(9).Abnormity and Solution
Fault
Cause
Solution
Light on, but motor
does not work
The leaf blocked
Get rid of the blocking
The capacitor damaged
Replace capacitor
The motor jammed bearing
damaged
Replace motor
The internal with of motor off or
a bad smell from the motor
Replace motor
Light does not work,
motor does not work
Beside the above mentioned, check the following:
Light damaged
Replace lights
Power cord looses
Connect the wires as per
the electric diagram
Oil leakage
One way valve and the air
ventilation entrance are not
tightly sealed
Take down the one way
valve and seal with glue
Leakage from the connection
of U-shaped section and
cover
Take U-shaped section
down and seal with soap
or paint
Shake of the body
The leaf damaged and causes
shaking
Replace the leaf
The motor is not tightly
hanged
Lock the motor tightly
The body is not tightly
hanged
Fixed the body tightly
Insufficient suction
The distance between the
body and the gas top too long
Readjust the distance
Too much ventilation from
open doors or windows
Choose a new place and
resemble the machine
The machine inclines The fixing screw not tight
enough
Tighten the hanging
screw and make it
horizontal
The hanging screw not tight
enough
Tighten the hanging
screw and make it
horizontal
37
Содержание ORC-1003-C
Страница 1: ......
Страница 7: ......
Страница 15: ......
Страница 16: ...15 ...
Страница 17: ......
Страница 31: ... 4 Air education setting Product one 30 ...
Страница 36: ...Touch control switch No one Touch control switch No two Touch control switch No three 35 ...
Страница 40: ...Exhaustor Manual de Instrucciones 39 ...
Страница 62: ...HOTTE ASPIRANTE Mode d emploi 61 ...