Alarms
148
5 T
1
Alarms
This driver is equipped with the alarm function to protect from temperature rise, poor connection, error in operation,
and others.
If an alarm is generated, the ALM-A output is turned ON and the ALM-B output is turned OFF to stop the motor. The
PWR/ALM LED blinks in red simultaneously.
Details of the alarm being generated can be checked by counting the number of times the PWR/ALM LED blinks, via
EtherCAT communication, or using the
MEXE02
.
1-1
Alarm reset
Before resetting an alarm, always remove the cause of the alarm and ensure safety, and perform one of the reset
operations specified below.
•
Set the Fault reset (6040h: Bit 7) of Controlword to 1. (It is enabled when changing from 0 to 1.)
•
Turn the ALM-RST input ON. (It is enabled at the ON edge of the input.)
•
Execute the alarm reset using the
MEXE02
.
•
Turn off the main power supply and the control power supply, and on again.
•
Some alarms can be reset by only turning on the main power supply and control power supply
again. Refer to “1-4 Alarms list” on p.149.
•
An alarm of Absolute position error can be reset if the position preset (P-PRESET) or return-to-
home operation is performed. If it cannot be reset by these methods, the ABZO sensor may be
damaged.
1-2
Alarm history
Up to 10 generated alarm items are stored in the non-volatile memory in order of the latest to the oldest. The alarm
history stored in the non-volatile memory can be read or cleared if one of the following is performed.
•
Read the alarm history by the Alarm history (4041h to 404Ah) via EtherCAT communication.
•
Clear the alarm history by setting the Clear alarm history (40C2h) of EtherCAT communication to 1. (It is enabled
when changing from 0 to 1.)
•
Read or clear the alarm history using the
MEXE02
.
1-3
Generation condition of alarms
Alarms shown in the table will be generated if the generation condition is exceeded.
Alarm code
Alarm name
Motor model
Generation condition
21h
Main circuit overheat
−
85 °C (185 °F)
22h
Overvoltage
−
36 V *1
63 V *2
26h
Motor overheat
−
85 °C (185 °F)
31h
Overspeed
AZM14
,
AZM15, AZM24
,
AZM26
8,000 r/min
AZM46
,
AZM48
,
AZM66
4,500 r/min
AZM69
2,500 r/min
34h
Command pulse error
−
38,400 r/min
*1 When the Main power mode is 24 VDC.
*2 When the Main power mode is 48 VDC.