DO NOT INSTALL CO ALARMS 

Improper location can affect the sensitive electronic components in this alarm. To avoid causing damage to the unit,. to provide 

optimum performance, and to prevent unnecessary nuisance alarms: 

1.

 

The alarm is not be located within 1.5m (5 feet) of any cooking appliance.   

2.

 

Situations where the temperature may fall below   

5℃

  or rise above 38

3.

 

In a damp or humid area such as near bathrooms or in shower areas. 

4.

 

Any area where high levels of dusty, dirty or greasy emissions could contaminate or clog the sensor.   

5.

 

Behind drapes or furniture.   

6.

 

In the path o fair discharged from a furnace/air conditioning vent or ceiling fan.   

7.

 

Outside the building.   

8.

 

Directly above a sink or cooker.   

 

WARNING:

 

This CO alarm is designed for indoor use only. Do not expose to rain or moisture It will not 

protect against the risk of CO poisoning when the battery has drained. 

 

DO NOT open or tamper with the alarm as this could cause malfunction.   

 

HOW TO INSTALL THIS CARBON MONOXIDE ALARM 

   

 

This CO alarm can be installed either on the ceiling or the wall using the fixings provided.   

 

 

 

 

 

 

 

 

 

 

DANGER:  

ELECTRICAL SHOCK HAZARD.

 

Turn off power at the main fuse box or circuit

 

breaker by removing the fuse or

 

switching the circuit breaker to the

 

OFF 

position.

 

WARNING:

 

This CO alarm is mains powered and requires wiring by a qualified electrician in accordance with 

the current Regulations for Electrical Installations. The circuit used to power the CO alarm must be a 

dedicated permanent supply that cannot be switched off accidentally by the normal user. Before installing 

ensure the electrical supply is isolated. 

1.

 

From back of CO alarm, remove the mounting plate by turning it counterclockwise.   

(To later engage tamper-resist feature, twist out and set aside one of the pins molded into plate. Both pins are exactly the 

same.)  

2.

 

Gently pull household wires through center hole of plate. 

3.

 

Secure plate to ceiling or wall with mounting screws.   

4.

 

With a small wire connector, connect brown wire from connecter plug to brown household 

wire. 

5.

 

Connect blue wire from connector plug to blue household wire. 

Содержание VST-C598IH

Страница 1: ...ectrochemical Power Source 220 240V AC 50Hz and 9V DC Battery back up Operation Current 60mA operation mains Alarm Level 50ppm Between 60 90 min 100ppm Between 10 40 min 300ppm 3min Alarm Sound Level...

Страница 2: ...uations z Extended operation of unvented fuel burning devices range oven fireplace etc z Temperature inversions which can trap exhaust gases near the ground z Vehicle idling in an open or closed garag...

Страница 3: ...Ignore a safety device when it shuts an appliance z Ignore any warning from your CO alarm CO ALARM PLACEMENT Typical single story home For minimum protection you should fit an alarm in the bedrooms or...

Страница 4: ...tion HOW TO INSTALL THIS CARBON MONOXIDE ALARM This CO alarm can be installed either on the ceiling or the wall using the fixings provided DANGER ELECTRICAL SHOCK HAZARD Turn off power at the main fus...

Страница 5: ...Push test button to test CO alarm See TESTING THE CO ALARM INTERCONNECTING SMOKE ALARMS For interconnecting line only use 14 18 AWG minimum solid or stranded wire When being interconnected maximum wi...

Страница 6: ...minutes NOTE After initial 4 minute Silence cycle the CO Alarm re evaluates present CO levels and responds accordingly If CO levels remain potentially dangerous or start rising higher the alarm will s...

Страница 7: ...ting step away when horn starts sounding Push and hold the Test Hush button on the cover until the LED flashes The alarm horn will sound 4 beeps a pause then 4 beeps The ALARM RED light will flash The...

Страница 8: ...battery to make the alarm work long Some batteries can be used more than one year The battery should only be replaced by a qualified electrician or similarly qualified person 1 Turn off AC power suppl...

Страница 9: ...r using aerosols or adhesives WARNING Reinstall the CO Alarm as soon as possible to assure continuous protection The following is a list of substances that at high levels can damage the sensor or caus...

Страница 10: ...ventilating your home CO Alarm sounds frequently even though no high levels of CO are revealed in an investigation The CO Alarm may be improperly located Refer to CO ALARM PLACEMENT Relocate your ala...

Отзывы: