1 Dust cover 1 Collimation tool 3 Assembly Assembling the telescope for the first time should take about 30 minutes No tools are needed other than the ones provid ed All screws should be tightened securely but be careful not to over tighten or the threads may strip Refer to Figure 1 dur ing the assembly process During assembly and anyti...

Страница 4: ... will go before attaching the shaft Once the shaft is installed turn the casting counter clockwise until the top of the casting is flush with the mount 7 Remove the knurled toe saver retaining screw on the bot tom of the counterweight shaft and slide both counter weights onto the shaft Make sure the counterweight lock knobs are adequately loosened to allow the counterweight shaft to pass through t...

Страница 5: ...cope To ensure smooth movement of the telescope on both axes of the equatorial mount it is imperative that the optical tube is properly balanced We will first balance the telescope with respect to the right ascension R A axis then the declination Dec axis 1 Keeping one hand on the telescope optical tube loosen the R A lock lever Make sure the Dec lock lever is locked for now The telescope should n...

Страница 6: ...scope for proper use To align it first aim the main telescope at an object at least a 1 4 mile away the top of a telephone pole a chimney etc First loosen the R A and Dec lock levers and move the telescope until it is pointing towards the desired object sight along the tube to aim the telescope Turn the focus knob until the object is properly focused Make sure to position the object in the center ...

Страница 7: ... loosened the entire back end of the focuser including any 1 25 diagonal and eyepiece that may be attached comes off exposing the 2 diameter focuser drawtube Now insert your 2 star diagonal into the drawtube and secure with the two thumbscrews loosened previously Insert a 2 eyepiece into the diagonal secure it in place with the thumbscrew on the diagonal and you re ready to observe Note About Chro...

Страница 8: ... to a different viewing location some distance away 3 Loosen the Dec lock lever and rotate the telescope s opti cal tube until it is parallel with the right ascension axis as it is in Figure 6 4 Move the tripod so the telescope tube and right ascension axis point roughly at Polaris If you cannot see Polaris directly from your observing site consult a compass and rotate the tripod so the telescope ...

Страница 9: ...tating the mount about the R A axis You will notice that the object you have previously centered moves in a circular path Use the three alignment setscrews on the polar axis finder to redirect the crosshairs of the polar finder to the apparent center of this circular path Repeat this procedure until the position that the crosshairs point to does not rotate off center when the mount is rotated in R...

Страница 10: ...Figure 9a and thread the entire objective end of the finder inwards or outwards until images appear sharp Re tighten the focus lock ring Once the polar axis finder s objective lens is focused it should not need to be adjusted again Use of the Right Ascension and Declination Slow Motion Control Knobs The right ascension R A and declination Dec slow motion control knobs allow fine adjustment of the ...

Страница 11: ... positive when the telescope is pointing north of the celestial equator Dec 0 and negative when the tele scope is pointing south of the celestial equator Retighten the lock lever Loosen the R A lock lever and rotate the telescope until the right ascension value from the star atlas matches the reading on the R A setting circle Remember to use the lower set of numbers on the R A setting circle Retig...

Страница 12: ... through A good way to judge if the seeing is good or not is to look at bright stars about 40 above the horizon If the stars appear to twinkle the atmosphere is significantly distorting the incom ing light and views at high magnifications will not appear sharp If the stars appear steady and do not twinkle seeing conditions are probably good and higher magnifications will be possible Also seeing co...

Страница 13: ... low magnifications This is because many of them are quite faint yet have some extent apparent width Deep sky objects will often disappear at higher magnifications since greater magnification inherently yields dimmer images This is not the case for all deep sky objects however Many galaxies are quite small yet are somewhat bright so higher power may show more detail The best rule of thumb with eye...

Страница 14: ...cts to appear like the photographs you see in books and magazines most will look like dim gray smudges But as you become more experienced and your observing skills get sharper you will be able to ferret out more and more subtle details and structure How to Find Deep sky Objects Starhopping Starhopping as it is called by astronomers is perhaps the simplest way to hunt down objects to view in the ni...

Страница 15: ...cognition Try exposure times between 1 and 10 seconds depending upon the brightness of the planet to be pho tographed and the ISO of the film being used Piggyback Photography The Moon and planets are interesting targets for the budding astrophotographer but what next Literally thousands of deep sky objects can be captured on film with a type of astrophotography called piggybacking The basic idea i...

Страница 16: ... be necessary If you are unsure or uncomfortable about making optical alignment adjustments we strongly recommend that you just leave it alone Your SkyView Pro 120 EQ comes with a collimating tool Figure 15 shows the collimating tool in place Use of the collimating tool is best done during the day either outdoors or in a well lit room Point the telescope at a dark tar get of uniform brightness lik...

Страница 17: ...ning fluid to a tissue never directly on the optics Wipe the lens gently in a circular motion then remove any excess fluid with a fresh lens tissue Oily fingerprints and smudges may be removed using this method Use caution rubbing too hard may scratch the lens For the objective lens clean only a small area at a time using a fresh lens tissue on each area Never reuse tissues 11 Specifications Objec...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...ay Watsonville CA 95076 If the product is not registered proof of purchase such as a copy of the original invoice is required This warranty does not apply if in Orion s judgment the instrument has been abused mishan dled or modified nor does it apply to normal wear and tear This warranty gives you specific legal rights and you may also have other rights which vary from state to state For further w...

Отзывы: