18

Standby mode 
 

UPS is powered off without output power, 
but the battery still can be charged. 

 

Fault mode 
 

The UPS is in fault mode when no output 
power is supplied from the UPS and the 
fault icon flashes on the LCD display, 
although the information of UPS can be 
displayed in the screen. 

 

3-7. Faults Reference Code 

Fault event 

Fault code  Icon  Fault event 

Fault code  Icon 

Bus start fail 

01 

Inverter voltage Low 

13 

Bus over 

02 

Inverter output short 

14 

 

Bus under 

03 

Battery voltage too high  27 

 

Bus unbalance 

04 

Battery voltage too low 

28 

 

Bus short circuited 

05 

Over temperature 

41 

Inverter soft start fail 

11 

Over load 

43 

 

Inverter voltage high 

12 

 

 

 

 
3-8. Warning indicator 

Warning Icon 

(flashing) 

Alarm 

Low Battery 

 

 

Sounding every second 

Overload 

 

 

Sounding twice every second 

Battery is not connected 

 

 

Sounding every second 

Over Charge 

 

 

Sounding every second 

Site Fault 

 

 

Sounding every second 

EPO enable 

 

 

Sounding every second 

Over temperature 

 

 

Sounding every second 

Charger failure 

 

 

Sounding every second 

Battery fault 

 

 

Sounding every second 

Out of bypass voltage range 

 

 

Sounding every second 

Bypass frequency unstable 

 

 

Sounding every second 

EEPROM error 

 

 

Sounding every second 

 

Содержание DC1000RT

Страница 1: ...Online RT RTX User Manual Online UPS 1K 1 5K 2K 3K...

Страница 2: ...perating principle 4 2 3 Install the UPS 4 2 4 Setup the UPS 6 2 5 Battery Replacement 8 2 6 Battery Kit Assembly option 9 3 Operations 11 3 1 Button operation 11 3 2 LCD Panel 12 3 3 Audible Alarm 13...

Страница 3: ...to UPS output sockets The UPS can be operated by any individuals with no previous experience The UPS can be operated in TN TT power distribution Connect the UPS system only to an earthed shockproof ou...

Страница 4: ...e kept well away from the batteries Caution risk of electric shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals and the ground...

Страница 5: ...2 1 Rear panel view 1K 1 5K 2K NEMA 3K NEMA 1 Programmable outlets connect to non critical loads 2 Output receptacles connect to mission critical loads 3 AC input 4 Input circuit breaker 5 Emergency p...

Страница 6: ...onsideration the UPS is shipped out from factory without connecting battery wires Before install the UPS please follow below steps to re connect battery wires first Step 1 Step 2 Step 3 Remove front p...

Страница 7: ...d external battery Tower Installation Install UPS alone Step 1 Step 2 Step 3 Install UPS and external battery NOTE When installing the UPS or battery pack with feet please keep 70mm distance from the...

Страница 8: ...e also install a UL approved circuit breaker 40A between the mains and AC input in 3K model for safety operation Step 3 UPS output connection There two kinds of outputs programmable outlets and genera...

Страница 9: ...Disable and enable EPO function Keep the pin 1 and pin 2 closed for UPS normal operation To activate EPO function cut the wire between pin 1 and pin 2 Step 7 Turn on the UPS Press the ON Mute button...

Страница 10: ...tes before replacing batteries Note Upon battery disconnection equipment is not protected from power outages Step 1 Step 2 Step 3 Remove front panel Disconnect battery wires Pull out the battery box b...

Страница 11: ...ssembled battery packs on one side of plastic shells Step 4 Cover the other side of plastic shell as below chart Then battery kit is assembly well 3 battery kit Step 1 Remove adhesive tapes Step 2 Con...

Страница 12: ...4 Cover the other side of plastic shell as below chart Then battery kit is assembly well 6 battery kit Step 1 Remove adhesive tapes Step 2 Connect all battery terminals by following below chart Step...

Страница 13: ...his button at least 2 seconds to turn off the UPS in battery mode UPS will be in standby mode under power normal or transfer to bypass mode if the Bypass enable setting by pressing this button Confirm...

Страница 14: ...formation Indicates the output voltage frequency or battery voltage Vac output voltage Vdc battery voltage Hz frequency Load information Indicates the load level by 0 25 26 50 51 75 and 76 100 Indicat...

Страница 15: ...voltage Vdc battery voltage Hz input frequency 3 3 Audible Alarm Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Fault Continuously soundi...

Страница 16: ...ut voltage is 240Vac For 100 110 115 120VAC models you may choose the following output voltage 100 presents output voltage is 100Vac 110 presents output voltage is 110Vac 115 presents output voltage i...

Страница 17: ...is off Interface Setting ENA Bypass mode is enabled when UPS is off DIS Bypass mode is disabled when UPS is off Default 07 Programmable outlets enable disable Interface Setting ENA Programmable outle...

Страница 18: ...table input voltage range is from 160V to 260V 170 270 flashing in turns The acceptable input voltage range is from 170V to 270V For 100 110 115 120 VAC models you may choose the following selection f...

Страница 19: ...imizer When the input voltage is within setting range 3 Vo max UPS will bypass voltage to output for energy saving PFC and INVERTER are off at this mode Frequency Converter mode Rack When input freque...

Страница 20: ...high 27 Bus unbalance 04 x Battery voltage too low 28 Bus short circuited 05 x Over temperature 41 x Inverter soft start fail 11 x Over load 43 Inverter voltage high 12 x 3 8 Warning indicator Warnin...

Страница 21: ...icon and flashing on LCD display and alarm is sounding every second The external or internal battery is incorrectly connected Check if all batteries are connected well Fault code is shown as 27 and th...

Страница 22: ...D display and alarm is continuously sounding A UPS internal fault has occurred There are two possible results 1 The load is still supplied but directly from AC power via bypass 2 The load is no longer...

Страница 23: ...ler Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Storage Temperatur...

Страница 24: ...88 peak 88 typical 90 peak Battery Mode 83 typical 86 peak 85 typical 88 peak BATTERY Battery Type 12V 9Ah 12V 9Ah 12V 9Ah 12V 9Ah Numbers 2 3 4 6 Typical Recharge Time 4 hours recover to 90 capacity...

Страница 25: ...ng telephone number In the United States 1 877 385 1654 Please have the following information ready when you call Model number and Serial number Description of failure or problem Date of failure or pr...

Отзывы: