RGS-9244GP Series User Manual
ORing Industrial Networking Corp.
105
Rate Limiter ID
The rate limiter ID for the settings contained in the same row.
Rate
The rate unit is packet per second (pps), which can be configured as
1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1K, 2K, 4K, 8K, 16K, 32K, 64K,
128K, 256K, 512K, or 1024K.
The 1 kpps is actually 1002.1 pps.
ACL Control List
This page allows you to configure ACE (Access Control Entry).
An ACE consists of several parameters. These parameters vary with the frame type you have
selected. First select the ingress port for the ACE, and then the frame type. Different parameter
options are displayed according to the frame type you have selected.
A frame matching the ACE can be configured here.
Label
Description
Ingress Port
Indicates the ingress port to which the ACE will apply.
Any
: the ACE applies to any port
Port n
: the ACE applies to this port number, where n is the number of the
switch port.
Policy n
: the ACE applies to this policy number, where n can range from 1
to 8.
Frame Type
Indicates the frame type of the ACE. These frame types are mutually
exclusive.
Any
: any frame can match the ACE.
Ethernet Type
: only Ethernet type frames can match the ACE. The IEEE
802.3 descripts the value of length/types should be greater than or equal to
1536 decimal (equal to 0600 hexadecimal).
ARP
: only ARP frames can match the ACE. Notice the ARP frames will not
match the ACE with Ethernet type.