TGPS-9164GT-M12 Series User
Manual
ORing Industrial Networking Corp
61
Label
Description
Enable Loop Protection
Activate loop protection functions (as a whole)
Transmission Time
The interval between each loop protection PDU sent on each
port. The valid value is 1 to 10 seconds.
Shutdown Time
The period (in seconds) for which a port will be kept disabled
when a loop is detected (shutting down the port). The valid
value is 0 to 604800 seconds (7 days). A value of zero will
keep a port disabled permanently (until the device is
restarted).
Label
Description
Port
Switch port number
Enable
Activate loop protection functions (as a whole)
Action
Configures the action to take when a loop is detected. Valid
values include
Shutdown Port
,
Shutdown Port
, and
Log or
Log Only
.
Tx Mode
Controls whether the port is actively generating loop protection
PDUs or only passively look for looped PDUs.