IPS-2042 Seris User’s Manual
ORing Industrial Networking Corp.
41
Disabled
AC Disconnect
Mark the blank to enable “
AC Disconnect
” function.
Capacitive Detection
Mark the blank to enable “
Capacitive Detection
” function
5.1.8.2 Port
Setting
The following interface is the PoE setting interface. There are 4 ports (port 1 to port 4) act
as PSE (Power Supply Equipment) ports.
Label
Description
Port
Port number.
Enable state
Mark the blank to enable P.O.E. function for specific ports
Power Limit From
Classification
Set the “
Power Limit From Classification
” function for each
P.O.E. ports
Legacy
The legacy detection is to identify the PD devices that did not
follow the IEEE 802.3af standard their unique electrical signatures
in order for the PoE switch can provide the power to those PD
devices
Priority
Set port priority for the P.O.E. power management. 1 = C (critical),
2 = H (High), 3 = L (Low)
Power Limit
Set the power limit value. The maximum value must less 15400