IDS-5012 Series
User’s Manual
51
ORing Industrial Networking Corp.
The following table describes the labels in this screen.
Label
Description
Data Encryption
Use SSL to encrypt data.
Telnet Negotiation
Full Telnet command / symbol compatible
TCP Server Port
Set the port number for data transmission.
Idle Timeout
When serial port stops data transmission for a defined period of time (Idle Timeout), the
connection will be closed and the port will be freed and try to connect with other hosts.
0 indicate disable this function. Factory default value is 0. If Multilink is configured,
only the first host connection is effective for this setting.
Alive Check
The serial device will send TCP alive-check package in each defined time interval (Alive
Check) to remote host to check the TCP connection. If the TCP connection is not
alive, the connection will be closed and the port will be freed. 0 indicate disable this
function. Factory default is 0.
Max Connection
The number of Max connection can support simultaneous connections are 5, default
values is 1.
Table 5-20 TCP server mode
Service Mode
– TCP Client Mode
In TCP Client Mode, device can establish a TCP connection with server by the
method you set (Startup or any character). After the data has been
transferred, device can disconnect automatically from the server by using the
TCP alive check time or Idle timeout settings.