background image

IES-2050 User’s Manual 

ORing Industrial Networking Corp. 

33 

 

LLDP interface 

 

The following table describes the labels in this screen. 

Label 

Description 

LLDP Protocol 

Enable

” or “

Disable

” LLDP function. 

LLDP Interval 

The interval of resend LLDP (by default at 30 seconds) 

Apply 

Click “

Apply

” to activate the configurations. 

Help 

Show help file. 

 

 

Содержание IES-2050

Страница 1: ... User s Manual Version 1 0 May 2008 ORing Industrial Networking Corp 4F NO 3 Lane235 Baociao Rd Sindian City Taipei County 23145 Taiwan R O C Tel 886 2 2918 3036 Fax 886 2 2918 3084 Website www oring networking com E mail support oring networking com ...

Страница 2: ...ont Panel LEDs 7 3 3 Bottom Panel 7 3 4 Rear Panel 8 Cables 9 4 1 Ethernet Cables 9 4 1 1 100BASE TX 10BASE T Pin Assignments 9 WEB Management 11 5 1 Configuration by Web Browser 11 5 1 1 About Web based Management 11 5 1 2 Basic Setting 13 5 1 2 1 Switch setting 13 5 1 2 2 Admin Password 13 5 1 2 3 IP configuration 14 5 1 2 4 SNTP Configuration 15 5 1 2 5 Backup Restore 18 5 1 2 6 Upgrade Firmwar...

Страница 3: ...Ring 21 5 1 4 3 RSTP 23 5 1 5 SNMP Configuration 25 5 1 5 1 SNMP Agent Setting 25 5 1 5 2 SNMP Trap Setting 26 5 1 6 VLAN 27 5 1 6 1 VLAN Configuration Port Based 27 5 1 7 Warning 28 5 1 7 1 Fault Alarm 28 5 1 8 Front Panel 31 5 1 9 Save Configuration 32 5 1 10 LLDP 32 Technical Specifications 34 ...

Страница 4: ...on is powerful network management software With its friendly and powerful interface you can easily configure multiple switches at the same time and monitor switches status 1 2 Software Features World s fastest Redundant Ethernet Ring Recovery time 10ms over 250 units connection Supports Ring Coupling Dual Homing and RSTP over O Ring Support fast recovery mode Easy to configure Web Windows utility ...

Страница 5: ...N Rail Each IES 2050 switch has a DIN Rail kit on rear panel The DIN Rail kit helps switch to fix on the DIN Rail It is easy to install the switch on the DIN Rail Step 1 Slant the switch and mount the metal spring to DIN Rail Step 2 Push the switch toward the DIN Rail until you heard a click sound Metal Spring ...

Страница 6: ... the wall Each IES 2050 switch has another installation method for users to fix the switch on the wall by the wall mount planet The following steps show how to mount the switch on the wall Step 1 Remove DIN Rail kit Step 2 Use 4 screws to mount the switch on the wall Wall mount planet ...

Страница 7: ...at stick on the IES 2050 Port Description 10 100 RJ 45 fast Ethernet ports 10 100Base T X RJ 45 fast Ethernet ports support auto negotiation Default Setting Speed auto Duplex auto Flow control disable Reset Push reset button 2 to 3 seconds to reset the switch Push reset button 5 second to reset the switch into Factory Default IES 2050 ...

Страница 8: ...eans that the switch is the ring master of O Ring 6 DC 9 30V power input 3 2 Front Panel LEDs LED Color Status Description PWR Green On DC power activated R M Green On O Ring Master Ring Amber On O Ring enabled 10 100Base T X Fast Ethernet ports On Port link up LNK ACT Green Blinking Data transmitted 3 3 Bottom Panel The bottom panel components of IES 2050 are showed as below 1 Terminal block incl...

Страница 9: ...IES 2050 User s Manual ORing Industrial Networking Corp 8 3 4 Rear Panel The rear panel components of IES 2050 are showed as below 1 Screw holes for wall mount kit 2 Din Rail kit 1 1 2 ...

Страница 10: ...Length Connector 10BASE T Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ 45 100BASE TX Cat 5 100 ohm UTP UTP 100 m 328 ft RJ 45 4 1 1 100BASE TX 10BASE T Pin Assignments With 100BASE TX 10BASE T cable pins 1 and 2 are used for transmitting data and pins 3 and 6 are used for receiving data RJ 45 Pin Assignments Pin Number Assignment 1 TD 2 TD 3 RD 4 Not used 5 Not used 6 RD 7 Not used 8 Not used The IES 205...

