LPG
Natural Gas Natural Gas
G 30
G 20
G 25
OUTER DEPTH
Injector
mm
0.85
1,35
1,35
OUTER HEIGHT
Gas Flow
m3/h
0,082
0,289
0,315
SUPPLY VOLTAGE
Power
KW
2,600
2,700
2,540
Red'd flam
KW
0,700
0,715
0,69
Injector
mm
0.65
0,92
0.92
Gas Flow
m3/h
0,046
0,143
0,166
Power
KW
1,500
1,330
1,350
Red'd flam
KW
0,500
0,385
0,360
Injector
mm
0.50
0,70
0,70
Gas Flow
m3/h
0,028
0,080
0,088
Power
KW
0.900
0,760
0,715
Red'd flam
KW
0,320
0,300
0,300
Before making the connections of the appliance
Before starting to use the appliance, read the user manual of the
appliance carefully. In this user Manual, there are important information
regarding your, our customers security, how you will use it and how you
will make its maintenance.
Keep this user manual in good shape, by taking into consideration that
the appliance shall be used by others.
Note :
This user manual is prepared for more than one model.
Some of the features specified in the Manual may not be
available in your appliance.
Big Burner
Med. Burner
Small Burner
4
3 - TECHNICAL FEATURES OF YOUR COOKER
OUTER WIDTH
BURNER INJECTOR VALUES
ACCORDING TO THE GAS TYPE
Big Burner
230 V , 50 Hz
580 mm
HOT PLATE 145 mm
85 mm
510 mm
900 W
Medium Burner
Red'd Flame Gas Cock Adjustment:
To adjust your oven acc. to the gas type, make the adjust. for reduced
flame carefully by turning with a small scredriver as shown below on the
scr.in the mid. of the gas cocks as well as nozzle changes.
2 turns anticlockwise
Small Burner
SPECIFICATIONS
2 turns clockwise
3 turns anticlockwise
3 turns clocwise
2,5 turns clockwise
2,5 turns anticlockwi
G30
G20,G25
G20,G25
G30
From LPG to Nat.gas
from Nat.gas to LPG