DIP Switch Setting

Wiring

The switch  supports  dual  redundant  power  supplies,  Power  Supply1
(PWR1) and  Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.

STEP 1:

Insert  the  negative/positive  wires  into  the  V-/V+ terminals,

respectively.

STEP 2:

To  keep  the  DC  wires  from  pulling  loose,  use  a  small  flat-

blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.

PWR-1

PWR-2 1A@24V

V2- V2+                 V1- V1+

Power inputs

The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an close circuit when a
user-configured event is triggered. If a user-configured event does not occur, the fault
circuit remains opened.

Relay contact

Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.

Grounding

Configurations

After installing the switch, the green power LED should turn on. Please refer
to the following tablet for LED indication.

Specifications

LED

Color

Status

Description

P1

Green

On

DC power 1 activated

P2

Green

On

DC power 2 activated

Fault

Amber

On

Power failure

10/100Base-T(X) Ethernet ports

LNK/ACT

Green

On

Port is linked

Duplex

Amber

On

Port link up for full duplex

Off

Port link up for half duplex

For pin assignments for different types of cables, please refer to the following
tables.

ORing Industrial Networking Corp.

Copyright©  2010 ORing

All rights reserved.

TEL: +886-2-2218-1066
FAX: +886-2-2218-1014

Website: www.oringnet.com
E-mail: [email protected]

Version 2.1

DIP-2

OFF

OFF

ON

DIP-1

Power failure relay alarm disabled

PWR-1 failure, relay alarm enabled

PWR-2 failure, relay alarm enabled

OFF

ON

OFF

Description

ON

PWR-1 or PWR-2 failure,
relay alarm enabled

ON

10/100Base-T(X) RJ-45

Pin Number

Assignment

1

TD+

2

TD-

3

RD+

4

Not used

5

Not used

6

RD-

7

Not used

8

Not used

Note:

“+” and “-” signs represent the polarity of the wires

that make up each wire pair

.

ORing Switch Model

Physical Ports

Technology

Ethernet Standards

LED Indicators

Green: Power LED x2

Power indicator

10/100Base-T(X) Port in RJ45

Auto MDI/MDIX

IEEE 802.3 for 10Base-T,

IEEE 802.3u for 100Base-TX

IEEE 802.3x for Flow control

Processing

Store-and-Forward

Environmental

-40 to 85 C (-40 to 185 F)

o

o

Storage Temperature

Operating Temperature

5% to 95% Non-condensing

Operating Humidity

Regulatory approvals

CE EMC (EN 55024, EN 55032), FCC Part 15 B

EMC

EN 55024 (IEC/EN 61000-4-2 (ESD: Contact 4KV, Air 8KV), IEC/EN 61000-4-3 (RS: 3V)

IEC/EN 61000-4-4 (EFT Power 0.5KV, Signal 0.5KV),

IEC/EN 61000-4-5 (Surge: Power 0.5KV, Signal 1KV), IEC/EN 61000-4-6 (CS: 3V),

IEC/EN 61000-4-8(PFMF), IEC/EN 61000-4-11 (DIP))

EMS

IEC60068-2-27

Shock

IEC60068-2-32

IEC60068-2-6

Vibration

Free Fall

MTBF

2,439,118hrs

-40 to 75 C (-40 to 167 F)

o

o

Amber: Indicate PWR1 or PWR2 failure

Fault indicator

Fault contact

Relay

Relay output to carry capacity of 1A at 24 VDC

Power

Redundant Input power

Power consumption(Typ.)

<3.7Watts, 0.23A-0.07A

Overload current protection

Reverse polarity protection

Present

Present

Physical Characteristic

Enclosure

IP-30 Metal

Dimension (W x D x H)

Weight (g)

391 g

Dual 12~48VDC on 6-pin terminal block

26.1(W)x94.9(D)x144.3(H) mm (1.03x3.74x5.68inch.)

10/100Base-T(X) RJ45 Port

Indicator

Upper LED for Link/Act indicator: Green for Link/Act

Lower LED for duplex indicator, Amber for full duplex, off for half duplex

EN60950-1(LVD)

Safety

IES-1080A

8

MAC Table

1K

Packet buffer

448 Bits

Warranty

5 years

Switch Properties

Switching latency: 7 us

Switching bandwidth: 1.6Gbps

Throughput (packet per second): 1.19Mpps@64Bytes packet

Hardware Version

V2.0

EN 55032, CISPR32, EN 61000-3-2, EN 61000-3-3, FCC Part 15 B class A

EMI

Industrial Unmanaged Switch

SWITCH

I N D U S T R I A L

IES-1080A

IES-1080A