Страница 11: ...in Number MDI port MDI X port 1 TD transmit RD receive 2 TD transmit RD receive 3 RD receive TD transmit 4 Not used Not used 5 Not used Not used 6 RD receive TD transmit 7 Not used Not used 8 Not used Not used Note and signs represent the polarity of the wires that make up each wire pair ...

Страница 12: ...aim to reduce network bandwidth consumption enhance access speed and present an easy viewing screen Note By default IE5 0 or later version does not allow Java Applets to open sockets You need to explicitly modify the browser setting in order to enable Java Applets to use network ports Preparing for Web Management The default value is as below IP Address 192 168 10 1 Subnet Mask 255 255 255 0 Defau...

Страница 13: ...IES 2050 User s Manual ORing Industrial Networking Corp 12 Login screen Main Interface Main interface ...

Страница 14: ...ription Display the description of switch System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the name of contact person or organization Firmware Version Display the switch s firmware version Kernel Version Display the kernel software version MAC Address Display the unique hardware address assigned by manufacturer default 5 1 2 2 Admin Password C...

Страница 15: ...ssword Key in the new password The default is admin Confirm password Re type the new password Apply Click Apply to activate the configurations 5 1 2 3 IP configuration You can configure the IP Settings and DHCP client function through IP configuration IP Configuration interface The following table describes the labels in this screen Label Description DHCP Client To enable or disable the DHCP clien...

Страница 16: ...nction is enabling you do not need to assign the IP address The network DHCP server will assign the IP address for the switch and it will be displayed in this column The default IP is 192 168 10 1 Subnet Mask Assign the subnet mask for the IP address If DHCP client function is enabling you do not need to assign the subnet mask Gateway Assign the network gateway for the switch The default gateway i...

Страница 17: ... time zone The following table lists the different location time zone for your reference Local Time Zone Conversion from UTC Time at 12 00 UTC November Time Zone 1 hour 11 am Oscar Time Zone 2 hours 10 am ADT Atlantic Daylight 3 hours 9 am AST Atlantic Standard EDT Eastern Daylight 4 hours 8 am EST Eastern Standard CDT Central Daylight 5 hours 7 am CST Central Standard MDT Mountain Daylight 6 hour...

Страница 18: ... 8 hours 8 pm JST Japan Standard USSR Zone 8 9 hours 9 pm EAST East Australian Standard GST Guam Standard USSR Zone 9 10 hours 10 pm IDLE International Date Line NZST New Zealand Standard NZT New Zealand 12 hours Midnight The following table describes the labels in this screen Label Description SNTP Sever IP Address Set the SNTP server IP address Daylight Saving Period Set up the Daylight Saving b...

Страница 19: ...his screen Label Description TFTP Server IP Address Fill in the TFTP server IP Restore File Name Fill the file name Restore Click restore to restore the configurations Restore File Name Fill the file name Restore Click restore to restore the configurations Backup Click backup to backup the configurations 5 1 2 6 Upgrade Firmware Upgrade Firmware allows you to update the switch firmware Before upda...

Страница 20: ...on Click Reset to reset all configurations to the default value You can select Keep current IP address setting and Keep current username password to prevent IP and username password from default 5 1 2 8 System Reboot System Reboot interface 5 1 3 Port Configuration 5 1 3 1 Port Control By this function you can set the state speed duplex flow control and security of the ...

Страница 21: ...number for setting State Enable Disable the port Speed Duplex You can set Auto negotiation 100 full 100 half 10 full 10 half mode Flow Control Support symmetric and asymmetric mode to avoid packet loss when congestion occurred Apply Click Apply to activate the configurations 5 1 3 2 Port Status The following information provides the current port status Port Status interface ...

Страница 22: ...ce The following table describes the labels in this screen Label Description Active Activate the fast recovery mode port Port can be configured as 5 priorities Only the port with highest priority will be the active port 1st Priority is the highest Apply Click Apply to activate the configurations 5 1 4 2 O Ring O Ring is one of the most powerful Redundant Ring technology in the world The recovery t...

Страница 23: ...this switch is Ring Master 2 nd Ring Port The backup port when this switch is Ring Master Coupling Ring Mark to enable Coupling Ring Coupling Ring can be used to divide a big ring into two smaller rings to avoid effecting all switches when network topology change It is a good application for connecting two O Rings Coupling Port Link to Coupling Port of the switch in another ring Coupling Ring need...

