Thank you for purchasing ORIENTAL MOTOR products. 

Please read this operating manual thoroughly  before

installing and operating the fan, and always keep the 

manual  where it is readily accessible.

1. Precautions

1.1 Precautions for Installation

Do not use in a place where there is flammable gas and/or corrosive gas.

Fans for use only in equipment of protection class 

.

Lüfter zur Verwendung in Geräten der Schutzklasse 

Connect the ground wire to the ground terminal inside the terminal box. 
Das Erdungskabel wird an dem als Erde gekennzeichneten Pol im Anschlu

β

kasten angeklemmt.   

When installing the fan into your equipment, ensure that the motor lead wires are fixed and do not move.

In addition, do not apply any pressure to these lead wires.

Installation must be performed by a qualified installer.

1.2   Precautions for Operation

Always turn off power to thermally protected fan before conducting checks or performing work on the fan.

These types of fans will restart automatically when fan temperature falls below a certain level.

The enclosure temperature of this fan can exceed 70

(depending on operation conditions).

In case fan is accessible during operation, please attach the following warning label so that it is clearly visible.     Warning label          

Do not touch the fan blades when the fan is in operation.  

The use of the optional fingerguard is recommended to ensure  protection.
Wegen der Verletzungsgefahr dürfen die Lüfterflügel bei Ventilatorbetrieb nicht berührt werden.
Der Gebrauch des als Sonderzubehör erhältlichen Fingerschutzes ist empfehlenswert, um erhöhte Sicherheit zu gewährleisten.  

<Table of Contents>

1. Precautions

...........................................

Page 1

4. Installation ...........................................Page 2

2. Checking the Package Contents

...........

Page 1

5. Noise Protection..................................Page 4

3. Connection

............................................

Page 2

6. Overheat Protection ............................Page 4

2. Checking the Package Contents

2.1  Checking the contents

Please make sure that the package contains all of the items listed below.

Contact your nearest ORIENTAL MOTOR office if any of these items are not included or are defective.

Fan

............................................................................................

1 piece

Variable resistor (with adjustment knob and dial plate).............1 set

Operating manual (this manual)

................................................

1 piece

2.2  Checking the model name

This manual covers the products specified below.

Please make sure that the model, voltage, current as you ordered by the nameplate.

MRS18V2-B, MRS18V2-D

Fans are recognized by UL and certified by DEMKO.

Standards

UL507, UL1917, CAN/CSA C22.2 No.113, EN60950

Installation Conditions for EN standards

Installation category

, Pollution degree 2, Class

equipment 

1

Varioflow Fans 

MRS18V2

type

OPERATING MANUAL

C

Содержание ORIX MRS18V2

Страница 1: ...ring operation please attach the following warning label so that it is clearly visible Warning label Do not touch the fan blades when the fan is in operation The use of the optional fingerguard is recommended to ensure protection Wegen der Verletzungsgefahr dürfen die Lüfterflügel bei Ventilatorbetrieb nicht berührt werden Der Gebrauch des als Sonderzubehör erhältlichen Fingerschutzes ist empfehle...

Страница 2: ...G CO LTD or other equivalent product or other equivalent product φ4 3mm min 9mm min 8mm max 9mm min 4 3mm min 8mm max 1 2 Line Ground Blue V R Blue Lead for connecting variable resistor 3 1 2 1 2 Line V R Ground Blue R1 R2 R3 Blue 1 2 3 Lead for connecting variable resistor 1 2 3 1 2 3 Ground terminal green M4 8 Terminal screws 2 M4 12 4 Installation Install the fan in locations that meet the foll...

Страница 3: ...Circuit damage may result Example of Variable Resistor Installation 3 Variable resistor unit Lead wire Lead wire Solder wrap lead around Soldered terminal Enlargement of Circular Area Heat shrink tube two to three times 50 60 40 70 80 90 30 20 10 100 0 Variable resistor Panel Cut Out drawing Insulation sheet Mounting panel Scale plate Nut Crown washer Knob Stop screw φ3 7 5 0 4 φ10 4 1 Mounting th...

Страница 4: ...SW1 Line Circuit breaker 1 2 Fan MRS18V2 1 2 4 3 E Noise filter SW1 Line Circuit breaker Variable resistor Using a variable resistor 1 2 Fan MRS18V2 Characteristics specifications and dimensions are subject to change without notice Please contact your nearest ORIENTAL MOTOR office for further information ORIENTAL MOTOR CO LTD Headquarters Tel 03 3835 0684 Fax 03 3835 1890 ORIENTAL MOTOR EUROPA Gmb...

Отзывы: