4
•
Unauthorized reproduction or copying of all or part of this manual is prohibited.
•
Oriental Motor shall not be liable whatsoever for any problems relating to
industrial property rights arising from use of any information, circuit, equipment
or device provided or referenced in this manual.
•
Characteristics, specifications and dimensions are subject to change without
notice.
•
While we make every effort to offer accurate information in the manual, we
welcome your input. Should you find unclear descriptions, errors or omissions,
please contact the nearest office.
•
is a registered trademark or trademark of Oriental Motor Co., Ltd.,
in Japan and other countries.
© Copyright ORIENTAL MOTOR CO., LTD. 2016
Published in January 2021
Technical Support Tel:800-468-3982
8:30am EST to 5:00pm PST
(
M-F
)
www.orientalmotor.com
Schiessstraße 44, 40549 Düsseldorf, Germany
Technical Support Tel:00 800/22 55 66 22
www.orientalmotor.de
Tel:+44-1256347090
www.oriental-motor.co.uk
Tel:+33-1 47 86 97 50
www.orientalmotor.fr
Tel:+39-02-93906347
www.orientalmotor.it
• Please contact your nearest Oriental Motor office for further information.
4-8-1Higashiueno,Taito-ku,Tokyo 110-8536
Japan
Tel:+81-3-6744-0361
www.orientalmotor.co.jp
Tel:0800-060708
www.orientalmotor.com.tw
Singapore
Tel:1800-842-0280
www.orientalmotor.com.sg
Tel:1800-806-161
www.orientalmotor.com.my
Korea
Tel:080-777-2042
www.inaom.co.kr
Tel:1800-888-881
www.orientalmotor.co.th
Tel:400-820-6516
www.orientalmotor.com.cn
Tel:1800-120-1995 (For English)
1800-121-4149 (For Hindi)
www.orientalmotor.co.in
Grounding
Connect the Protective Earth Terminal
on the
motor to the ground near the motor.
Minimize the wiring length of the ground cable.
Protective
Earth
Terminal
Grounding
Note
Be sure to ground the motor and driver. Failure to do so may result in
electric shock or damage to the product.
Static electricity may cause damage to the product if the protective
earth terminals are not grounded.
■
■
Ground terminal
•
Applicable crimp terminal:
Round crimp terminal with insulation cover
•
Thread size of terminal: M4
•
Tightening torque: 1.2 N·m (10.6 lb-in)
•
Applicable lead wire:
AWG18 to 14 (0.75 to 2.0 mm
2
)
[mm (in.)]
4.8 (0.19) or less
9.5 (0.37) or less
Ø4.1 (0.16) or more
■
■
Precautions about static electricity
Static electricity may cause the driver to malfunction or suffer damaged.
Be sure to ground the motor and driver to prevent them from being damaged by
static electricity.
Inspection
It is recommended that periodic inspections for the items listed below are conducted
after each operation of the motor.
If an abnormal condition is noted, discontinue any use and contact your nearest
Oriental Motor sales office.
Note
Do not conduct the insulation resistance measurement or dielectric
strength test with the motor and driver connected. Conducting the
insulation resistance measurement or dielectric strength test with the
motor and driver connected may result in damage to the product.
■
■
During inspection
•
Are any of the mounting screws of the motor and gearhead loose?
•
Are there any abnormal noises from inside of the motor or gearhead?
•
Is there any misalignment between the load shaft and the motor output shaft or
the gearhead output shaft?
•
Are there any scratches, signs of stress or loose driver connections in the cable?
Regulations and standards
■
■
Standard and CE Marking
This product is recognized by UL under the UL and CSA standards, and it is also
affixed the CE Marking under the Low Voltage Directive.
The motor model name represents the model that conforms to the standards.
z
UL Standards and CSA Standards
Applicable Standards
Applicable Standards
Certification Body
Standards File No.
UL 1004-1
CSA C22.2 No.100
UL
E335369
∗
Thermal class UL/CSA Standards: 105(A)
z
Low Voltage Directive
•
This product is designed and manufactured to be incorporated in equipment.
•
This product cannot be used in IT power distribution systems.
•
Install the product within the enclosure in order to avoid contact with hands.
•
Ground the Protective Earth Terminals for the motor and driver securely.
•
Isolate the motor cable, power-supply cable and other drive cables from the signal
cables by means of double insulation.
Applicable Standards
EN 60034-1, EN 60034-5, EN 60664-1
Installation conditions (EN Standard)
•
For incorporating in equipment
•
Overvoltage category:
Ⅱ
•
Pollution degree: 2
•
Protection against electric shock: Class
Ⅰ
∗
Thermal class EN Standards: 120(E)
z
The motor temperature rise tests
A temperature test has been conducted with a heatsink plate.
The size, thickness and material of the heatsink plates are as table.
[mm (in.)]
Motor model
Size
Thickness
Material
BLM230
115×115 (4.53×4.53)
5 (0.20)
Aluminum
alloy
BLM260
,
BLM460S
135×135 (5.31×5.31)
BLM5120
165×165 (6.50×6.50)
BLM5200
,
BLM6200S
200×200 (7.87×7.87)
BLM5300
,
BLM5400
BLM6300S
,
BLM6400S
250×250 (9.84×9.84)
6 (0.24)
■
■
RoHS Directive
The products do not contain the substances exceeding the restriction values of RoHS
Directive (2011/65/EU).
General specifications
Operation
environment
Ambient
temperature 0 to +40 °C [+32 to +104 °F] (non-freezing)
Ambient
Humidity
85% or less (non-condensing)
Altitude
Up to 1000 m (3300 ft.) above sea level
Surrounding
atmosphere
No corrosive gas, dust, water or oil.
Cannot be used in radioactive materials, magnetic field,
vacuum or other special environment.
Details about the installation location are described on p.2.
Vibration
Not subject to continuous vibrations or excessive impact. In
conformance with JIS C 60068-2-6 "Sine-wave vibration test
method"
Frequency range: 10 to 55 Hz
Pulsating amplitude: 0.15 mm (0.006 in.)
Sweep direction: 3 directions (X, Y, Z)
Number of sweeps: 20 times
Storage
environment
Shipping
environment
Ambient
temperature −20 to +70 °C [−4 to +158 °F] (non-freezing)
Ambient
Humidity
85% or less (non-condensing)
Altitude
Up to 3000 m (10000 ft.) above sea level
Surrounding
atmosphere
No corrosive gas, dust, water or oil.
Cannot be used in radioactive materials, magnetic field,
vacuum or other special environment.
Degree of protection
IP40