In TCP Server Mode, DS is configured with a unique Port combination on a
TCP/IP network. In this case, DS waits passively to be contacted by the
device. After the device establishes a connection with the serial device, it
can then proceed with data transmission. TCP Server mode also
supports up to 5 simultaneous connections, so that multiple device can
receive data from the same serial device at the same time.
Label
Description
Data Encryption
Use SSL to encrypt data.
Telnet
Negotiation
Full Telnet command / symbol compatible
TCP Server Port
Set the port number for data transmission.
Idle Timeout
When serial port stops data transmission for a defined period of time (Idle
Timeout), the connection will be closed and the port will be freed and try to
connect with other hosts. 0 indicate disable this function. Factory default
value is 0. If Multilink is configured, only the first host connection is effective for
this setting.
Alive Check
The serial device will send TCP alive-check package in each defined time
interval (Alive Check) to remote host to check the TCP connection. If the TCP
connection is not alive, the connection will be closed and the port will be freed.
0 indicate disable this function. Factory default is 0.
Max Connection
The number of Max connection can support simultaneous connections are 5,
default values is 1.
6. Service Mode – TCP Client Mode
In TCP Client Mode, device can establish a TCP connection with