Страница 24: ...Apply to activate the configurations Note We don t suggest you to set one switch as a Ring Master and a Coupling Ring at the same time due to heavy load 5 1 4 3 RSTP The Rapid Spanning Tree Protocol RSTP is an evolution of the Spanning Tree Protocol It provides faster spanning tree convergence after a topology change The system also supports STP and the system will auto detect the connected device...

Страница 25: ... from its Rapid Spanning Tree Protocol learning and listening states to the forwarding state Enter a value between 4 through 30 Path Cost 1 200000000 The cost of the path to the other bridge from this transmitting bridge at the specified port Enter a number 1 through 200000000 Priority 0 240 Decide which port should be blocked by priority in LAN Enter a number 0 through 240 The value of priority m...

Страница 26: ...gorithm result at this table RSTP Information interface 5 1 5 SNMP Configuration Simple Network Management Protocol SNMP is the protocol developed to manage nodes servers workstations routers switches and hubs etc on an IP network SNMP enables network administrators to manage network performance find and solve network problems and plan for network growth Network management systems learn of problem...

Страница 27: ...ported Each Community String is maximum 32 characters Keep empty to remove this Community string 5 1 5 2 SNMP Trap Setting A trap manager is a management station that receives traps the system alerts generated by the switch If no trap manager is defined no traps will issue Create a trap manager by entering the IP address of the station and a community string To define management stations as trap m...

Страница 28: ...network traffic Only the members of the VLAN will receive traffic from the same members of VLAN Basically creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch However all the network devices are still plugged into the same switch physically The switch supports port based VLAN only 5 1 6 1 VLAN Configuration Port Based Packets ca...

Страница 29: ...anel 5 1 7 1 Fault Alarm System Warning SYSLOG Setting The SYSLOG is a protocol to transmit event notification messages across networks Please refer to RFC 3164 The BSD SYSLOG Protocol System Warning SYSLOG Setting interface The following table describes the labels in this screen Label Description SYSLOG Mode Disable disable SYSLOG Client Only log to local system Server Only log to a remote SYSLOG...

Страница 30: ... screen Label Description Page Select LOG page Reload To get the newest event logs and refresh this page Clear Clear log Help Show help file System Warning SMTP Setting The SMTP is Short for Simple Mail Transfer Protocol It is a protocol for e mail transmission across the Internet Please refer to RFC 821 Simple Mail Transfer Protocol ...

Страница 31: ...n Username the authentication username Password the authentication password Confirm Password re enter password Recipient E mail Address The recipient s E mail address It supports up to 6 recipients per mail Apply Click Apply to activate the configurations Help Show help file System Warning Event Selection SYSLOG and SMTP are the two warning methods that supported by the system Check the correspond...

Страница 32: ...in this screen Label Description System Event System Cold Start Alert when system restart O Ring Topology Change Alert when O Ring topology change Port Event Disable Link Up Link Down Link Up Link Down Apply Click Apply to activate the configurations Help Show help file 5 1 8 Front Panel Show IES 2050 panel Click Close to close panel on web ...

Страница 33: ...nent flash memory Otherwise the current configuration will be lost when power off or system reset System Configuration interface The following table describes the labels in this screen Label Description Save Save all configurations Help Show help file 5 1 10 LLDP LLDP Link Layer Discovery Protocol function allows the switch to advertise its information to other nodes on the network and store the i...

Страница 34: ...interface The following table describes the labels in this screen Label Description LLDP Protocol Enable or Disable LLDP function LLDP Interval The interval of resend LLDP by default at 30 seconds Apply Click Apply to activate the configurations Help Show help file ...

Страница 35: ...rocessing Store and Forward Firmware upgrade TFTP Ring redundancy RSTP O Ring Couple Ring Dual Homing Fast recovery Interface RJ45 Ports 10 100Base T X Auto MDI MDI X LED Indicators Power Power indicator Green RJ45 Ports Link Activity Green Blinking Green R M Ring master Amber Ring Ring port Amber Power Requirements Power Input Voltage PWR1 9 36V DC in 3 pin Terminal block Reverse Polarity Protect...

Страница 36: ... 102mm D x 24mm H Casing IP 30 protection Regulatory Approvals Regulatory Approvals FCC Part 15 CISPER EN55022 class A EMS EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 CS Shock IEC 60068 2 27 Free Fall IEC 60068 2 32 Vibration IEC 60068 2 6 Warranty 5 years ...