IMG-1312-D User’s Manual
3. Port Profile
Label
Description
Serial to Ethernet
Flush Data Buffer After:
The received data will be queued in the buffer until all the delimiters are
matched. When the buffer is full (4K Bytes) or after "
flush S2E data buffer
"
timeout, the data will also be sent. You can set the time from 0 to 65535
seconds.
Delimiter:
You can define max. 4 delimiters (00~FF, Hex) for each way. The data will be
hold until the delimiters are received or the option “
Flush Serial to Ethernet
data buffer
” times out. 0 means disable. Factory default is 0
Ethernet to serial
Flush Data Buffer After:
The received data will be queued in the buffer until all the delimiters are
matched. When the buffer is full (4K Bytes) or after "
flush E2S data buffer
"
timeout, the data will also be sent. You can set the time from 0 to 65535
seconds.
Delimiter:
You can define max. 4 delimiters (00~FF, Hex) for each way. The data will be
hold until the delimiters are received or the option “
Flush Ethernet to Serial
data buffer
” times out. 0 means disable. Factory default is 0