3

Lead wire 

color

Pin No.

Signal name

Description

Purple-2

A17

HOMES

Mechanical home sensor input

Gray-2

A18

SLIT

Slit sensor input

White-2

A19

N.C.

Not used

Black-2

A20

IN-COM1

Sensor input common

 

Lower ribbon cable

Control output 1 to 4 settings can be changed using the “OUT1to OUT4 signal mode 
selection” parameters.

Lead wire 

color

Pin No.

Signal name

Description

Brown-3

B1

MOVE+

Motor moving output

Red-3

B2

MOVE−

Orange-3

B3

ALM+

Alarm output

Yellow-3

B4

ALM−

Green-3

B5

OUT1+

Control output 1 (initial value: AREA)

Blue-3

B6

OUT1−

Purple-3

B7

OUT2+

Control output 2 (initial value: READY)

Gray-3

B8

OUT2−

White-3

B9

OUT3+

Control output 3 (initial value: WNG)

Black-3

B10

OUT3−

Brown-4

B11

OUT4+

Control output 4 (initial value: HOME-P)

Red-4

B12

OUT4−

Orange-4

B13

N.C.

Not used

Yellow-4

B14

N.C.

Not used

Green-4

B15

PLS-OUT+

Pulse output (Line driver output)

Blue-4

B16

PLS-OUT−

Purple-4

B17

DIR-OUT+

Direction output (Line driver output)

Gray-4

B18

DIR-OUT−

White-4

B19

GND

GND

Black-4

B20

N.C.

Not used

 

„

CN4: Actuator connector

Connect using the supplied CN4 connector 
cable (5 pins).

Pin No.

Description

1

Blue motor lead

2

Red motor lead

3

Orange motor lead

4

Green motor lead

5

Black motor lead

 

„

CN6/7: RS-485 communication connector

Connect this cable if you want to control your product via RS-485 communication.

Pin No.

Signal name

Description

1

N.C.

Not used

2

GND

GND

3

TR+

RS-485 communication signal (+)

4

N.C.

Not used

5

N.C.

Not used

6

TR−

RS-485 communication signal (−)

7

N.C.

Not used

8

N.C.

Not used

Setting the switches

Be sure to turn off the driver power before setting the switches. If the 
switches are set while the power is still on, the new switch settings will not 
become effective until the driver power is cycled.

 

„

Address number

Set the address number using the 
address number setting switch (SW1) and 
“communication axis number” parameter.

Factory setting: 0 (address number 0)

Address number
setting switch (SW1)

SW1

Address number

SW1

Address number

0

0

8

8

1

1

9

9

2

2

A

10

3

3

B

11

4

4

C

12

5

5

D

13

6

6

E

14

7

7

F

Setting value of “communication  

axis number” parameter *

 

* The default value of the “communication axis number” parameter is “15.” Set the 

“communication axis number” parameter using the 

OPX-2A

 or 

MEXE02

.

 

„

Setting the connection destination

Set the connection destination of RS-485 communication using position No.4 of the 
function setting switch (SW2).

Factory setting: OFF (network converter)

SW2-No.4

Connection destination

Function setting
switch (SW2-No.4)

ON

General master device

OFF

Network converter

 

„

Baud rate

Set the baud rate using Nos. 1 to 3 of the 
function setting switch (SW2) to.

Factory setting: All ON (625,000 bps)

Function setting
switches
(SW2-Nos.1 to 3)

Baud rate (bps)

SW2-No.3

SW2-No.2

SW2-No.1

9600

OFF

OFF

OFF

19200

OFF

OFF

ON

38400

OFF

ON

OFF

57600

OFF

ON

ON

115,200

ON

OFF

OFF

250,000

ON

OFF

ON

312,500

ON

ON

OFF

625,000

ON

ON

ON

 

„

Termination resistor

Set the Termination resistor for RS-485 
communication (120 Ω) using the Termination 
resistor setting switch (SW3).

Factory setting: OFF  
(Termination resistor disabled)

ON

OFF

Terminal resistor
setting switch (SW3)

SW3

Termination resistor (120 Ω)

OFF

Disabled

ON

Enabled