Speed Contr
ol S
y
st
ems
Intr
oduction
A
C
Input
BX
A
C
Input
BLF
A
C
Input
BLU
A
C
Input
FBL
DC Input
BLH
BHF
FE100/
FE200
ES01/
ES02
US
Installation
Br
ushless Mot
or S
y
st
ems
A
C
Mot
or S
y
st
ems
B-151
Characteristics B-143
/
Dimensions B-145
/
Connection and Operation B-150
/
Motor and Speed Controller Combinations B-154
RG
SPEED
POWER
ALARM
100-
115V
~
SD
SS
H
L
MB+
MB-
U
I-COM
V
W
L
N
NC
FG
CW
CCW
MO
NC
NC
SD
FREE
RST
TP
H
M
L
S-MON
ALM
O-COM
ORIENTAL MOTOR
OFF
ON
OFF
ON
OFF
ON
SW1 Clockwise direction
/stop switching input
SW2 Counterclockwise direction
/stop switching input
SW3 Speed-setting
switching input
OFF
ON
OFF
ON
ON
OFF
SW4 Slow down input
SW5 Electromagnetic brake release input
✽
3
SW6 Alarm reset input
Regeneration unit
thermal signal input
3
2
1
External DC voltage for output signal
24 VDC
0.1 A min.
U
B
✽
2
B
✽
2
V
W
Power supply
Circuit breaker
Power connection
Connect to a single-phase 100-115 VAC
±
10%,
50/60 Hz power supply.
(
FSP200-2
: Connect to a single-phase 200-230 VAC
±
10%,
50/60 Hz power supply.)
Protective Earth
(screw size: M4)
To TP
To I-COM
400
Ω
Regeneration unit
✽
1
[
EPRC-400P
(sold separately)]
+
−
Speed potentiometer
20 k
Ω
1/4 W
[
PAVR-20KZ
(sold separately)]
OFF
ON
OFF
ON
OFF
ON
SW1 Clockwise direction
/stop switching input
SW2 Counterclockwise direction
/stop switching input
SW3 Speed-setting
switching input
OFF
ON
OFF
ON
ON
OFF
SW4 Slow down input
SW6 Alarm reset input
Regeneration unit
thermal signal input
3
2
1
External DC voltage for output signal
24 VDC
0.1 A min.
U
B
✽
2
B
✽
2
V
W
Power supply
Circuit breaker
Power connection
Connect to a three-phase 200-230 VAC
±
10%,
50/60 Hz power supply.
Protective Earth
(screw size: M4)
RG
POWER
ALARM
200-
230V
~
H
L
MB+
MB-
U
I-COM
V
W
L1
L3
FG
CW
CCW
MO
NC
NC
SD
FREE
RST
TP
H
M
L
S-MON
ALM
O-COM
ORIENTAL MOTOR
L2
To TP
To I-COM
400
Ω
Regeneration unit
✽
1
[
EPRC-400P
(sold separately)]
−
+
SW5 Electromagnetic brake release input
✽
3
Speed potentiometer
20 k
Ω
1/4 W
[
PAVR-20KZ
(sold separately)]
SPEED
SD
SS
Connection Diagrams
●
Single-phase 100-115 VAC,
◇
Single-phase 200-230 VAC
Three-phase 200-230 VAC
◇
Refer to page A-298 for connection of the
●
SDM496
speed indicator.
1
✽
This should be connected only when using a regeneration unit.
2
✽
This should be connected only for a speed control motor and controller package with electromagnetic brake.
3
✽
The electromagnetic brake release input can be used only with a speed control motor and controller package with electromagnetic brake.
Notes:
When wiring the motor and the speed controller, keep a maximum distance of 50 m (164 ft.) or less. If the wiring between the motor and the speed controller needs to be extended by 10 m (32.8 ft.)
●
or more, use a polyethylene-insulated electric wire of AWG16 (1.25 mm
2
) or larger. Do not connect more than one cable or allow the overall wiring length to exceed 50 m (164 ft.). This may cause a
malfunction.
With the electromagnetic brake type, setting the wiring length too long delays the operation of the electromagnetic brake [by approx. 100 ms at a wiring length of 50 m (164 ft.)] . To minimize the
●
delay time, use separate cables for the electromagnetic brake and motor cable.
The signal wiring and motor cables should be kept away from noise-generating equipment or power lines.
●